Gencho Popov

Prof. Gencho Popov


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
GPGencho Popov
Gencho Popov
KKKliment Klimentov
Kliment Klimentov
Boris KostovBoris Kostov
Boris Kostov
RDReneta Dimitrova
Reneta Dimitrova
This work represents a method for investigating the energy efficiency of fan systems used to transport fluids. Applying the methods of dimensional analysis (DA) enables establishing five dimensionless complexes ( π criteria), including some basic parameters having impacts on the consumed energy used for the transportation of a unit quantity of air. The proposed criterion π 1 includes the specific energy consumption e v (specific fan power SFP), and is used for the quantitative evaluation of the energy effectiveness of the fluid transportation. This criterion also includes the main geometric size of the pipe system (network) and the gas properties. The criterion π 3 indicates the impact of the applied method of flow rate regulation on the effective energy use of fan systems. This criterion includes parameters characterizing the selected method of flow rate regulation: speed ( n ) for using the frequency method and the referred length ( L T P ) of the pipe system for using the throttle method. The established (proposed) dimensionless parameters are used to study a concrete fan system. The obtained results concerning the evaluation of the impact of the two most used methods of flow rate regulation (frequency and throttle), as well as the density variation as a result of the temperature change, on the effective energy use are graphically presented: π 1 = f ( π 3 ) .

1 September 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
GPGencho Popov
Gencho Popov
KKK V Klimentov
K V Klimentov
BKB Z Kostov
B Z Kostov
The ensuring of the required parameters of the air, used in air-conditioning systems, is directly related to the change of the flow rate of each fan that is installed in these systems. This change can be achieved by using different methods of flow rate regulation. However, it is well-known that the selected method determines the energy efficiency of the given fan system. This work represents a comparative theoretical analysis, concerning the energy efficiency of three different methods of regulating a fan’s flow rate: by throttling, by using inlet guide vanes and by changing the voltage frequency - the motor’s speed of rotation has been changed with the help of a variable frequency drive (VFD). For the aims of this research, the change of the coefficient of efficiency for some of the key system elements – fan, motor and VFD, at different work regimes, have also been indicated. To fulfil the objectives of this research a given number of fans, having different specific speeds of rotations: nq = 3.31; 7.11 and 8.82 min−1, have been selected. As a criteria of effectiveness, concerning the different methods of flow rate regulation, the specific fan power PSFP - the invested energy in transporting a unit volume of fluid (gas), has been used: P S F P = p η t o t [ k W m 3 / s ] , where p is the total pressure of the fan; ηtot is the overall efficiency of the fan. As a result of this theoretical investigation some graphics representing the change of the specific energy consumption, when the three different methods of flow rate regulation are used and indicating the fan’s initial work regime and its specific speed of rotation, have been given.

25 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
GPGencho Popov
Gencho Popov
Stanisław LegutkoStanisław Legutko
Stanisław Legutko
KKKliment Klimentov
Kliment Klimentov
Boris KostovBoris Kostov
Boris Kostov
This paper presents a method for evaluating the energy efficiency of pump systems used to transport fluids .It is mainly scientifically applied and engineering-applied in nature and aims to propose a new approach (method) to researchers in their study of the energy efficiency of such systems. By applying the well-known scientific method of Dimensional Analysis (Buckingham π-theorem), dimensionless complexes (π-criterions and their relevant equations, which are original (innovative) and are offered for the first time in the scientific literature), used in accomplishing an energy assessment and analysis of such systems, are obtained. The criterion ∏1 = ev/ρgD represents specific energy consumption in kWh/m3 for a given pipe system with an exemplary diameter D. The criterion ∏2 = Q/[n(Hp − Hst)D2] represents a generalized parameter which is characterized by the selected method of flow rate (Q) regulation for a pump system with given static head Hst—by changing the speed of rotation (VFD, Variable Frequency Drive), by throttling, leading to an increase of the system hydraulic losses hv = (HpHst) or by diverting a part of the flow, known as “by-pass”, where the pump operates with the required system head Hp, but ensures higher flow rates, i.e., Qp > Qs. The flow rate criterion ∏3 = Q/(νD) characterizes the flow rate for a pipe system with an exemplary diameter D, used to transport a liquid with known viscosity ν. An example for applying these dimensionless complexes in accomplishing a quantitative evaluation of the energy efficiency of a given pump system is presented. A method for determining the main parameters forming these criterions, used to describe the different methods of flow rate regulation, has been developed. To demonstrate the application of this method, newly proposed by the authors, including obtaining the relevant criteria equations of the type ∏1 = f(∏2, ∏3), a certain pump system was used. This original approach for studying pump systems used to transport fluids can be used both to accomplish an energy analysis of such systems as well as to solve for optimization or other engineering problems.

