Yilu Shou

Ms. Yilu Shou

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YSYilu Shou
Yilu Shou
CZchen zhenpeng
chen zhenpeng
FPFeng Pujie
Feng Pujie
YWYanan Wei
Yanan Wei
BQBeier Qi
Beier Qi
HLHaiyun Li
Haiyun Li
Background: The rupture of intracranial aneurysms (IAs) would result in subarachnoid hemorrhage with high mortality and disability. Predicting the risk of IAs rupture remains a challenge. Methods: This paper proposed an effective method for classifying IAs rupture status by integrating a PointNet-based model and machine learning algorithms. First, medical image segmentation and reconstruction algorithms were applied to 3D Digital Subtraction Angiography (DSA) imaging data to construct three-dimensional IAs geometric models. Geometrical parameters of IAs were then acquired using Geomagic, followed by the computation of hemodynamic clouds and hemodynamic parameters using Computational Fluid Dynamics (CFD). A PointNet-based model was developed to extract different dimensional hemodynamic cloud features. Finally, five types of machine learning algorithms were applied on geometrical parameters, hemodynamic parameters, and hemodynamic cloud features to classify and recognize IAs rupture status. The classification performance of different dimensional hemodynamic cloud features was also compared. Results: The 16-, 32-, 64-, and 1024-dimensional hemodynamic cloud features were extracted with the PointNet-based model, respectively, and the four types of cloud features in combination with the geometrical parameters and hemodynamic parameters were respectively applied to classify the rupture status of IAs. The best classification outcomes were achieved in the case of 16-dimensional hemodynamic cloud features, the accuracy of XGBoost, CatBoost, SVM, LightGBM, and LR algorithms was 0.887, 0.857, 0.854, 0.857, and 0.908, respectively, and the AUCs were 0.917, 0.934, 0.946, 0.920, and 0.944. In contrast, when only utilizing geometrical parameters and hemodynamic parameters, the accuracies were 0.836, 0.816, 0.826, 0.832, and 0.885, respectively, with AUC values of 0.908, 0.922, 0.930, 0.884, and 0.921. Conclusion: In this paper, classification models for IAs rupture status were constructed by integrating a PointNet-based model and machine learning algorithms. Experiments demonstrated that hemodynamic cloud features had a certain contribution weight to the classification of IAs rupture status. When 16-dimensional hemodynamic cloud features were added to the morphological and hemodynamic features, the models achieved the highest classification accuracies and AUCs. Our models and algorithms would provide valuable insights for the clinical diagnosis and treatment of IAs.


22 November 2024 in Journal of Alzheimer’s Disease
Verified
Journal Article
Closed access
CZchen zhenpeng
chen zhenpeng
BQBeier Qi
Beier Qi
BJBin Jing
Bin Jing
RDRuijuan Dong
Ruijuan Dong
RCRong Chen
Rong Chen
HLHaiyun Li
Haiyun Li
Background: Accurately differentiating stable mild cognitive impairment (sMCI) from progressive MCI (pMCI) is clinically relevant, and identification of pMCI is crucial for timely treatment before it evolves into Alzheimer's disease (AD). Objective: To construct a convolutional neural network (CNN) model to differentiate pMCI from sMCI integrating features from structural magnetic resonance imaging (sMRI) and positron emission tomography (PET) images. Methods: We proposed a multi-modal and multi-stage region of interest (ROI)-based fusion network (m2ROI-FN) CNN model to differentiate pMCI from sMCI, adopting a multi-stage fusion strategy to integrate deep semantic features and multiple morphological metrics derived from ROIs of sMRI and PET images. Specifically, ten AD-related ROIs of each modality images were selected as patches inputting into 3D hierarchical CNNs. The deep semantic features extracted by the CNNs were fused through the multi-modal integration module and further combined with the multiple morphological metrics extracted by FreeSurfer. Finally, the multilayer perceptron classifier was utilized for subject-level MCI recognition. Results: The proposed model achieved accuracy of 77.4% to differentiate pMCI from sMCI with 5-fold cross validation on the entire ADNI database. Further, ADNI-1&2 were formed into an independent sample for model training and validation, and ADNI-3&GO were formed into another independent sample for multi-center testing. The model achieved 73.2% accuracy in distinguishing pMCI and sMCI on ADNI-1&2 and 75% accuracy on ADNI-3&GO. Conclusions: An effective m2ROI-FN model to distinguish pMCI from sMCI was proposed, which was capable of capturing distinctive features in ROIs of sMRI and PET images. The experimental results demonstrated that the model has the potential to differentiate pMCI from sMCI.