Joint torque prediction plays an important role in quantitative limb rehabilitation assessment and exoskeleton robot, and it is essential to acquire feedback or feedforward signal for adaptive functional electrical stimulation (FES) control. The Surface electromyography (sEMG) signal is one of the basic processing techniques to detect muscle activity, and also one favorable technique to estimate joint torque. In order to predict joint torque in a wide range of real time convenient applications, it is necessary to fuse sEMG signals with other convenient physical sensors such as accelerometers and gyroscopes, herein, we use a time delay artificial neural network to predict human joint force of ankle eversion and inversion based on sEMG and angular velocity signals. We testify our method on the data recorded from 8 subjects (5 healthy subjects and 3 patients) who are on isokinetic ankle eversion and inversion. The results show that the mean Cross-correlation coefficients (ρ) and the mean normalized root-mean-square deviation (NRMSE %) calculated between the prediction and the real value for isokinetic contraction is 0.966±0.019 and 7.9% ±0.026. Compared with artificial neural network (ANN) and support vector regression (SVR), the proposed method can predict the joint torque effectively. For the future application, the method has the potential to be employed to predict the ankle moments in real-time application for quantitative lower limb rehabilitation assessment and exoskeleton robot control.
Fluorescence immunochromatographic assay (FICA) is a rapid immunoassay technique that has the characteristics of high precision and sensitivity. Although image FICA strip readers have the advantages of high portability and easy operation, the use of high-precision complementary metal oxide semiconductor (CMOS) image sensors leads to an increase in overall cost. Considering the popularity of CMOS image sensors in smartphones and their powerful processing functions, this work developed a smartphone-based FICA strip reader. An optical module suitable for the test strips with different fluorescent markers was designed by replacing the excitation light source and the light filter. An android smartphone was used for image acquisition and image denoising. Then, the test and control lines of the test strip image were recognized by the sliding window algorithm. Finally, the characteristic value of the strip image was calculated. A linear detection range from 10 to 5000 mIU/mL (R2 = 0.95) was obtained for human chorionic gonadotrophin with the maximum relative error less than 9.41%, and a linear detection range from 5 to 4000 pg/mL (R2 = 0.99) was obtained for aflatoxin B1, with the maximum relative error less than 12.71%. Therefore, the smartphone-based FICA strip reader had high portability, versatility, and accuracy.
As an emerging technology, fluorescence immunochromatographic assay (FICA) has the advantages of high sensitivity, strong stability and specificity, which is widely used in the fields of medical testing, food safety and environmental monitoring. The FICA reader based on image processing meets the needs of point-of-care testing because of its simple operation, portability and fast detection speed. However, the image gray level of common image sensors limits the detection range of the FICA reader, and high-precision image sensors are expensive, which is not conducive to the popularization of the instrument. In this paper, FICA strips’ image was collected using a common complementary metal oxide semiconductor (CMOS) image sensor and a range adjustment mechanism was established to automatically adjust the exposure time of the CMOS image sensor to achieve the effect of range expansion. The detection sensitivity showed a onefold increase, and the upper detection limit showed a twofold increase after the proposed method was implemented. In addition, in the experiments of linearity and accuracy, the fitting degree (R2) of the fitted curves both reached 0.999. Therefore, the automatic range adjustment method can obviously improve the detection range of the FICA reader based on image processing.
1 September 2021 in Journal of Physics: Conference Series
Surface electromyographic (sEMG) signal contains abundant information such as joint torque and joint motion, which is widely used in human-computer interactive intelligent rehabilitation equipment. In this work, the ankle torque of lower limb is taken as the research object, and the feature parameters of sEMG which represent the fatigue state are analysed. Advance prediction of fatigue features for specific time periods was performed using a normalized minimum average square (NLMS) filter. While the modified cerebellar model neural network (WFCMNN) is used to classify fatigue, which can be divided into three states, namely no fatigue, transition to fatigue, and fatigue. The results show that the accuracy of classification is 96.429%, which is better than other advanced models. At the same time, sEMG signal is used to predict fatigue in advance, which can solve the problem of differences between different individuals. Such strategy is helpful for doctors and physiotherapists to carry out rehabilitation treatment for patients, as a pre judgment and diagnosis index.
A fault diagnosis method based on wavelet and AR model SVM is proposed, and the vibration signal of fault bearing (model 6205-2RS JEM SKF) is analyzed. Firstly, the rolling bearing vibration signal is wavelet transformed, and the wavelet coefficients of each layer are extracted by transformation. Then, the AR model is established for each layer of wavelet coefficients. Finally, the parameters of the autoregressive model are input into the SVM classifier as feature vectors. The fault type of rolling bearing is identified by SVM classifier. The experimental results verify the effectiveness of the method