24 July 2020
Verified
Conference Paper
Open access
PDF file
GPGencho Popov
Gencho Popov
KKKliment Klimenntov
Kliment Klimenntov
BKBoris Kostov
Boris Kostov
This work intend an original methodology, newly established by the authors, to design typical pipe systems by using hydraulic criteria equations, excluding the determination of the relevant Darcy factor. Therefore, it can be eliminated the necessity for searching iterative solutions of such problems. The established equations are easy to use, in terms of mathematical processing, which guarantees their proper application in solving engineering problems. It is considered for the proposed physical relations (equations) concerning the determination of the pipe system resistance characteristics to be highly useful in engineering practice, as for example: in determining a hydraulic machine work regime, used in a system transporting fluids, as well as in performing a synthesis and analysis of such systems or in accomplishing an energy analysis of pipe systems. A comparative analysis between the results found after applying the classical methods of calculations and by using a licensed specialized software product indicates that a highly sufficient (for engineering calculations) overlapping is achieved.

18 November 2020 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
GPGencho Popov
Gencho Popov
KKKliment Klimentov
Kliment Klimentov
BKBoris Kostov
Boris Kostov
RDReneta Dimitrova
Reneta Dimitrova
This work represents results concerning different methods, used to determine the minor loss coefficient of a cone diffuser, installed at the system’s outlet. These results are compared with experimental data and numerical results, obtained after using ANSYS CFX and the data base of Pipe Flow Expert. For determining the minor loss coefficient of a cone diffuser, being installed at the system outlet and having a straight pipe section in front of it, some models in ANSYS CFX are established. These models are validated by using previously published experimental data. An empirical equation, based on the results found, enabling the accomplishment of analytical studies concerning the energy efficiency of fan systems, using an outlet diffuser, has been established.

26 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jan GóreckiJan Górecki
Jan Górecki
KKKliment Klimentov
Kliment Klimentov
GPGencho Popov
Gencho Popov
Boris KostovBoris Kostov
Boris Kostov
SISalaf Ruzhdi Ibrahim
Salaf Ruzhdi Ibrahim
The head, efficiency, and cavitation characteristics of centrifugal pumps are highly dependent on the velocity field in front of the impeller inlet. In multistage pumps, the velocity field in front of the second and each subsequent stage is determined by the shape (design) of the diffuser return guide vanes. This current work presents the results obtained by performing a numerical study using ANSYS CFX 14.0 to determine the impact of the shape (design) of diffuser return guide vanes on the head and coefficient of efficiency of one stage of a multistage centrifugal pump. Three RGVs with different Outlet angles are studied: α6—original RGV with α6=90 deg, RGV1 with α6=110 deg and RGV2 with α6=128 deg. The results obtained after performing CFD modeling indicate that with one of the studied RGVs, the pump stage head increases by nearly 20%, while the hydraulic coefficient of efficiency remains almost constant. Applying entropy production theory is used to determine the impact of the various components of entropy production on the total head loss in the studied pump stage. The impact of the Outlet angle of the RGV on the velocity field of the flow in front of the next impeller (stage) as well as the RGV head is also analyzed. The numerical results of the original RGV are compared with the experimental data obtained from large-scale studies of pumps performed at the Laboratory of Hydraulic Machines of the University “Angel Kanchev” of Ruse, Bulgaria. When using the modified RGVs, the head curve of the original pump can be obtained by operating at a lower speed or with a smaller impeller diameter. This may lead to an overall increase in the energy efficiency of the machine, which could be explored as a future task.