WAQAR AHMAD KHAN

Dr. WAQAR AHMAD KHAN

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BRBilawal Rehman
Bilawal Rehman
ARATIQ UR REHMAN
ATIQ UR REHMAN
WKWAQAR AHMAD KHAN
WAQAR AHMAD KHAN
Irfan SamiIrfan Sami
Irfan Sami
Jongsuk RoJongsuk Ro
Jongsuk Ro
This paper presents a detailed analysis of commutation failure, AC/DC power flow, and voltage stability of multi-infeed high-voltage direct current (HVDC). The use of HVDC power transmission technology has become common in modern power systems. During the past two decades, HVDC technology has been extensively used for long-distance bulk power transmission to remote areas. Throughout the world, the demand for power has drastically increased in recent years due to industrialization; such situations make HVDC an economic candidate because the distance between power generation plants and load areas is significantly very long. The line-commutated converter (LCC) technology-based HVDC system is well more mature than other available conversion schemes (i.e., voltage source converters), and it is widely used in high-power projects. China had approximately 50 HVDC–LCC links in 2020, and a single LCC-based link with the highest capacity is 12 GW. The installation of several HVDC links in an existing power network has led to a situation where two or more HVDC links terminate in the electric vicinity of each other’s AC network or even in same AC busbar. Such scenarios are termed multi-infeed HVDC system. Multi-infeed HVDC systems bring various challenges related to voltage stability, local and concurrent commutation failure, and AC/DC power flow. Here, the literature available on these phenomena of LCC-based HVDC is discussed for future research. The assumptions and drawbacks of various techniques used for investigating the mentioned phenomena are also highlighted.

24 October 2019 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
WKWAQAR AHMAD KHAN
WAQAR AHMAD KHAN
TBTianshu Bi
Tianshu Bi
KJKe Jia
Ke Jia
Statistics shows that transients produced by lightning or momentary links with external objects, have produced more than 80% of faults in overhead lines. Reclosing of circuit breaker (CB) after a pre-defined dead time is very common however reclosing onto permanent faults may damage the power system stability and aggravate severe damage to the system. Thus, adaptive single-phase auto-reclosing (ASPAR) based on investigating existing electrical signals has fascinated engineers and researchers. An ASPAR blocks CB reclosing onto permanent faults and allows reclosing permission once secondary arc is quenched. To address the subject, there have been many ASPARs techniques proposed based on the features trapped in a faulty phase. This paper presents a critical survey of adaptive auto-reclosing schemes that have hitherto been applied to EHV transmission lines.

1 October 2018
Verified
Conference Paper
Closed access
WKWAQAR AHMAD KHAN
WAQAR AHMAD KHAN
TBTianshu Bi
Tianshu Bi
This paper proposes an adaptive single phase auto reclosing scheme for EHV transmission lines using continuous wavelet transform (CWT). The CWT extract features from the faulted phase voltage waveform. The wavelet coefficients obtained by CWT can provide an effective signal representation of the voltage at the faulty phase. An index is derived by the sum of the energy of CWT coefficients. By assessing the index, temporary and permanent faults can be identified. In case of temporary fault, arc extinction instant can also be determined, which is used by protective relay to prompt auto reclosing signal. The reliability of the proposed algorithm is tested well under a diversity of fault conditions on a 500 kV, 320 km long overhead line using MATLAB/Simulink.