This article reviews recent standardization activities and scientific studies related to the assessment of human exposure to electromagnetic fields (EMF). The differences of human exposure standards and assessment of consumer products and medical applications are summarized. First, we reviewed human body modeling and tissue dielectric properties. Then, we explain the rationale of current exposure standards from the viewpoint of EMF and the standardization process for product compliance based on these exposure standards. The assessment of wireless power transfer, as an example of emerging wireless devices, and environmental EMFs in our daily lives are reviewed. Safety in magnetic resonance systems, where the EMF exposure is much larger than from typical consumer devices, is also reviewed. Finally, we summarize future research directions and research needs for EMF safety.
The averaged absorbed power density (APD) and temperature rise in body models with nonplanar surfaces were computed for electromagnetic exposure above 6 GHz. Different calculation schemes for the averaged APD were investigated. Additionally, a novel compensation method for correcting the heat convection rate on the air/skin interface in voxel human models was proposed and validated. The compensation method can be easily incorporated into bioheat calculations and does not require information regarding the normal direction of the boundary voxels, in contrast to a previously proposed method. The APD and temperature rise were evaluated using models of a two-dimensional cylinder and a three-dimensional partial forearm. The heating factor, which was defined as the ratio of the temperature rise to the APD, was calculated using different APD averaging schemes. Our computational results revealed different frequency and curvature dependences. For body models with curvature radii of >30 mm and at frequencies of >20 GHz, the differences in the heating factors among the APD schemes were small.
International organizations have collaborated to revise standards and guidelines for human protection from exposure to electromagnetic fields. In the frequency range of 6–300 GHz, the permissible spatially averaged epithelial/absorbed power density, which is primarily derived from thermal modeling, is considered the basic restriction. However, for the averaging methods of the epithelial/absorbed power density inside human tissues, only a few groups have presented calculated results obtained using different exposure conditions and numerical methods. Because experimental validation is extremely difficult in this frequency range, this paper presents the first intercomparison study of the calculated epithelial/absorbed power density inside a human body model exposed to different frequency sources ranging from 10–90 GHz. This intercomparison aims to clarify the difference in the calculated results caused by different numerical electromagnetic methods in dosimetry analysis from 11 research groups using planar skin models. To reduce the comparison variances caused by various key parameters, computational conditions (e.g., the antenna type, dimensions, and dielectric properties of the skin models) were unified. The results indicated that the maximum relative standard deviation (RSD) of the peak spatially averaged epithelial/absorbed power densities for one- and three-layer skin models were less than 17.49% and 17.39%, respectively, when using a dipole antenna as the exposure source. For the dipole array antenna, the corresponding maximum RSD increased to 32.49% and 42.55%, respectively. Under the considered exposure scenarios, the RSD in the spatially averaged epithelial/absorbed power densities decreased from 42.55% to 16.7% when the frequency was increased from 10–90 GHz. Furthermore, the deviation from the two equations recommended by the exposure guidelines for deriving the spatially averaged epithelial/absorptive power density was mostly within 1 dB. The fair agreement in the intercomparison results demonstrates that the variances of the spatially averaged epithelial/absorbed power densities calculated using planar skin models are marginal.
Recently, international exposure guidelines/standards for human protection from electromagnetic fields were revised. For frequencies between 6-300 GHz, the permissible incident power density is defined as the reference level, which is derived from a new metric “absorbed/epithelial power density” based on thermal modeling. However, only a few groups computed the power density and the resultant temperature rise at frequencies greater than 6 GHz, where their exposure conditions were different. This study presents the first intercomparison study of the incident power density and the resultant temperature rise in a human body exposed to different frequency sources ranging from 10 to 90 GHz. This intercomparison aims to clarify the main causes of numerical calculation errors in dosimetry analyses through objective comparison of computation results from six organizations using their numerical methods with various body and antenna models. The intercomparison results indicate that the maximum relative standard deviation (RSD) of peak spatially averaged incident power densities for dipole and dipole array antennas is less than 22.1% and 6.3%, respectively. The maximum RSD of the heating factor, which is defined as the ratio of the peak temperature elevation at the skin surface to the peak spatially averaged incident power density in free space, for dipole and dipole array antennas is less than 43.2% and 41.2%, respectively. The deviations in the heating factors caused by different body models and dielectric/thermal parameters are within 33.1% and 19.6% at 10 and 30 GHz, respectively, when the antenna-to-skin model distance is greater than 5 mm. Under this condition (>5 mm), the deviation in the heating factors caused by different antenna models at 30 GHz does not exceed 26.3%. The fair agreement among the intercomparison results demonstrates that numerical calculation errors of dosimetry analyses caused by the definition of spatially averaged incident power density are marginal.
This article reports on an intercomparison study on the effect of the incidence angle on the spatial average of incident power density (PD) and resultant temperature rise using computational and thermographic measurement approaches. Two definitions of the spatial average of incident PD—the peak spatial-average normal component of the Poynting vector and peak spatial-average norm of the Poynting vector—were compared. First, an intercomparison of incident PD and temperature rise in a layered skin model was conducted for a 4 × 4 dipole array antenna. The variations caused by antenna type, antenna-body distance, and skin model to these definitions were then discussed. The results revealed that both definitions are in good agreement and correlate with the peak temperature rise for small or moderate incidence angles. The heating factor was enhanced for transverse-magnetic-like polarized waves for peak spatial-average normal component of the Poynting vector for large-angle incidences because of the Brewster effect. The normal incidence scenario was confirmed to be essential for considering the peak skin temperature rise.