Paper presents a mathematical model of the radial active magnetic bearing, which is indented for the simulation of the magnetic bearing dynamic response. The circuit model of the bearing is based on differential equations. The circuit model has incorporated results of magnetic field analysis, which led to the creation of the field–circuit model. Presented model of the magnetic bearing takes into account the necessary control system. The experimental results are presented to validate the proposed model.
1 July 2019 in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
Purpose: The purpose of this paper is to create a reliable nonlinear magnetic equivalent circuit (NMEC) of the hybrid magnetic bearing (HMB). Commonly used magnetic equivalent circuits of HMB omit a saturation effect of the magnetic material as well as the leakage and fringing flux. It results in imprecise modelling of the magnetic field distribution. On the other hand, only 3D finite element analysis (FEA) can be used to precisely simulate the magnetic field in this type of the magnetic bearing. The proposed NMEC incorporates the saturation effect of the magnetic material, as well as the leakage and fringing flux. Design/methodology/approach: The magnetic equivalent circuit of presented HMB is proposed to obtain a reliable model that ensures short calculation time. Developed NMEC incorporates the phenomena as the saturation effect, as well as the leakage and fringing flux. The reluctance of the air gap that includes the fringing flux was calculated using 3D FEA. Kirchhoffs’ laws were used to create a set of nonlinear equations that were iteratively solved by Broyden’s method. Findings: Incorporating into NMEC of the HMB a saturation effect of the magnetic material, as well as the leakage and fringing flux, resulted in the accurate model that was in good agreement with 3 D finite element model and the real object. The developed NMEC offers the calculation time in the range of miliseconds, therefore can be successfully used in the engineering design instead of the FEM. Originality/value: Presented NMEC can be considered as a fundamental model that can be successfully used for accurate and fast simulation of the HMB. Proposed NMEC includes considerable factors that decide about the model accuracy such as the saturation effect of the ferromagnetic material and the leakage and fringing flux. The developed NMEC can be used in the optimization procedures and for simulations of dynamic responses.
A comparison of two developed simulation models for a hybrid magnetic bearing (HMB) transient states is presented. This applies to analyses using the flux-circuit directly coupled magnetic equivalent circuit and field-circuit indirectly coupled finite element analysis. The required control system was implemented for both models. The results obtained from the simulations were compared with those obtained from measurement tests.
The paper presents a simulation model of the hybrid magnetic bearing dedicated to simulations of transient state. The proposed field-circuit model is composed of two components. The first part constitutes a set of ordinary differential equations that describes electrical circuits and mechanics. The second part of the simulation model consists of parameters such as magnetic forces, dynamic inductances and velocity-induced voltages obtained from the 3D finite element analysis. The MATLAB/Simulnik softwarewas used to implement the simulation model with the required control system. The proposed field-circuit model was validated by comparison of time responses with the prototype of the hybrid magnetic bearing.
This article proposes a method to modify the construction of a medium voltage (MV) heat shrinkable cable termination in cases of atypical damage to the shields of cross-linked polyethylene (XLPE) insulated cables. The proposed solutions include a modified method of assembling electric field control coating. An attempt was made to check the effect of such damage to the shields of MV cables with XLPE insulation on the level of occurrence of partial discharges within the cable termination. The investigations included testing the XRUHAKXS 1 × 240/25 cable type using the electric method (ME) and high frequency (HF) method with sinusoidal AC test voltage. As a result of the measurements, the values of total charges in the period and phase-resolved partial discharge (PRPD) patterns were obtained. The presented experimental results show the influence of the damage of the semiconducting coating surface on the occurrence of a defect in the cable termination without a modified method of control mantissa pinning. We suggest new methods of assembling MV cable accessories in the case of the presented coating damage in MV cable insulation.
The paper presents simulation and experimental verification of the hybrid magnetic bearing (HMB) performance characteristics. It has been demonstrated that the additional errors from the eddy current sensors have a significant impact on the control signals. An improved mathematical model combines a nonlinear magnetic equivalent circuit of the HMB with the ordinary differential equations of its transients. These equations describe the rotor motion and the electric circuit of the system, as well as the control system required for stable levitation of the rotor. Certain harmonics have been observed in the displacement signals of frequencies equal to the multiples of the cylinder rotations. The calculation model has, therefore, been improved, taking into account the interference of the harmonics. Simulation results were validated by comparing the time responses of the transients obtained from the numerical calculations with those measured on a real object; a satisfactory agreement between the results has been achieved.