More information is needed on the disinfection efficacy of chlorine for viruses in source water. In this study, chlorine disinfection efficacy was investigated for USEPA Contaminant Candidate List viruses coxsackievirus B5 (CVB5), echovirus 1 (E1), murine norovirus (MNV), and human adenovirus 2 (HAdV2) in one untreated groundwater source and two partially treated surface waters. Disinfection experiments using pH 7 and 8 source water were carried out in duplicate, using 0.2 and 1 mg/liter free chlorine at 5 and 15°C. The efficiency factor Hom (EFH) model was used to calculate disinfectant concentration × contact time (CT) values (mg·min/liter) required to achieve 2-, 3-, and 4-log 10 reductions in viral titers. In all water types, chlorine disinfection was most effective for MNV, with 3-log 10 CT values at 5°C ranging from ≤0.020 to 0.034. Chlorine disinfection was least effective for CVB5 in all water types, with 3-log 10 CT values at 5°C ranging from 2.3 to 7.9. Overall, disinfection proceeded faster at 15°C and pH 7 for all water types. Inactivation of the study viruses was significantly different between water types, but no single source water had consistently different inactivation rates than another. CT values for CVB5 in one type of source water exceeded the recommended CT values set forth by USEPA's Guidance Manual for Compliance with the Filtration and Disinfection Requirements for Public Water Systems using Surface Water Sources . The results of this study demonstrate that water quality plays a substantial role in the inactivation of viruses and should be considered when developing chlorination plans.
In this study, hollow-fiber ultrafiltration (UF) was assessed for recovery of Escherichia coli, Clostridium perfringens spores, Cryptosporidium parvum oocysts, echovirus 1, and bacteriophages MS2 and ΦX174 from ground and surface waters. Microbes were seeded into twenty-two 50-L water samples that were collected from the Southeastern United States and concentrated to ~500 mL by UF. Secondary concentration was performed for C. parvum by centrifugation followed by immunomagnetic separation. Secondary concentration for viruses was performed using centrifugal ultrafilters or polyethylene glycol precipitation. Nine water quality parameters were measured in each water sample to determine whether water quality data correlated with UF and secondary concentration recovery efficiencies. Average UF recovery efficiencies were 66%–95% for the six enteric microbes. Average recovery efficiencies for the secondary concentration methods were 35%–95% for C. parvum and the viruses. Overall, measured water quality parameters were not significantly associated with UF recovery efficiencies. However, recovery of ΦX174 was negatively correlated with turbidity. The recovery data demonstrate that UF can be an effective method for concentrating diverse microbes from ground and surface waters. This study highlights the utility of tangential-flow hollow fiber ultrafiltration for recovery of bacteria, viruses, and parasites from large volume environmental water samples.
The recent increase of reported cyclosporiasis outbreaks associated with fresh produce has highlighted the need for understanding environmental transmission of Cyclospora cayetanensis in agricultural settings and facilities. Conducting such environmental investigations necessitates robust sample collection and analytical methods to detect C. cayetanensis in water samples. This study evaluated three sample collection methods for recovery of C. cayetanensis oocysts from water samples during seeded recovery experiments. Two filtration-based methods, dead-end ultrafiltration (DEUF) and USEPA Method 1623.1, were evaluated for oocyst recovery from irrigation water. A non-filter-based method, continuous flow centrifugation (CFC), was evaluated separately for recovery from creek water and spent produce wash water. Median C. cayetanensis recovery efficiencies were 17% for DEUF and 16–22% for Method 1623.1. The DEUF method proved to be more robust than Method 1623.1, as the recovery efficiencies were less variable and the DEUF ultrafilters were capable of filtering larger volumes of high-turbidity water without clogging. Median C. cayetanensis recovery efficiencies for CFC were 28% for wash water and 63% for creek water, making it a viable option for processing water with high turbidity or organic matter. The data from this study demonstrate the capability of DEUF and CFC as filter-based and non-filter-based options, respectively, for the recovery of C. cayetanensis oocysts from environmental and agricultural waters.