This paper presents a -Coriolis mass flow sensor with resistive readout. Instead of measuring a net displacement such as in a capacitive readout, a resistive readout detects the deformation of the suspended micro-fluidic channel. It allows for actuation at much higher amplitudes than for a capacitive readout, resulting in correspondingly larger Coriolis forces in response to fluid flow. A resistive readout can be operated in two actuation vibrational modes. A capacitive readout can only be operated in one of these two modes, which is more sensitive to external disturbances. Three types of devices have been realized. We present measurement results for all three devices. One device clearly outperforms the other two, with a flow sensitivity of 2.22 °/(g·h−1) and a zero-flow stability of 0.02 g·h−1 over 30 min. Optimization of the metal strain gauges and/or implementation of poly-Silicon strain gauges could further improve performance.
We report on a novel resistive pressure sensor that is completely integrated with a Coriolis mass flow sensor on one chip, without the need for extra fabrication steps or different materials. Two pressure sensors are placed in-line with the Coriolis sensor without requiring any changes to the fluid path. This enables the measurement over the pressure drop of the Coriolis mass flow sensor and ΔP flow sensing. By combining this pressure drop with the output signal of the Coriolis mass flow sensor, real-time viscosity characterization is also possible. Since the pressure sensor consists of a Wheatstone bridge, no complex interfacing electronics are needed. The first characterization of the sensor shows a linear sensitivity of 4 μV bar -1 for a pressure range from 0 bar to 1 bar.
This paper reports on a fluid viscosity sensor consisting of pressure sensors fully integrated with a Coriolis mass flow sensor. The sensor is capable of measuring viscosities of both liquids and gases through a mathematical model. For liquids, this model is simply the Hagen-Poiseuille equation. For gases, a more elaborate model is derived, taking into account compressibility and additional pressure losses due to channel geometry. Viscosities of (mixtures of) water and isopropanol were measured and correspond well with values found in literature. Viscosities of nitrogen and argon were measured with accuracies of -0-12%, depending on input pressure and mass flow rate. Improvement of the mathematical model could lead to higher accuracy and less dependence on mass flow or pressure.
In this paper we present a $\mu $ -Coriolis mass flow sensor with differential capacitive readout, which can reduce the effect of common mode vibrations caused by external disturbances. The device consists of two silicon nitride micro-channel loops mechanically connected through two membranes. The sensor is actuated using Lorentz forces, inducing rotation of the sensor's micro-channels. Coriolis forces of opposite sign are subsequently generated in the two channel loops. Thus, any common mode vibration can be distinguished from vibration induced by mass flow through the channels. Capacitive readout structures surround the sensor to detect these vibrations. A piezo-electric resonator is placed in close proximity to the sensor to generate artificial external disturbance. Flow measurements are executed to compare the differential readout method to a single ended readout with and without external disturbances. The flow sensitivity is unaffected. However, the mean deviation of the output signal is 60-70% lower when using the differential readout compared to single ended readout when external disturbances are induced. The effect of external disturbances on the zero flow stability is reduced by approximately 64% by using the differential readout. Full elimination of the effect is not possible due to non-linearity of the readout capacitors. Reducing non-linearity of the readout could further improve performance, e.g. by implementing (piezo-resistive) strain gauges on top of the micro-channel.