Daniel Alvarez

Dr. Daniel Alvarez

1. Biomedical Engineering Group (GIB), University of Valladolid, Paseo de Belén 15, 47011 Valladolid, Spain
+2
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2021 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
JLJeremy Levy
Jeremy Levy
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
ARAviv A. Rosenberg
Aviv A. Rosenberg
AAAlexandra Alexandrovich
Alexandra Alexandrovich
FCFélix del Campo
Félix del Campo
JBJoachim A. Behar
Joachim A. Behar
Pulse oximetry is routinely used to non-invasively monitor oxygen saturation levels. A low oxygen level in the blood means low oxygen in the tissues, which can ultimately lead to organ failure. Yet, contrary to heart rate variability measures, a field which has seen the development of stable standards and advanced toolboxes and software, no such standards and open tools exist for continuous oxygen saturation time series variability analysis. The primary objective of this research was to identify, implement and validate key digital oximetry biomarkers (OBMs) for the purpose of creating a standard and associated reference toolbox for continuous oximetry time series analysis. We review the sleep medicine literature to identify clinically relevant OBMs. We implement these biomarkers and demonstrate their clinical value within the context of obstructive sleep apnea (OSA) diagnosis on a total of n = 3806 individual polysomnography recordings totaling 26,686 h of continuous data. A total of 44 digital oximetry biomarkers were implemented. Reference ranges for each biomarker are provided for individuals with mild, moderate, and severe OSA and for non-OSA recordings. Linear regression analysis between biomarkers and the apnea hypopnea index (AHI) showed a high correlation, which reached $$\overline R ^2 = 0.82$$ R ¯ 2 = 0.82 . The resulting python OBM toolbox, denoted “pobm”, was contributed to the open software PhysioZoo (physiozoo.org). Studying the variability of the continuous oxygen saturation time series using pbom may provide information on the underlying physiological control systems and enhance our understanding of the manifestations and etiology of diseases, with emphasis on respiratory diseases.

16 October 2006 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MAM. Aboy
M. Aboy
Roberto HorneroRoberto Hornero
Roberto Hornero
Daniel AbasoloDaniel Abasolo
Daniel Abasolo
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
Lempel-Ziv complexity (LZ) and derived LZ algorithms have been extensively used to solve information theoretic problems such as coding and lossless data compression. In recent years, LZ has been widely used in biomedical applications to estimate the complexity of discrete-time signals. Despite its popularity as a complexity measure for biosignal analysis, the question of LZ interpretability and its relationship to other signal parameters and to other metrics has not been previously addressed. We have carried out an investigation aimed at gaining a better understanding of the LZ complexity itself, especially regarding its interpretability as a biomedical signal analysis technique. Our results indicate that LZ is particularly useful as a scalar metric to estimate the bandwidth of random processes and the harmonic variability in quasi-periodic signals

13 January 2006 in Physiological Measurement
Verified
Journal Article
Closed access
Daniel AbasoloDaniel Abasolo
Daniel Abasolo
Roberto HorneroRoberto Hornero
Roberto Hornero
PEP Espino
P Espino
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
JPJesus Poza
Jesus Poza
Alzheimer's disease (AD) is the most common neurodegenerative disorder. Although a definite diagnosis is only possible by necropsy, a differential diagnosis with other types of dementia and with major depression should be attempted. The aim of this study was to analyse the electroencephalogram (EEG) background activity of AD patients to test the hypothesis that the regularity of the AD patients' EEG is higher than that of age-matched controls. We recorded the EEG from 19 scalp electrodes in 11 AD patients and 11 age-matched controls. Two different methods were used to estimate the regularity of the EEG background activity: spectral entropy (SpecEn) and sample entropy (SampEn). We did not find significant differences between AD patients and control subjects' EEGs with SpecEn. On the other hand, AD patients had significantly lower SampEn values than control subjects (p < 0.01) at electrodes P3, P4, O1 and O2. Our results show an increase of EEG regularity in AD patients. These findings suggest that nonlinear analysis of the EEG with SampEn could yield essential information and may contribute to increasing the insight into brain dysfunction in AD in ways which are not possible with more classical and conventional statistical methods.

