Lupo Emanuela

Dr. Lupo Emanuela


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MMMonica Moroni
Monica Moroni
Alessandro MeiAlessandro Mei
Alessandro Mei
ALAlessandra Leonardi
Alessandra Leonardi
LELupo Emanuela
Lupo Emanuela
FMFloriana La Marca
Floriana La Marca
Traditional plants for plastic separation in homogeneous products employ material physical properties (for instance density). Due to the small intervals of variability of different polymer properties, the output quality may not be adequate. Sensing technologies based on hyperspectral imaging have been introduced in order to classify materials and to increase the quality of recycled products, which have to comply with specific standards determined by industrial applications. This paper presents the results of the characterization of two different plastic polymers—polyethylene terephthalate (PET) and polyvinyl chloride (PVC)—in different phases of their life cycle (primary raw materials, urban and urban-assimilated waste and secondary raw materials) to show the contribution of hyperspectral sensors in the field of material recycling. This is accomplished via near-infrared (900–1700 nm) reflectance spectra extracted from hyperspectral images acquired with a two-linear-spectrometer apparatus. Results have shown that a rapid and reliable identification of PET and PVC can be achieved by using a simple two near-infrared wavelength operator coupled to an analysis of reflectance spectra. This resulted in 100% classification accuracy. A sensor based on this identification method appears suitable and inexpensive to build and provides the necessary speed and performance required by the recycling industry.

1 May 2016 in Waste Management
Verified
Journal Article
Closed access
LELupo Emanuela
Lupo Emanuela
MMMonica Moroni
Monica Moroni
FMFloriana La Marca
Floriana La Marca
SFSimone Fulco
Simone Fulco
VPValentina Pinzi
Valentina Pinzi

23 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Patrizia PiroPatrizia Piro
Patrizia Piro
MPMichele Porti
Michele Porti
SVSimone Veltri
Simone Veltri
LELupo Emanuela
Lupo Emanuela
MMMonica Moroni
Monica Moroni
In urban and industrial environments, the constant increase of impermeable surfaces has produced drastic changes in the natural hydrological cycle. Decreasing green areas not only produce negative effects from a hydrological-hydraulic perspective, but also from an energy point of view, modifying the urban microclimate and generating, as shown in the literature, heat islands in our cities. In this context, green infrastructures may represent an environmental compensation action that can be used to re-equilibrate the hydrological and energy balance and reduce the impact of pollutant load on receiving water bodies. To ensure that a green infrastructure will work properly, vegetated areas have to be continuously monitored to verify their health state. This paper presents a ground spectroscopy monitoring survey of a green roof installed at the University of Calabria fulfilled via the acquisition and analysis of hyperspectral data. This study is part of a larger research project financed by European Structural funds aimed at understanding the influence of green roofs on rainwater management and energy consumption for air conditioning in the Mediterranean area. Reflectance values were acquired with a field-portable spectroradiometer that operates in the range of wavelengths 350–2500 nm. The survey was carried out during the time period November 2014–June 2015 and data were acquired weekly. Climatic, thermo-physical, hydrological and hydraulic quantities were acquired as well and related to spectral data. Broadband and narrowband spectral indices, related to chlorophyll content and to chlorophyll–carotenoid ratio, were computed. The two narrowband indices NDVI705 and SIPI turned out to be the most representative indices to detect the plant health status.

29 October 2013 in Sensors
Verified
Journal Article
Open access
PDF file
MMMonica Moroni
Monica Moroni
LELupo Emanuela
Lupo Emanuela
ACAntonio Cenedese
Antonio Cenedese
Recent developments in hardware and software have increased the possibilities and reduced the costs of hyperspectral proximal sensing. Through the analysis of high resolution spectroscopic measurements at the laboratory or field scales, this monitoring technique is suitable for quantitative estimates of biochemical and biophysical variables related to the physiological state of vegetation. Two systems for hyperspectral imaging have been designed and developed at DICEA-Sapienza University of Rome, one based on the use of spectrometers, the other on tunable interference filters. Both systems provide a high spectral and spatial resolution with low weight, power consumption and cost. This paper describes the set-up of the tunable filter platform and its application to the investigation of the environmental status of the region crossed by the Sacco river (Latium, Italy). This was achieved by analyzing the spectral response given by tree samples, with roots partly or wholly submerged in the river, located upstream and downstream of an industrial area affected by contamination. Data acquired is represented as reflectance indices as well as reflectance values. Broadband and narrowband indices based on pigment content and carotenoids vs. chlorophyll content suggest tree samples located upstream of the contaminated area are ‘healthier’ than those downstream.

1 August 2017 in Waste Management
Verified
Journal Article
Closed access
MMMonica Moroni
Monica Moroni
LELupo Emanuela
Lupo Emanuela
FMFloriana La Marca
Floriana La Marca

2 May 2018 in Separations
Verified
Journal Article
Open access
PDF file
MMMonica Moroni
Monica Moroni
LELupo Emanuela
Lupo Emanuela
VPValerio Della Pelle
Valerio Della Pelle
APAlessandra Pomponi
Alessandra Pomponi
FMFloriana La Marca
Floriana La Marca
The separation process within a mechanical recycling plant plays a major role in the context of the production of high-quality secondary raw materials and the reduction of extensive waste disposal in landfills. Traditional plants for plastic separation employ dry or wet processes that rely on the different physical properties among the polymers. The hydraulic separator is a device employing a wet technology for particle separation. It allows the separation of two-polymer mixtures into two products, one collected within the instrument and the other one expelled through its outlet ducts. Apparatus performance were analyzed as a function of fluid and solid flow rates, flow patterns developing within the apparatus, in addition to the density, shape, and size of the polymers. For the hydraulic configurations tested, a two-way coupling takes place where the fluid exerts an influence on the plastic particles and the opposite occurs too. The interaction between the solid and liquid phases determines whether a certain polymer settles within the device or is expelled from the apparatus. Tests carried out with samples of increasing volumes of solid particles demonstrate that there are no significant differences in the apparatus effectiveness as far as a two-way interaction takes place. Almost pure concentrates of Polyethylene Terephthalate (PET), Polyvinyl Chloride (PVC), and Polycarbonate (PC) can be obtained from a mixture of traditional polymers. Tests conducted on Polylactic Acid (PLA) and Mater-Bi® samples showed that the hydraulic separator can be effectively employed to separate bio-plastics from conventional plastics with remarkable grade and recovery.