chen zhenpeng

Mr. chen zhenpeng

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2020 in Electronics
Verified
Journal Article
Open access
PDF file
CZchen zhenpeng
chen zhenpeng
YZYuanjie Zheng
Yuanjie Zheng
XLXiaojie Li
Xiaojie Li
RLRong Luo
Rong Luo
Weikuan JiaWeikuan Jia
Weikuan Jia
CLChengjiang Li
Chengjiang Li
Image matting refers to the task of estimating the foreground of images, which is an important problem in image processing. Recently, trimap generation has attracted considerable attention because designing a trimap for every image is labor-intensive. In this paper, a two-step algorithm is proposed to generate trimaps. To use the proposed algorithm, users must only provide some clicks (foreground clicks and background clicks), which are employed as the input to generate a binary mask. One-shot learning technique achieves remarkable progress on semantic segmentation, we extend this technique to perform the binary mask prediction task. The mask is further used to predict the trimap using image dilation. Extensive experiments were performed to evaluate the proposed algorithm. Experimental results show that the trimaps generated using the proposed algorithm are visually similar to the user-annotated ones. Comparing with the interactive matting algorithms, the proposed algoritm is less labor-intensive than trimap-based matting algorithm and achieved more accuate results than scribble-based matting algorithm.

28 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YSYilu Shou
Yilu Shou
CZchen zhenpeng
chen zhenpeng
FPFeng Pujie
Feng Pujie
YWYanan Wei
Yanan Wei
BQBeier Qi
Beier Qi
HLHaiyun Li
Haiyun Li
Background: The rupture of intracranial aneurysms (IAs) would result in subarachnoid hemorrhage with high mortality and disability. Predicting the risk of IAs rupture remains a challenge. Methods: This paper proposed an effective method for classifying IAs rupture status by integrating a PointNet-based model and machine learning algorithms. First, medical image segmentation and reconstruction algorithms were applied to 3D Digital Subtraction Angiography (DSA) imaging data to construct three-dimensional IAs geometric models. Geometrical parameters of IAs were then acquired using Geomagic, followed by the computation of hemodynamic clouds and hemodynamic parameters using Computational Fluid Dynamics (CFD). A PointNet-based model was developed to extract different dimensional hemodynamic cloud features. Finally, five types of machine learning algorithms were applied on geometrical parameters, hemodynamic parameters, and hemodynamic cloud features to classify and recognize IAs rupture status. The classification performance of different dimensional hemodynamic cloud features was also compared. Results: The 16-, 32-, 64-, and 1024-dimensional hemodynamic cloud features were extracted with the PointNet-based model, respectively, and the four types of cloud features in combination with the geometrical parameters and hemodynamic parameters were respectively applied to classify the rupture status of IAs. The best classification outcomes were achieved in the case of 16-dimensional hemodynamic cloud features, the accuracy of XGBoost, CatBoost, SVM, LightGBM, and LR algorithms was 0.887, 0.857, 0.854, 0.857, and 0.908, respectively, and the AUCs were 0.917, 0.934, 0.946, 0.920, and 0.944. In contrast, when only utilizing geometrical parameters and hemodynamic parameters, the accuracies were 0.836, 0.816, 0.826, 0.832, and 0.885, respectively, with AUC values of 0.908, 0.922, 0.930, 0.884, and 0.921. Conclusion: In this paper, classification models for IAs rupture status were constructed by integrating a PointNet-based model and machine learning algorithms. Experiments demonstrated that hemodynamic cloud features had a certain contribution weight to the classification of IAs rupture status. When 16-dimensional hemodynamic cloud features were added to the morphological and hemodynamic features, the models achieved the highest classification accuracies and AUCs. Our models and algorithms would provide valuable insights for the clinical diagnosis and treatment of IAs.


