Antonios Stylogiannis

Mr. Antonios Stylogiannis

Helmholtz-Zentrum Muenchen, Institute of Biological and Medical Imaging
+1

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ASAntonios Stylogiannis
Antonios Stylogiannis
Nikos KousiasNikos Kousias
Nikos Kousias
AKAnastasios Kontses
Anastasios Kontses
LNLeonidas Ntziachristos
Leonidas Ntziachristos
VNVasilis Ntziachristos
Vasilis Ntziachristos
Attention to Black Carbon (BC) has been rising due to its effects on human health as well its contribution to climate change. Measurements of BC are challenging, as currently used devices are either expensive or impractical for continuous monitoring. Here, we propose an optoacoustic sensor to address this problem. The sensor utilizes a novel ellipsoidal design for refocusing the optoacoustic signal with minimal acoustic energy losses. To reduce the cost of the system, without sacrificing accuracy, an overdriven laser diode and a Quartz Tuning Fork are used as the light source and the sound detector, respectively. The prototype was able to detect BC particles and to accurately monitor changes in concentration in real time and with very good agreement with a reference instrument. The response of the sensor was linearly dependent on the BC particles concentration with a normalized noise equivalent absorption coefficient (NNEA) for soot equal to 7.39 × 10−9 W cm−1 Hz−1/2. Finally, the prototype was able to perform NO2 measurements, demonstrating its ability to accurately monitor both particulate and gaseous pollutants. The proposed sensor has the potential to offer a significant economic impact for BC environmental measurements and source appointment technologies.

30 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Chen YangChen Yang
Chen Yang
XJXiaohua Jian
Xiaohua Jian
XZXinle Zhu
Xinle Zhu
JLJiabing Lv
Jiabing Lv
YJYang Jiao
Yang Jiao
YCYaoyao Cui
Yaoyao Cui
Photoacoustic (PA) imaging is a hybrid imaging technique that can provide both structural and functional information of biological tissues. Due to limited permissible laser energy deposited on tissues, highly sensitive PA imaging is required. Here, we developed a 20 MHz lead zirconium titanate (PZT) transducer (1.5 mm × 3 mm) with front-end amplifier circuits for local signal processing to achieve sensitivity enhanced PA imaging. The electrical and acoustic performance was characterized. Experiments on phantoms and chicken breast tissue were conducted to validate the imaging performance. The fabricated prototype shows a bandwidth of 63% and achieves a noise equivalent pressure (NEP) of 0.24 mPa/√Hz and a receiving sensitivity of 62.1 μV/Pa at 20 MHz without degradation of the bandwidth. PA imaging of wire phantoms demonstrates that the prototype is capable of improving the detection sensitivity by 10 dB compared with the traditional transducer without integrated amplifier. In addition, in vitro experiments on chicken breast tissue show that structures could be imaged with enhanced contrast using the prototype and the imaging depth range was improved by 1 mm. These results demonstrate that the transducer with an integrated front-end amplifier enables highly sensitive PA imaging with improved penetration depth. The proposed method holds the potential for visualization of deep tissue structures and enhanced detection of weak physiological changes.