Hiroshi Hirayama

Dr. Hiroshi Hirayama

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MDManh-Hiep Dao
Manh-Hiep Dao
KIKoichiro Ishibashi
Koichiro Ishibashi
TNThe-Anh Nguyen
The-Anh Nguyen
DBDuy-Hieu Bui
Duy-Hieu Bui
HHHiroshi Hirayama
Hiroshi Hirayama
XTXuan-Tu Tran
Xuan-Tu Tran
This article proposes a low cost of USD 72.5 BoM with a small size of water level monitoring IoT sensor without Ultra-Sonic level sensors. The power consumption for sensing and RF transmission is minimized to less than 100 μW in the manner of the Beat Sensor IoT system so that power is supplied by energy harvesting power supply using a card-size solar cell. Communication range can be reached 2 km using LoRa WAN and Quasi-isotropic Ω -Antenna. The system continuously measures the water level at a pond for 21 days without a battery, and the RMSE of the water level measurement reaches 2.5 mm. The practical evaluations show that this proposal can be applicable to several IoT systems for monitoring water levels.

8 June 2020 in Electronics
Verified
Journal Article
Open access
PDF file
AKAkihiko Kumazawa
Akihiko Kumazawa
YDYinliang Diao
Yinliang Diao
AHAkimasa Hirata
Akimasa Hirata
HHHiroshi Hirayama
Hiroshi Hirayama
The impedance variation of wireless power transfer (WPT) coils owing to the presence of the human body may result in mismatches, resulting in a decrease of the transmission efficiency. In addition, one of the decisive factors of the permissible transfer power in WPT systems is a compliance assessment with the guidelines/standards for human protection from electromagnetic fields. In our previous study, we reported that a shielded loop coil can potentially reduce human interaction with WPT coils. In this study, first, the rationale for this reduction is investigated with equivalent circuit models for a WPT system using a shielded loop coil operated in close proximity to the human body. We then conducted an equivalent circuit analysis considering the capacitance between the inner and outer conductors of the shielded loop coil, suggesting the stability of the impedance matching. From computational results, the mitigation capability of the shielded loop coil on impedance matching and transmission efficiency owing to the presence of the human body was verified for 6.78 MHz wireless power transfer. Additionally, the reduction of the specific absorption rate (SAR) with coils comprised of the shielded loop structure was confirmed in the presence of anatomically realistic human body models. The maximum transferable power was increased from 1.5 kW to 2.1 kW for the restrictions of the local SAR limit prescribed in the international safety guidelines/standard.

1 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
TATakaya Arai
Takaya Arai
HHHiroshi Hirayama
Hiroshi Hirayama
In this paper, a folded spiral resonator with a double-layered structure for near-field wireless power transfer is proposed. In near-field wireless power transfer, conjugate impedance matching is important to achieve high transfer efficiency. To achieve maximum available efficiency, it is common to connect a matching circuit to the antenna. However, the loss increases if a matching circuit is used. A coupling inductor with a resonant capacitor has the capability to adjust an imaginary part of the input impedance, whereas the folded spiral resonator has the capability to adjust both the imaginary and real parts of the input impedance. This resonator can achieve the maximum available efficiency without a matching circuit. This paper shows that the folded spiral resonator with a double-layered structure realizes high transfer efficiency compared to conventional models.

1 January 1994 in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A
Verified
Journal Article
Open access
HAHiroshi Akiyama
Hiroshi Akiyama
HOHideomi Ohtsubo
Hideomi Ohtsubo
MYMotohiko Yamada
Motohiko Yamada
HNHideharu Nakamura
Hideharu Nakamura
SMShinichi Matsuura
Shinichi Matsuura
YOYuji Ooka
Yuji Ooka

1 May 1995 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
KTKenichi Takakura
Kenichi Takakura
MUMasahiro Ueta
Masahiro Ueta
MIMasakazu Ichimiya
Masakazu Ichimiya
HHHiroshi Hirayama
Hiroshi Hirayama
TUToshio Ueno
Toshio Ueno
TOToshio Ohsaki
Toshio Ohsaki

3 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
XDXianyi Duan
Xianyi Duan
LJlan jq
lan jq
YDYinliang Diao
Yinliang Diao
Jose Gomez-TamesJose Gomez-Tames
Jose Gomez-Tames
HHHiroshi Hirayama
Hiroshi Hirayama
AHAkimasa Hirata
Akimasa Hirata
Wireless power transfer (WPT) systems have attracted considerable attention in relation to providing a reliable and convenient power supply. Among the challenges in this area are maintaining the performance of the WPT system with the presence of a human body and minimizing the induced physical quantities in the human body. This study proposes a magnetic resonant coupling WPT (MRC-WPT) system that utilizes a resonator with a grounded loop to mitigate its interaction with a human body and achieve a high-efficiency power transfer at a short range. Our proposed system is based on a grounded loop to reduce the leakage of the electric field, resulting in less interaction with the human body. As a result, a transmission efficiency higher than 70% is achieved at a transmission distance of approximately 25 cm. Under the maximum-efficiency conditions of the WPT system, the use of a resonator with a grounded loop reduces the induced electric field, the peak spatial-average specific absorption rate (psSAR), and the whole-body averaged SAR by 43.6%, 69.7%, and 65.6%, respectively. The maximum permissible input power values for the proposed WPT systems are 40 and 33.5 kW, as prescribed in the International Commission of Non-Ionizing Radiation Protection (ICNIRP) guidelines to comply with the limits for local and whole-body average SAR.