Simone Vincenzo Suraci

Dr. Simone Vincenzo Suraci

Laboratory of Innovative Materials for Electrical Systems (LIMES), Department of Electrical, Electronic and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2020 in IEEE Access
Verified
Journal Article
Open access
Simone Vincenzo SuraciSimone Vincenzo Suraci
Simone Vincenzo Suraci
Davide FabianiDavide Fabiani
Davide Fabiani
AXAnne Xu
Anne Xu
SRSebastien Roland
Sebastien Roland
Xavier COLINXavier COLIN
Xavier COLIN
This paper investigates the changes in electrical and physico-chemical properties of low-voltage power cables for nuclear application when subjected to the combined effects of gamma radiation and temperature. Electrical response is evaluated by means of the dielectric spectroscopy, while the physico-chemical changes are analyzed at different structural scales through five complementary techniques (OIT measurements, FTIR spectroscopy, swelling measurements, DSC analysis and micro-indentation). The dielectric spectroscopy and the first two chemical techniques are shown to be appropriate for evaluating the development of radio-thermal ageing in low-voltage cables. Hence, the results reported in this article suggest the effectiveness of dielectric spectroscopy as a non-destructive technique for on-site cable diagnosis.

4 February 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Davide FabianiDavide Fabiani
Davide Fabiani
Simone Vincenzo SuraciSimone Vincenzo Suraci
Simone Vincenzo Suraci
This paper deals with the study of a non-destructive technique to detect the aging state of cable insulation used in a nuclear environment subjected to radiation and temperature aging. Cable samples were aged under dose rates ranging from 0.42 and 1.06 kGy/h at 55 and 85 °C. The imaginary part of the permittivity at 100 kHz is found to correlate well with mechanical properties, such as elongation at break, which is typically used to diagnose cable insulation, but it is a destructive property and cannot be used on field. It has been demonstrated also that a post-irradiation effect occurs even years after aging is stopped, increasing the imaginary permittivity and worsening mechanical properties due to the slow conversion of radicals into oxidized species. The main consequence is that when cable insulation is subjected to a nuclear accident, releasing a huge amount of radiation, the health of cable insulation must be followed also for a long time after the accident occurred, since aging due to oxidation progresses even when the radiation source is switched off.

3 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
Simone Vincenzo SuraciSimone Vincenzo Suraci
Simone Vincenzo Suraci
Davide FabianiDavide Fabiani
Davide Fabiani
LMLaura Mazzocchetti
Laura Mazzocchetti
loris giorginiloris giorgini
loris giorgini
The usability of any material hinges upon its stability over time. One of the major concerns, focusing on polymeric materials, is the degradation they face during their service life. The degradation mechanisms are deeply influenced by the aging temperature to which the material is subjected. In this paper, low-density polyethylene (LDPE) flat specimens were thermally aged under two different temperatures (90 °C and 110 °C) and analyzed. Specimens were characterized through both the most common mechanical and chemical measurements techniques (e.g., tensile stress, thermal analyses, oxidation induction time) and electrical measurements (dielectric spectroscopy, in particular), which are examples of non-destructive techniques. As a result, a very spread characterization of the polyethylene-based materials was obtained and a very good correlation was found to exist between these different techniques, highlighting the possibility of following the aging degradation development of polymers through electrical non-destructive techniques.

7 June 2021 in IEEE Access
Verified
Journal Article
Open access
Simone Vincenzo SuraciSimone Vincenzo Suraci
Simone Vincenzo Suraci
Davide FabianiDavide Fabiani
Davide Fabiani
This article presents the development and application of a modelling approach based on quantities obtained from mechanical and electrical tests to assess the aging of low voltage cable insulation for nuclear applications. In order to obtain experimental data needed for the establishing of the models, accelerated aging is performed on coaxial cables. The first part of this paper focuses on the development of a predictive modelling for mechanical properties; this allows the evaluation of the Dose to Equivalent Damage (DED) as a function of the aging stress (dose rate). However, the use of mechanical tests for cable aging assessment presents some problems, being such tests destructive for the insulation and potentially affected by local defects. The novelty of this work lays on the introduction of a new model, allowing the definition of the end-of-life point in terms of electrical non-destructive tests. The second part of this article presents the development of aging modelling of cable insulation and correlation with experimental data obtained at different stresses, which allow the estimation of the expected life of the cable under test to be derived from diagnostic measurements of electrical properties like, e.g, tan δ. Finally, the application of the proposed life model to two typical real-condition nuclear environments is presented and discussed.

1 November 2021 in Polymer Testing
Verified
Journal Article
Open access
Simone Vincenzo SuraciSimone Vincenzo Suraci
Simone Vincenzo Suraci
DFDavide Fabiani
Davide Fabiani
SRSébastien Roland
Sébastien Roland
XCXavier Colin
Xavier Colin

16 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SHSarah Hettal
Sarah Hettal
Simone Vincenzo SuraciSimone Vincenzo Suraci
Simone Vincenzo Suraci
SRSébastien Roland
Sébastien Roland
Davide FabianiDavide Fabiani
Davide Fabiani
Xavier COLINXavier COLIN
Xavier COLIN
The radio-thermal ageing of silane-crosslinked polyethylene (Si-XLPE) was studied in air under different γ dose rates (6.0, 8.5, 77.8, and 400 Gy·h−1) at different temperatures (21, 47, and 86 °C). The changes in the physico-chemical and electrical properties of Si-XLPE throughout its exposure were determined using Fourier transform infrared spectroscopy coupled with chemical gas derivatization, hydrostatic weighing, differential scanning calorimetry, dielectric spectroscopy and current measurements under an applied electric field. From a careful analysis of the oxidation products, it was confirmed that ketones are the main oxidation products in Si-XLPE. The analytical kinetic model for radio-thermal oxidation was thus completed with relatively simple structure–property relationships in order to additionally predict the increase in density induced by oxidation, and the adverse changes in two electrical properties of Si-XLPE: the dielectric constant ε′ and volume resistivity R. After having shown the reliability of these new kinetic developments, the lifetime of Si-XLPE was determined using a dielectric end-of-life criterion deduced from a literature compilation on the changes in R with ε′ for common polymers. The corresponding lifetime was found to be at least two times longer than the lifetime previously determined with the conventional end-of-life criterion, i.e., the mechanical type, thus confirming the previous literature studies that had shown that fracture properties degrade faster than electrical properties.