Viritpon Srimaneepong

Dr. Viritpon Srimaneepong

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2020 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
VSViritpon Srimaneepong
Viritpon Srimaneepong
WWWichaya Wisitrasameewon
Wichaya Wisitrasameewon
MHManoj Humagain
Manoj Humagain
PTPasutha Thunyakitpisal
Pasutha Thunyakitpisal
Despite the success rates of dental implants, peri-implantitis presents as the most common complication in implant dentistry. This review discusses various factors associated with peri-implantitis and various available treatments, highlighting their advantages and disadvantages. Relevant articles on peri-implantitis published in English were reviewed from August 2010 to April 2020 in MEDLINE/PubMed, Scopus, and ScienceDirect. The identified risk indicators of peri-implant diseases are plaque, smoking, history of periodontitis, surface roughness, residual cement, emergence angle >30 degrees, radiation therapy, keratinized tissue width, and function time of the implant, sex, and diabetes. Peri-implantitis treatments can be divided into nonsurgical (mechanical, antiseptic, and antibiotics), surface decontamination (chemical and laser), and surgical (air powder abrasive, resective, and regenerative). However, mechanical debridement alone may fail to eliminate the causative bacteria, and this treatment should be combined with other treatments (antiseptics and surgical treatment). Surface decontamination using chemical agents may be used as an adjuvant treatment; however, the definitive clinical benefit is yet not proven. Laser treatment may result in a short-term decrease in periodontal pocket depth, while air powder abrasive is effective in cleaning a previously contaminated implant surface. Surgical elimination of a pocket, bone recontouring and plaque control are also effective for treating peri-implantitis. The current evidence indicates that regenerative approaches to treat peri-implant defects are unpredictable.

1 November 2018 in Journal of Advanced Research
Verified
Journal Article
Open access
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
VSViritpon Srimaneepong
Viritpon Srimaneepong
JSJanak Sapkota
Janak Sapkota
Jiaqian QinJiaqian Qin
Jiaqian Qin
KSKrisana Siraleartmukul
Krisana Siraleartmukul
VSVilailuck Siriwongrungson
Vilailuck Siriwongrungson
The use of polymeric materials (PMs) and polymeric films (PMFs) has increased in medicine and dentistry. This increasing interest is attributed to not only the excellent surfaces of PMs and PMFs but also their desired mechanical and biological properties, low production cost, and ease in processing, allowing them to be tailored for a wide range of applications. Specifically, PMs and PMFs are used in dentistry for their antimicrobial, drug delivery properties; in preventive, restorative and regenerative therapies; and for corrosion and friction reduction. PMFs such as acrylic acid copolymers are used as a dental adhesive; polylactic acids are used for dental pulp and dentin regeneration, and bioactive polymers are used as advanced drug delivery systems. The objective of this article was to review the literatures on the latest advancements in the use of PMs and PMFs in medicine and dentistry. Published literature (1990-2017) on PMs and PMFs for use in medicine and dentistry was reviewed using MEDLINE/PubMed and ScienceDirect resources. Furthermore, this review also explores the diversity of latest PMs and PMFs that have been utilized in dental applications, and analyzes the benefits and limitations of PMs and PMFs. Most of the PMs and PMFs have shown to improve the biomechanical properties of dental materials, but in future, more clinical studies are needed to create better treatment guidelines for patients.

Verified
Journal Article
Open access
PDF file
VSViritpon Srimaneepong
Viritpon Srimaneepong
Artak HeboyanArtak Heboyan
Artak Heboyan
Muhammad Sohail ZafarMuhammad Sohail Zafar
Muhammad Sohail Zafar
Zohaib KhurshidZohaib Khurshid
Zohaib Khurshid
Anand MaryaAnand Marya
Anand Marya
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
Periodontal health plays an important role in the longevity of prosthodontic restorations. The issues of comparative assessment of prosthetic constructions are complicated and not fully understood. The aim of this article is to review and present the current knowledge regarding the various technical, clinical, and molecular aspects of different prosthetic biomaterials and highlight the interactions between periodontal health and prosthetic restorations. Articles on periodontal health and fixed dental prostheses were searched using the keywords “zirconium”, “CAD/CAM”, “dental ceramics”, “metal–ceramics”, “margin fit”, “crown”, “fixed dental prostheses”, “periodontium”, and “margin gap” in PubMed/Medline, Scopus, Google Scholar, and Science Direct. Further search criteria included being published in English, and between January 1981 and September 2021. Then, relevant articles were selected, included, and critically analyzed in this review. The margin of discrepancy results in the enhanced accumulation of dental biofilm, microleakage, hypersensitivity, margin discoloration, increased gingival crevicular fluid flow (GCF), recurrent caries, pulp infection and, lastly, periodontal lesion and bone loss, which can lead to the failure of prosthetic treatment. Before starting prosthetic treatment, the condition of the periodontal tissues should be assessed for their oral hygiene status, and gingival and periodontal conditions. Zirconium-based restorations made from computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide better results, in terms of marginal fit, inflammation reduction, maintenance, and the restoration of periodontal health and oral hygiene, compared to constructions made by conventional methods, and from other alloys. Compared to subgingival margins, supragingival margins offer better oral hygiene, which can be maintained and does not lead to secondary caries or periodontal disease.