8 July 2010 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
Roberto HorneroRoberto Hornero
Roberto Hornero
JMJ. Victor Marcos
J. Victor Marcos
FCFélix del Campo
Félix del Campo
This study focuses on the analysis of blood oxygen saturation (SaO2) from nocturnal pulse oximetry (NPO) to help in the diagnosis of the obstructive sleep apnea (OSA) syndrome. A population of 148 patients suspected of suffering from OSA syndrome was studied. A wide set of 16 features was used to characterize changes in the SaO2 profile during the night. Our feature set included common statistics in the time and frequency domains, conventional spectral characteristics from the power spectral density (PSD) function, and nonlinear features. We performed feature selection by means of a step-forward logistic regression (LR) approach with leave-one-out cross-validation. Second- and fourth-order statistical moments in the time domain (M2t and M4t), the relative power in the 0.014-0.033 Hz frequency band (PR), and the Lempel-Ziv complexity (LZC) were automatically selected. 92.0% sensitivity, 85.4% specificity, and 89.7% accuracy were obtained. The optimum feature set significantly improved the diagnostic ability of each feature individually. Furthermore, our results outperformed classic oximetric indexes commonly used by physicians. We conclude that simultaneous analysis in the time and frequency domains by means of statistical moments, spectral and nonlinear features could provide complementary information from NPO to improve OSA diagnosis.

12 August 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
JLJeremy Levy
Jeremy Levy
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
FCFélix del Campo
Félix del Campo
JBJoachim A. Behar
Joachim A. Behar
Obstructive sleep apnea (OSA) is a serious medical condition with a high prevalence, although diagnosis remains a challenge. Existing home sleep tests may provide acceptable diagnosis performance but have shown several limitations. In this retrospective study, we used 12,923 polysomnography recordings from six independent databases to develop and evaluate a deep learning model, called OxiNet, for the estimation of the apnea-hypopnea index from the oximetry signal. We evaluated OxiNet performance across ethnicity, age, sex, and comorbidity. OxiNet missed 0.2% of all test set moderate-to-severe OSA patients against 21% for the best benchmark.

15 December 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
Roberto HorneroRoberto Hornero
Roberto Hornero
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
MPMona F. Philby
Mona F. Philby
MAMaría Luz Alonso-Álvarez
María Luz Alonso-Álvarez
David GozalDavid Gozal
David Gozal
Rationale: The vast majority of children around the world undergoing adenotonsillectomy for obstructive sleep apnea–hypopnea syndrome (OSA) are not objectively diagnosed by nocturnal polysomnography because of access availability and cost issues. Automated analysis of nocturnal oximetry (nSpO2), which is readily and globally available, could potentially provide a reliable and convenient diagnostic approach for pediatric OSA. Methods: Deidentified nSpO2 recordings from a total of 4,191 children originating from 13 pediatric sleep laboratories around the world were prospectively evaluated after developing and validating an automated neural network algorithm using an initial set of single-channel nSpO2 recordings from 589 patients referred for suspected OSA. Measurements and Main Results: The automatically estimated apnea–hypopnea index (AHI) showed high agreement with AHI from conventional polysomnography (intraclass correlation coefficient, 0.785) when tested in 3,602 additional subjects. Further assessment on the widely used AHI cutoff points of 1, 5, and 10 events/h revealed an incremental diagnostic ability (75.2, 81.7, and 90.2% accuracy; 0.788, 0.854, and 0.913 area under the receiver operating characteristic curve, respectively). Conclusions: Neural network–based automated analyses of nSpO2 recordings provide accurate identification of OSA severity among habitually snoring children with a high pretest probability of OSA. Thus, nocturnal oximetry may enable a simple and effective diagnostic alternative to nocturnal polysomnography, leading to more timely interventions and potentially improved outcomes.