Studies seeking to determine the effects of gait retraining through biofeedback on peak tibial acceleration (PTA) assume that this biometric trait is a valid measure of impact loading that is reliable both within and between sessions. However, reliability and validity data were lacking for axial and resultant PTAs along the speed range of over-ground endurance running. A wearable system was developed to continuously measure 3D tibial acceleration and to detect PTAs in real-time. Thirteen rearfoot runners ran at 2.55, 3.20 and 5.10 m·s-1 over an instrumented runway in two sessions with re-attachment of the system. Intraclass correlation coefficients (ICCs) were used to determine within-session reliability. Repeatability was evaluated by paired T-tests and ICCs. Concerning validity, axial and resultant PTAs were correlated to the peak vertical impact loading rate (LR) of the ground reaction force. Additionally, speed should affect impact loading magnitude. Hence, magnitudes were compared across speeds by RM-ANOVA. Within a session, ICCs were over 0.90 and reasonable for clinical measurements. Between sessions, the magnitudes remained statistically similar with ICCs ranging from 0.50 to 0.59 for axial PTA and from 0.53 to 0.81 for resultant PTA. Peak accelerations of the lower leg segment correlated to LR with larger coefficients for axial PTA (r range: 0.64-0.84) than for the resultant PTA per speed condition. The magnitude of each impact measure increased with speed. These data suggest that PTAs registered per stand-alone system can be useful during level, over-ground, rearfoot running to evaluate impact loading in the time domain when force platforms are unavailable in studies with repeated measurements.
4 February 2020 in Frontiers in Bioengineering and Biotechnology
Ground reaction forces are often used by sport scientists and clinicians to analyze the mechanical risk-factors of running related injuries or athletic performance during a running analysis. An interesting ground reaction force-derived variable to track is the maximal vertical instantaneous loading rate (VILR). This impact characteristic is traditionally derived from a fixed force platform, but wearable inertial sensors nowadays might approximate its magnitude while running outside the lab. The time-discrete axial peak tibial acceleration (APTA) has been proposed as a good surrogate that can be measured using wearable accelerometers in the field. This paper explores the hypothesis that applying machine learning to time continuous data (generated from bilateral tri-axial shin mounted accelerometers) would result in a more accurate estimation of the VILR. Therefore, the purpose of this study was to evaluate the performance of accelerometer-based predictions of the VILR with various machine learning models trained on data of 93 rearfoot runners. A subject-dependent gradient boosted regression trees (XGB) model provided the most accurate estimates (mean absolute error: 5.39 ± 2.04 BW⋅s–1, mean absolute percentage error: 6.08%). A similar subject-independent model had a mean absolute error of 12.41 ± 7.90 BW⋅s–1 (mean absolute percentage error: 11.09%). All of our models had a stronger correlation with the VILR than the APTA (p < 0.01), indicating that multiple 3D acceleration features in a learning setting showed the highest accuracy in predicting the lab-based impact loading compared to APTA.
9 August 2018 in Journal of NeuroEngineering and Rehabilitation
Many gait impairments are characterized by asymmetry and result in reduced mobility. Exoskeletons could be useful for restoring gait symmetry by assisting only one leg. However, we still have limited understanding of the effects of unilateral exoskeleton assistance. Our aim was to compare the effects of unilateral and bilateral assistance using a within-subject study design. Eleven participants walked in different exoskeleton conditions. In the Unilateral conditions, only one leg was assisted. In Bilateral Matched Total Work, half of the assistance from the Unilateral conditions was applied to both legs such that the bilateral sum was equal to that of the Unilateral conditions. In Bilateral Matched Work Per Leg, the same assistance as in the Unilateral conditions was provided to both legs such that the bilateral sum was the double of that of the Unilateral conditions. In the Powered-Off condition, no assistance was provided. We measured metabolic energy consumption, exoskeleton mechanics and kinematics. On average, the Unilateral, Bilateral Matched Total Work and Bilateral Matched Work Per Leg conditions reduced the metabolic rate by 7, 11 and 15%, respectively, compared with the Powered-Off condition. A possible explanation for why the Unilateral conditions effectively reduced the metabolic rate could be that they caused only very little asymmetry in gait biomechanics, except at the ankle and in the horizontal center-of-mass velocity. We found the highest ratio of metabolic rate reduction versus positive work assistance with bilateral assistance and low work per leg (Bilateral Matched Total Work). Statistical analysis indicated that assistance symmetry and assistance per leg are more important than the bilateral summed assistance for reducing the metabolic rate of walking. These data bridge the gap between conclusions from studies with unilateral and bilateral exoskeletons and inform how unilateral assistance can be used to influence gait parameters, such as center-of-mass velocity.
4 January 2022 in Scandinavian Journal of Medicine & Science in Sports
Methods to reduce impact in distance runners have been proposed based on real-time auditory feedback of tibial acceleration. These methods were developed using treadmill running. In this study, we extend these methods to a more natural environment with a proof-of-concept. We selected ten runners with high tibial shock. They used a music-based biofeedback system with headphones in a running session on an athletic track. The feedback consisted of music superimposed with noise coupled to tibial shock. The music was automatically synchronized to the running cadence. The level of noise could be reduced by reducing the momentary level of tibial shock, thereby providing a more pleasant listening experience. The running speed was controlled between the condition without biofeedback and the condition of biofeedback. The results show that tibial shock decreased by 27% or 2.96 g without guided instructions on gait modification in the biofeedback condition. The reduction in tibial shock did not result in a clear increase in the running cadence. The results indicate that a wearable biofeedback system aids in shock reduction during over-ground running. This paves the way to evaluate and retrain runners in over-ground running programs that target running with less impact through instantaneous auditory feedback on tibial shock.