Khusnul Ain

Dr. Khusnul Ain

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
OROsmalina Nur Rahma
Osmalina Nur Rahma
APAlfian Pramudita Putra
Alfian Pramudita Putra
ARAkif Rahmatillah
Akif Rahmatillah
YPYang Sa’aDa Kamila Ariyansah Putri
Yang Sa’aDa Kamila Ariyansah Putri
NFNuzula Dwi Fajriaty
Nuzula Dwi Fajriaty
RCRifai Chai
Rifai Chai
Stress can lead to harmful conditions in the body, such as anxiety disorders and depression. One of the promising noninvasive methods, which has been widely used in detecting stress and emotion, is electrodermal activity (EDA). EDA has a tonic and phasic component called skin conductance level and skin conductance response (SCR). However, the components of the EDA cannot be directly extracted and need to be deconvolved to obtain it. The EDA signals were collected from 18 healthy subjects that underwent three sessions – Stroop test with increasing stress levels. The EDA signals were then deconvoluted by using continuous deconvolution analysis (CDA) and convex optimization approach to electrodermal activity (cvxEDA). Four features from the result of the deconvolution process were collected, namely sample average, standard deviation, first absolute difference, and normalized first absolute difference. Those features were used as the input of the classification process using the extreme learning machine (ELM). The output of classification was the stress level; mild, moderate, and severe. The visual of the phasic component using cvxEDA is more precise or smoother than the CDA's result. However, both methods could separate SCR from the original skin conductivity raw and indicate the small peaks from the SCR. The classification process results showed that both CDA and cvxEDA methods with 50 hidden layers in ELM had a high accuracy in classifying the stress level, which was 95.56% and 94.45%, respectively. This study developed a stress level classification method using ELM and the statistical features of SCR. The result showed that EDA could classify the stress level with over 94% accuracy. This system could help people monitor their mental health during overworking, leading to anxiety and depression because of untreated stress.

30 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ISImam Sapuan
Imam Sapuan
MYMoh. Yasin
Moh. Yasin
KAKhusnul Ain
Khusnul Ain
RARetna Apsari
Retna Apsari
This research offers a method for separating the components of tissue impedance, namely resistance and capacitive reactance. Two objects that have similar impedance or low contrast can be improved through separating the real and imaginary images. This method requires an Electrical Impedance Tomography (EIT) device. EIT can obtain potential data and the phase angle between the current and the potential measured. In the future, the device is very suitable for imaging organs in the thorax and abdomen that have the same impedance but different resistance and capacitive reactance. This device consists of programmable generators, Voltage Controlled Current Source (VCCS), mulptiplexer-demultiplexer potential meters, and phase meters. Data collecting was done by employing neighboring, while reconstruction was used the linear back-projection method from two different data frequencies, namely 10 kHz and 100 kHz. Phantom used in this experiment consists of distillated water and a carrot as an anomaly. Potential and phase data from the device is reconstructed to produce impedance, real, and imaginary images. Image analysis is performed by comparing the three images to the phantom. The experimental results show that the device is reliable.

1 January 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
KAKhusnul Ain
Khusnul Ain
HHHanik B. Hidayati
Hanik B. Hidayati
ONOlivia Aulia Nastiti
Olivia Aulia Nastiti
Stroke is a disease that has high mortality rate in Indonesia and worldwide. This disease is dangerous if not immediately treated because the brain circulatory disorder can cause a permanent disability or death. Diagnosis process of stroke disease can be assisted by an expert system using Naive Bayes Classifier and Certainty Factor. Decision making by Naive Bayes Classifier uses total probability value of all the diagnostic criteria on the existing database. Certainty Factor uses a weight value combination from measure of believe provided by expert. This expert system research aims to assist in the early diagnosis of a neurologist in diagnosing potential stroke patient from several diagnostic criteria as well as determine the accuracy of the expert system program created. The sample used in this study are the hospital medical records of 130 patients from Dr. Soetomo Hospital of Surabaya consists of 80 stroke patients data and 50 non-stroke patients data. Expert system program uses 12 category for diagnosis as an input and two statement outputs between stroke or non-stroke. Based on the analysis from the 25 testing data of 105 training data we obtained the accuracy of the method Naive Bayes classifier by 96% and of the method of Certainty Factor of 84%. Expert system program using Naive Bayes Classifier and Certainty Factor can be a device for stroke diagnosis.

