Spatial and temporal variations of the hemodynamic features occur under pulsatile conditions in complex vessel geometry. Wall shear stress affected by the disturbed flow can result in endothelial cell dysfunction, which leads to atherogenesis and thrombosis. Therefore, detailed understanding of the hemodynamic characteristics in a curved stenosed channel is highly important when examining the pathological effects of hemodynamic phenomena on the progression of atherosclerosis. The present study measures the velocity fields of pulsatile flows with three different Reynolds numbers in 3D curved vessel models with stenosis using time-resolved particle image velocimetry (PIV). Three different models were cast in PDMS polymer using models made by a 3D printer with different bend angles of 0°, 10°, and 20° between the longitudinal axes at the upstream and downstream of the stenosis. To investigate the 3D flow structures, a stack of 2D velocity fields was obtained by adjusting the position of the laser sheet along the Z-direction. The structures of flow fields in the stenosed models were analyzed using the distribution of the shearing strain as well as the skewness and full width at half maximum of the velocity profile. To support experiment results, distributions of pressure and 3D vortex in the curved stenosed channels were estimated by conducting the numerical simulation. These results indicate that the curvature of the tube considerably influences the skewness of the flow, and the shear stress is intensified near the outer curvature wall due to centrifugal force. The results would be helpful in understanding the effects of geometrical factors on plaque rupture and severe cardiovascular diseases.
Three-dimensional (3D) curved wall jets are a significant topic in various applications related to local heat and mass transfer. This study investigates the effects of the impinging angle and Reynolds number with a fixed distance from the nozzle to the surface of a cylinder. The particle image velocimetry (PIV) method was used to measure the mean streamwise velocity profiles, which were normalized by the maximum velocity along the centerline of the impinging jet onto the cylinder. After the impingement of the circular jet, a 3D curved wall jet develops on the cylinder surface due to the Coanda effect. At a given Reynolds number, the initial momentum of the wall jet increases, and flow separation occurs further downstream than in normal impingement as the impinging angle increases. At a given impinging angle, flow separation is delayed with increasing Reynolds number. A self-preserving wall jet profile was not attained in the 3D curved wall jet. The turbulence intensity and the Reynolds shear stress were obtained to analyze the turbulence characteristics. The radial turbulence intensity showed similar tendencies to a two-dimensional (2D) curved wall jet, but the streamwise turbulence intensity was dissimilar. The Reynolds shear stress decreases downstream of the cylinder wall due to the decreased velocity and centrifugal force.
In studying blood flow in the vessels, the characteristics of non-Newtonian fluid are important, considering the role of viscosity in rheology. Stenosis, which is an abnormal narrowing of the vessel, has an influence on flow behavior. Therefore, analysis of blood flow in stenosed vessels is essential. However, most of them exist as simulation outcomes. In this study, non-Newtonian fluid was observed in stenosed microchannels under the pulsatile flow condition. A polydimethylsiloxane channel with 60% stenosis was fabricated by combining an optic fiber and a petri dish, resembling a mold. Three types of samples were prepared by changing the concentrations of xanthan gum, which induces a shear thinning effect (phosphate buffered saline (PBS) solution as the Newtonian fluid and two non-Newtonian fluids mimicking normal blood and highly viscous blood analog). The viscosity of the samples was measured using a Y-shaped microfluidic viscometer. Thereafter, velocity profiles were analyzed under the pulsatile flow condition using the micro-particle image velocimetry (PIV) method. For the Newtonian fluid, the streamline was skewed more to the wall of the channel. The velocity profile of the non-Newtonian fluid was generally blunter than that of the Newtonian fluid. A highly oscillating wall shear stress (WSS) during the pulsatile phase may be attributed to such a bluntness of flow under the same wall shear rate condition with the Newtonian fluid. In addition, a highly viscous flow contributes to the variation in the WSS after passing through the stenosed structures. A similar tendency was observed in simulation results. Such a variation in the WSS was associated with plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.
Precise measurement of biophysical properties is important to understand the relation between these properties and the outbreak of cardiovascular diseases (CVDs). However, a systematic measurement for these biophysical parameters under in vivo conditions is nearly impossible because of complex vessel shape and limited practicality. In vitro measurements can provide more biophysical information, but in vitro exposure changes hemorheological properties. In this study, a hybrid system composed of an ultrasound system and microfluidic device is proposed for monitoring hemorheological and hemodynamic properties under more reasonable experimental conditions. Biophysical properties including RBC aggregation, viscosity, velocity and pressure of blood flows are simultaneously measured under various conditions to demonstrate the feasibility and performance of this measurement system. The proposed technique is applied to a rat extracorporeal loop which connects the aorta and jugular vein directly. As a result, the proposed system is found to measure biophysical parameters reasonably without blood collection from the rat and provided more detailed information. This hybrid system, combining ultrasound imaging and microfluidic techniques to ex vivo animal models, would be useful for monitoring the variations of biophysical properties induced by chemical agents. It can be used to understand the relation between biophysical parameters and CVDs.
Considering the role of viscosity in the dynamics of physical, chemical, and biological systems, accurate measurement of viscosity is essential. Although many conventional viscometers have been widely used, these conventional viscometers suffer from some drawbacks. In this study, a three-dimensional (3D) printed microfluidic viscometer was proposed based on the estimation of the pressure between two fluids to easily measure viscosity with small samples. The 3D printed microfluidic viscometer can be fabricated through amine-epoxy bonding on 3D printed blocks. By separately delivering samples and reference fluids into two inlets, an interfacial line could be induced. Based on the relation between the pressure ratio and the width of the reference flow, the viscosity (μ) of the sample can be estimated by measuring the relative width of the reference flow. The relation between the pressure and interfacial width between test samples and reference flows in the 3D printed microfluidic viscometers was analyzed by experiment and simulation to determine the effects of the mesh-like pattern of the 3D printed viscometers on the pressure estimation. To validate the proposed method, the viscosity values of glycerol mixtures measured by the 3D printed viscometer were compared with those measured by a conventional viscometer. As an application of the 3D printed viscometer, the viscosity curves for blood samples collected from diabetic and non-diabetic patients depending on their shear rates were compared. As expected, a high blood viscosity in the diabetic group was observed. Based on the experimental demonstrations, the 3D printed viscometer has strong potential to develop portable viscometers that can be translated to commercial outcomes.