27 April 2025 in Tomography
Verified
Journal Article
Open access
PDF file
HLHaoyan Li
Haoyan Li
CZchen zhenpeng
chen zhenpeng
SGShuaiyi Gao
Shuaiyi Gao
JHJiaqi Hu
Jiaqi Hu
ZYZhihao Yang
Zhihao Yang
JSJihang Sun
Jihang Sun
Objectives: To evaluate the medical image segmentation performance of monochromatic images in various energy levels. Methods: The low-density module (25 mm in diameter, 6 Hounsfield Unit (HU) in density difference from background) from the ACR464 phantom was scanned at both 10 mGy and 5 mGy dose levels. Virtual monoenergetic images (VMIs) at different energy levels of 40, 50, 60, 68, 74, and 100 keV were generated. The images at 10 mGy reconstructed with 50% adaptive statistical iterative reconstruction veo (ASIR-V50%) were used to train an image segmentation model based on U-Net. The evaluation set used 5 mGy VMIs reconstructed with various reconstruction algorithms: FBP, ASIR-V50%, ASIR-V100%, deep learning image reconstruction (DLIR) with low (DLIR-L), medium (DLIR-M), and high (DLIR-H) strength levels. U-Net was employed as a tool to compare algorithm performance. Image noise and segmentation metrics, such as the DICE coefficient, intersection over union (IOU), sensitivity, and Hausdorff distance, were calculated to assess both image quality and segmentation performance. Results: DLIR-M and DLIR-H consistently achieved lower image noise and better segmentation performance, with the highest results observed at 60 keV, and DLIR-H had the lowest image noise across all energy levels. The performance metrics, including IOU, DICE, and sensitivity, were ranked in descending order with energy levels of 60 keV, 68 keV, 50 keV, 74 keV, 40 keV, and 100 keV. Specifically, at 60 keV, the average IOU values for each reconstruction method were 0.60 for FBP, 0.67 for ASIR-V50%, 0.68 for ASIR-V100%, 0.72 for DLIR-L, 0.75 for DLIR-M, and 0.75 for DLIR-H. The average DICE values were 0.75, 0.80, 0.82, 0.83, 0.85, and 0.86. The sensitivity values were 0.93, 0.91, 0.96, 0.95, 0.98, and 0.98. Conclusions: For low-density, non-enhancing objects under a low dose, the 60 keV VMIs performed better in automatic segmentation. DLIR-M and DLIR-H algorithms delivered the best results, whereas DLIR-H provided the lowest image noise and highest sensitivity.

22 November 2024 in Journal of Alzheimer’s Disease
Verified
Journal Article
Closed access
CZchen zhenpeng
chen zhenpeng
BQBeier Qi
Beier Qi
BJBin Jing
Bin Jing
RDRuijuan Dong
Ruijuan Dong
RCRong Chen
Rong Chen
HLHaiyun Li
Haiyun Li
Background: Accurately differentiating stable mild cognitive impairment (sMCI) from progressive MCI (pMCI) is clinically relevant, and identification of pMCI is crucial for timely treatment before it evolves into Alzheimer's disease (AD). Objective: To construct a convolutional neural network (CNN) model to differentiate pMCI from sMCI integrating features from structural magnetic resonance imaging (sMRI) and positron emission tomography (PET) images. Methods: We proposed a multi-modal and multi-stage region of interest (ROI)-based fusion network (m2ROI-FN) CNN model to differentiate pMCI from sMCI, adopting a multi-stage fusion strategy to integrate deep semantic features and multiple morphological metrics derived from ROIs of sMRI and PET images. Specifically, ten AD-related ROIs of each modality images were selected as patches inputting into 3D hierarchical CNNs. The deep semantic features extracted by the CNNs were fused through the multi-modal integration module and further combined with the multiple morphological metrics extracted by FreeSurfer. Finally, the multilayer perceptron classifier was utilized for subject-level MCI recognition. Results: The proposed model achieved accuracy of 77.4% to differentiate pMCI from sMCI with 5-fold cross validation on the entire ADNI database. Further, ADNI-1&2 were formed into an independent sample for model training and validation, and ADNI-3&GO were formed into another independent sample for multi-center testing. The model achieved 73.2% accuracy in distinguishing pMCI and sMCI on ADNI-1&2 and 75% accuracy on ADNI-3&GO. Conclusions: An effective m2ROI-FN model to distinguish pMCI from sMCI was proposed, which was capable of capturing distinctive features in ROIs of sMRI and PET images. The experimental results demonstrated that the model has the potential to differentiate pMCI from sMCI.

10 July 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
CZchen zhenpeng
chen zhenpeng
MLMingming Li
Mingming Li
SLShuang Li
Shuang Li
KWKang Wang
Kang Wang
HLHaiyun Li
Haiyun Li
Fundus fluorescein angiography (FFA) is the gold standard for diabetic retinopathy (DR) staging, yet whether angiographic phase affects deep learning performance remains unknown. Using 7508 FFA images from 863 eyes, stratified into venous, recirculation, and late phases, we developed Swin Transformer- and ConvNeXt-based DR staging models under the International five-grade and Chinese six-grade classification systems. Multiclass and binary (NPDR vs. PDR) classification tasks were evaluated. This study provides the first systematic quantification of angiographic phase effects on FFA-based DR staging. Phase-related performance was analyzed using generalized linear mixed-effects models with beta regression. ConvNeXt generally outperformed Swin Transformer, particularly in multiclass classification. Across all experimental settings, performance showed a consistent numerical decline from the venous to the late phase. Under the International five-grade system, ConvNeXt accuracy declined from 86.67% to 81.87%; however, Bonferroni-adjusted comparisons revealed no statistically significant phase-related differences (all adjusted p > 0.05), with small effect sizes (|SMD| < 0.2). Binary classification remained highly stable across phases, with accuracies exceeding 91%. Grad-CAM visualizations demonstrated progressively diffuse model attention in later phases. These findings support phase-flexible FFA acquisition for binary DR screening, whereas venous- or recirculation-phase images remain preferable for high-precision multiclass staging, guiding phase-aware AI development.