1 January 2020 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
KAKhusnul Ain
Khusnul Ain
RWRarif Wibowo
Rarif Wibowo
SSSoegianto Soelistiono
Soegianto Soelistiono
LMLailatul Muniroh
Lailatul Muniroh
BABayu Ariwanto
Bayu Ariwanto
Body composition, through the information of total body water, extracellular fluid and intracellular fluid, fat-free mass, and fat mass from its impedance. BIS analysis can provide physiological statuses such as ischemia, pulmonary edema, skin cancer, and intramuscular tumors. BIS is expected to be used even more widely, both for hospital or home-based use, particularly because BIS handy, compact, inexpensive, and less power-consuming with adequately accurate real-time. In previous research, the BIS design was based on the magnitude-ratio and phase-difference detection using the AD8302 gain-phase detector method which resulted in an operating range between 20 kHz and 1 MHz. However, the impedance was obtained from the logarithmic ratio magnitude which caused the device to have limited accuracy at frequencies <20 kHz. Methods: In this research, we conduct design and development of a low-cost arduino-based electrical bioimpedance spectrometer. Results: The low-cost bioimpedance spectrometry was successfully developed using AD9850 as the programmable function generator, OPA2134 as the OpAm of voltage-controlled current source, AD620A as the instrument amplifier and AD536A as the alternating current to direct current converter which could work accurately from 0 Hz to 100 kHz. Conclusion: The multi-frequency bioimpedance device developed in this research has the capability to safely measure the impedance of the human body due to its relatively stable electric current, which is equal to (0.370 ± 0.003) mA with frequencies ranging from 5 to 200 kHz and has an accuracy of over 90% in the frequency range of 10 Hz to 100 kHz....

6 December 2024 in MethodsX
Verified
Journal Article
Open access
BABayu Ariwanto
Bayu Ariwanto
KAKhusnul Ain
Khusnul Ain
RRRiries Rulaningtyas
Riries Rulaningtyas
NUNuril Ukhrowiyah
Nuril Ukhrowiyah
RARohadatul Aisya
Rohadatul Aisya
AMAndi Besse Fidausiah Mansur
Andi Besse Fidausiah Mansur
Breast cancer is the most commonly diagnosed neoplasm and one of the most widespread cancers among women. The research advanced the Mf-EIT hardware through analogue discovery, component assessment, hardware integration, software creation, and data reconstruction utilizing Gauss-Newton and GREIT approaches. The breast cancer phantom consisted of a gelatin and sodium chloride solution. The position and number of anomalies in the reconstructed image correspond with the phantom. Anomalies in the reconstructed image are illustrated in red, indicating that they exhibit higher conductivity than their environment. The smallest percentage difference in conductivity between the reconstructed image of the cancer abnormality and the phantom is 0.18 %, recorded at a current of 0.35 mA and a frequency of 150 kHz. The smallest percentage difference in size between cancer abnormalities 1 and 2 in the reconstructed image and the phantom is 0.14 %, observed at a current of 0.22 mA and a frequency of 80 kHz. In brief, • This study proposes an innovative Electrical Impedance Tomography (EIT) • The designed and built the Mf-EIT hardware based on data reconstruction using Gauss-Newton and GREIT • The Electrical Impedance Tomography designed to detect the anomalies in the reconstructed image of Breast Cancer.

1 November 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
KAKhusnul Ain
Khusnul Ain
SSSoegianto Soelistiono
Soegianto Soelistiono
RWR. Arif Wibowo
R. Arif Wibowo
LMLailatul Muniroh
Lailatul Muniroh
TATri Anggono
Tri Anggono
WSW. Wulan Puspita Sari
W. Wulan Puspita Sari
Obesity is the beginning of the emergence of various chronic diseases such as stroke, heart failure, diabetes, and so on. Therefore, obesity becomes one of the indicators to know the health condition. Obesity can be known from Body Mass Index (BMI). BMI only considers weight and height, while obesity is related to fat composition, so this information is less valid. One method that can calculate body fat composition is Bioelectrical Impedance Analysis (BIA). BIA works by injecting a constant current into the body and measuring its voltage. This research designs and develops device to measure the body fat content with multi-frequency bio-impedance method. The study was conducted by generating a multi-frequency sine wave from AD9850 accompanied by a DC block so that an AC sine wave was generated. It would be converted into a constant current on VCCS. The electric current is injected into the body through two electrodes and the voltage was tapped by two another electrodes. The voltage are processed by instrument amplifier (AD620). AC signal from AD620 is converted to DC signal by AD536. Analog data is processed by ADC in the microcontroller so that the body impedance is obtained. The device was tested on 7 volunteers. The calculation of body fat was compared with standard OMRON HBF 214 device. In this research we got the linearity equation y = 0.999x + 0.161 with R2 = 0.997 as the result of correlation between the body fat from reference (x) and the measurement of body fat from the device was developed (y).