10 January 2023 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
HSHans Erling Skallevold
Hans Erling Skallevold
VSViritpon Srimaneepong
Viritpon Srimaneepong
Anand MaryaAnand Marya
Anand Marya
PSPravin Shah
Pravin Shah
JSJanak Sapkota
Janak Sapkota
Shape memory polymers (SMPs) are emerging smart materials that have the ability to change to a shape and revert to their permanent shape on application of external stimulus. SMPs can be divided into four types based on their permanent shape, elasticity origin, and temporary shape fixing mechanism: chemically cross-linked glassy thermosets, chemically cross-linked semi-crystalline, physically cross-linked glassy copolymers, and physically cross-linked block copolymers. The broad overview of recent developments on SMPs for biomedical applications proves their wide applicability in the field of general medicine, drug delivery, regenerative medicine, dentistry, neuromedicine, cancer therapy, orthopedics, and corrosion protection. Herein, a comprehensive analysis of SMPs and their composites with focus on their types, mechanism, functionality and biomedical applications is presented. Relevant biomedical technologies based on SMPs and their future advancement towards biomedical applications are also discussed.

30 October 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SSSimone Shah
Simone Shah
DGDhanraj Ganapathy
Dhanraj Ganapathy
DVDeepak Nallaswamy Veeraiyan
Deepak Nallaswamy Veeraiyan
PAPadma Ariga
Padma Ariga
Artak HeboyanArtak Heboyan
Artak Heboyan
VSViritpon Srimaneepong
Viritpon Srimaneepong
Recently, polyetheretherketone (PEEK) has been introduced to the dental market as a high-performance and chemically inert biomaterial. This study aimed to compare the wear resistance, abrasiveness, color stability, and displacement resistance of zirconia and PEEK milled crowns. An ideal tooth preparation of a first maxillary molar was done and scanned by an intraoral scanner to make a digital model. Then, the prosthetic crown was digitally designed on the CAD software, and the STL file was milled in zirconia (CaroZiir S, Carol Zircolite Pvt. Ltd., Gujarat, India) and PEEK (BioHpp, Bredent GmbH, Senden, Germany) crowns using five-axis CNC milling machines. The wear resistance, color stability, and displacement resistance of the milled monolithic zirconia with unfilled PEEK crowns using a chewing simulator with thermocyclic aging (120,000 cycles) were compared. The antagonist wear, material wear, color stability, and displacement were evaluated and compared among the groups using the Wilcoxon–Mann–Whitney U-test. Zirconia was shown to be three times more abrasive than PEEK (p value < 0.05). Zirconia had twice the wear resistance of PEEK (p value < 0.05). Zirconia was more color stable than PEEK (p value < 0.05). PEEK had more displacement resistance than zirconia (p value < 0.05). PEEK offers minimal abrasion, better stress modulation through plastic deformation, and good color stability, which make it a promising alternative to zirconia crown.

Verified
Journal Article
Open access
PDF file
VSViritpon Srimaneepong
Viritpon Srimaneepong
HSHans Erling Skallevold
Hans Erling Skallevold
Zohaib KhurshidZohaib Khurshid
Zohaib Khurshid
Muhammad Sohail ZafarMuhammad Sohail Zafar
Muhammad Sohail Zafar
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
JSJanak Sapkota
Janak Sapkota
Graphene is a versatile compound with several outstanding properties, providing a combination of impressive surface area, high strength, thermal and electrical properties, with a wide array of functionalization possibilities. This review aims to present an introduction of graphene and presents a comprehensive up-to-date review of graphene as an antimicrobial and coating application in medicine and dentistry. Available articles on graphene for biomedical applications were reviewed from January 1957 to August 2020) using MEDLINE/PubMed, Web of Science, and ScienceDirect. The selected articles were included in this study. Extensive research on graphene in several fields exists. However, the available literature on graphene-based coatings in dentistry and medical implant technology is limited. Graphene exhibits high biocompatibility, corrosion prevention, antimicrobial properties to prevent the colonization of bacteria. Graphene coatings enhance adhesion of cells, osteogenic differentiation, and promote antibacterial activity to parts of titanium unaffected by the thermal treatment. Furthermore, the graphene layer can improve the surface properties of implants which can be used for biomedical applications. Hence, graphene and its derivatives may hold the key for the next revolution in dental and medical technology.