Kliment Klimentov

Prof. Kliment Klimentov


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
GPGencho Popov
Gencho Popov
KKKliment Klimentov
Kliment Klimentov
Boris KostovBoris Kostov
Boris Kostov
RDReneta Dimitrova
Reneta Dimitrova
This work represents a method for investigating the energy efficiency of fan systems used to transport fluids. Applying the methods of dimensional analysis (DA) enables establishing five dimensionless complexes ( π criteria), including some basic parameters having impacts on the consumed energy used for the transportation of a unit quantity of air. The proposed criterion π 1 includes the specific energy consumption e v (specific fan power SFP), and is used for the quantitative evaluation of the energy effectiveness of the fluid transportation. This criterion also includes the main geometric size of the pipe system (network) and the gas properties. The criterion π 3 indicates the impact of the applied method of flow rate regulation on the effective energy use of fan systems. This criterion includes parameters characterizing the selected method of flow rate regulation: speed ( n ) for using the frequency method and the referred length ( L T P ) of the pipe system for using the throttle method. The established (proposed) dimensionless parameters are used to study a concrete fan system. The obtained results concerning the evaluation of the impact of the two most used methods of flow rate regulation (frequency and throttle), as well as the density variation as a result of the temperature change, on the effective energy use are graphically presented: π 1 = f ( π 3 ) .

25 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
GPGencho Popov
Gencho Popov
Stanisław LegutkoStanisław Legutko
Stanisław Legutko
KKKliment Klimentov
Kliment Klimentov
Boris KostovBoris Kostov
Boris Kostov
This paper presents a method for evaluating the energy efficiency of pump systems used to transport fluids .It is mainly scientifically applied and engineering-applied in nature and aims to propose a new approach (method) to researchers in their study of the energy efficiency of such systems. By applying the well-known scientific method of Dimensional Analysis (Buckingham π-theorem), dimensionless complexes (π-criterions and their relevant equations, which are original (innovative) and are offered for the first time in the scientific literature), used in accomplishing an energy assessment and analysis of such systems, are obtained. The criterion ∏1 = ev/ρgD represents specific energy consumption in kWh/m3 for a given pipe system with an exemplary diameter D. The criterion ∏2 = Q/[n(Hp − Hst)D2] represents a generalized parameter which is characterized by the selected method of flow rate (Q) regulation for a pump system with given static head Hst—by changing the speed of rotation (VFD, Variable Frequency Drive), by throttling, leading to an increase of the system hydraulic losses hv = (HpHst) or by diverting a part of the flow, known as “by-pass”, where the pump operates with the required system head Hp, but ensures higher flow rates, i.e., Qp > Qs. The flow rate criterion ∏3 = Q/(νD) characterizes the flow rate for a pipe system with an exemplary diameter D, used to transport a liquid with known viscosity ν. An example for applying these dimensionless complexes in accomplishing a quantitative evaluation of the energy efficiency of a given pump system is presented. A method for determining the main parameters forming these criterions, used to describe the different methods of flow rate regulation, has been developed. To demonstrate the application of this method, newly proposed by the authors, including obtaining the relevant criteria equations of the type ∏1 = f(∏2, ∏3), a certain pump system was used. This original approach for studying pump systems used to transport fluids can be used both to accomplish an energy analysis of such systems as well as to solve for optimization or other engineering problems.

26 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jan GóreckiJan Górecki
Jan Górecki
KKKliment Klimentov
Kliment Klimentov
GPGencho Popov
Gencho Popov
Boris KostovBoris Kostov
Boris Kostov
SISalaf Ruzhdi Ibrahim
Salaf Ruzhdi Ibrahim
The head, efficiency, and cavitation characteristics of centrifugal pumps are highly dependent on the velocity field in front of the impeller inlet. In multistage pumps, the velocity field in front of the second and each subsequent stage is determined by the shape (design) of the diffuser return guide vanes. This current work presents the results obtained by performing a numerical study using ANSYS CFX 14.0 to determine the impact of the shape (design) of diffuser return guide vanes on the head and coefficient of efficiency of one stage of a multistage centrifugal pump. Three RGVs with different Outlet angles are studied: α6—original RGV with α6=90 deg, RGV1 with α6=110 deg and RGV2 with α6=128 deg. The results obtained after performing CFD modeling indicate that with one of the studied RGVs, the pump stage head increases by nearly 20%, while the hydraulic coefficient of efficiency remains almost constant. Applying entropy production theory is used to determine the impact of the various components of entropy production on the total head loss in the studied pump stage. The impact of the Outlet angle of the RGV on the velocity field of the flow in front of the next impeller (stage) as well as the RGV head is also analyzed. The numerical results of the original RGV are compared with the experimental data obtained from large-scale studies of pumps performed at the Laboratory of Hydraulic Machines of the University “Angel Kanchev” of Ruse, Bulgaria. When using the modified RGVs, the head curve of the original pump can be obtained by operating at a lower speed or with a smaller impeller diameter. This may lead to an overall increase in the energy efficiency of the machine, which could be explored as a future task.

1 January 2023 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
KKKliment Klimentov
Kliment Klimentov
DNDesislava Nikolova
Desislava Nikolova
GPGencho Popov
Gencho Popov
BKBoris Kostov
Boris Kostov
It is well-known that one of the reasons for reducing the head of a centrifugal pump, when trimming its impeller, is the reduction of the slip factor. There are various methods used to determine it, but there is lack of information on whether they are applicable in case that a pump with a trimmed impeller operates. In the present work, a comparative experimental study concerning the applicability of some of the methods used to determine the slip factor, on two centrifugal pumps with different specific speed of rotation, is performed. Based on the experimental data, CFD models of the impellers of the two pumps have been validated and a numerical simulation study concerning the change of the slip factor during trimming, has also been performed. The impact of the rate of impeller trimming on the the slip factor variation has also been established. Based on the results found, concerning the performed numerical study, equations describing the relationship between the slip factor and the rate of trimming of the studied pumps are obtained.

23 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
KKKliment Klimentov
Kliment Klimentov
GPGencho Popov
Gencho Popov
Boris KostovBoris Kostov
Boris Kostov
SISalaf Ruzhdi Ibrahim
Salaf Ruzhdi Ibrahim
The study evaluates the influence of expeller vanes on the hydrodynamics of a centrifugal pump and on the generated axial and radial forces. Four geometric impeller variants with different con-figurations and numbers of expeller vanes were analyzed. The results show that the addition of expeller vanes significantly modifies the unsteady hydrodynamic structures and leads to substantial changes in force amplitudes. Geometry G1 exhibits the most unfavorable radial load behavior, whereas geometry G3 provides the most balanced hydraulic and mechanical performance. Modifi-cation G4 improves the radial force but increases axial force fluctuations due to the larger number of rear expeller vanes. In conclusion, configuration G3 is identified as the optimal design, offering the best compromise between hydraulic efficiency, load stability, and mechanical reliability.