Marie Pospíšilová

Dr. Marie Pospíšilová

Ceské vysoké ucení technické v Praze, Prague, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MPMarie Pospíšilová
Marie Pospíšilová
GKGabriela Kuncova
Gabriela Kuncova
JTJosef Trögl
Josef Trögl
This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 μm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.

1 January 2016 in Chemical Papers
Verified
Journal Article
Closed access
JZJakub Zajic
Jakub Zajic
MBMilan Bittner
Milan Bittner
Tomáš BrányikTomáš Brányik
Tomáš Brányik
ASAndrey Solovyev
Andrey Solovyev
SŠStanislav Šabata
Stanislav Šabata
MPMarie Pospíšilová
Marie Pospíšilová

1 July 1998 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MPMarie Pospíšilová
Marie Pospíšilová
MPM Polášek
M Polášek
VJV Jokl
V Jokl

6 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JZJakub Zajíc
Jakub Zajíc
SRSteven Ripp
Steven Ripp
JTJosef Trögl
Josef Trögl
GKGabriela Kuncova
Gabriela Kuncova
MPMarie Pospíšilová
Marie Pospíšilová
In this study, we show the repetitive detection of toluene on a tapered optical fiber element (OFE) with an attached layer of Pseudomonas putida TVA8 bioluminescent bioreporters. The bioluminescent cell layer was attached on polished quartz modified with (3-aminopropyl)triethoxysilane (APTES). The repeatability of the preparation of the optical probe and its use was demonstrated with five differently shaped OFEs. The intensity of measured bioluminescence was minimally influenced by the OFE shape, possessing transmittances between 1.41% and 5.00%. OFE probes layered with P. putida TVA8 were used to monitor liquid toluene over a two-week period. It was demonstrated that OFE probes layered with positively induced P. putida TVA8 bioreporters were reliable detectors of toluene. A toluene concentration of 26.5 mg/L was detected after <30 min after immersion of the probe in the toluene solution. Additional experiments also immobilized constitutively bioluminescent cells of E. coli 652T7, on OFEs with polyethyleneimine (PEI). These OFEs were repetitively induced with Lauria-Bertani (LB) nutrient medium. Bioluminescence appeared 15 minutes after immersion of the OFE in LB. A change in pH from 7 to 6 resulted in a decrease in bioluminescence that was not restored following additional nutrient inductions at pH 7. The E. coli 652T7 OFE probe was therefore sensitive to negative influences but could not be repetitively used.

1 July 2019
Verified
Conference Paper
Closed access
JZJakub Zajíc
Jakub Zajíc
SRSteven Ripp
Steven Ripp
JTJosef Trögl
Josef Trögl
GKGabriela Kuncova
Gabriela Kuncova
MPMarie Pospíšilová
Marie Pospíšilová
A whole-cell optical fiber sensor of toluene was prepared by the adsorption of Pseudomonas putida TVA8, the bacterial strain producing light in contact with toluene, in the form of biofilm. Bioreporter immobilization was facilitated by (3-Aminopropyl)triethoxysilane (APTES) treatment on the wider end of tapered quartz optical fiber element (OFE). Repeatability of preparation and response of the active part of the biosensor was demonstrated in five trials with different OFE geometries in which the bioluminescence (BL) was induced with toluene solution (26.5 mg L −1 ) for 2 weeks. Longevity of inductions of the biosensor was shown in over 135 days trial, when the biosensor was repetitively induced with toluene solution (26.5 mg L −1 ) 68 times. The intensities of BL gradually decreased due to release of the adsorbed cells and they were only temporarily restored by the addition of nutrients. The intensities of BL induced with contaminated ground water were lower than in the mineral medium (MSM) with the same content of toluene. Ideal shape of OFE, which maximizes the detected signal, was calculated to be a Frustrum cone. The developed sensor is plausible for multiple and fast online monitoring of the presence of a pollutant in remote localities but not its concentration.

11 February 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MPMarie Pospíšilová
Marie Pospíšilová
HKHana Kalabova
Hana Kalabova
GKGabriela Kuncova
Gabriela Kuncova
In this paper, we analysed the steady state fluorescence spectra of cell suspensions containing healthy and carcinoma fibroblast mouse cells, using a genetic-algorithm-spectra-decomposition software (GASpeD). In contrast to other deconvolution algorithms, such as polynomial or linear unmixing software, GASpeD takes into account light scatter. In cell suspensions, light scatter plays an important role as it depends on the number of cells, their size, shape, and coagulation. The measured fluorescence spectra were normalized, smoothed and deconvoluted into four peaks and background. The wavelengths of intensities’ maxima of lipopigments (LR), FAD, and free/bound NAD(P)H (AF/AB) of the deconvoluted spectra matched published data. In deconvoluted spectra at pH = 7, the fluorescence intensities of the AF/AB ratio in healthy cells was always higher in comparison to carcinoma cells. In addition, the AF/AB ratio in healthy and carcinoma cells were influenced differently by changes in pH. In mixtures of healthy and carcinoma cells, AF/AB decreases when more than 13% of carcinoma cells are present. Expensive instrumentation is not required, and the software is user friendly. Due to these attributes, we hope that this study will be a first step in the development of new cancer biosensors and treatments with the use of optical fibers.