The main aim of this study is to comprehensively analyze the dynamics of land use and land cover (LULC) changes in the Bathinda region of Punjab, India, encompassing historical, current, and future trends. To forecast future LULC, the Cellular Automaton–Markov Chain (CA) based on artificial neural network (ANN) concepts was used using cartographic variables such as environmental, economic, and cultural. For segmenting LULC, the study used a combination of ML models, such as support vector machine (SVM) and Maximum Likelihood Classifier (MLC). The study is empirical in nature, and it employs quantitative analyses to shed light on LULC variations through time. The result indicates that the barren land is expected to shrink from 55.2 km2 in 1990 to 5.6 km2 in 2050, signifying better land management or increasing human activity. Vegetative expanses, on the other hand, are expected to rise from 81.3 km2 in 1990 to 205.6 km2 in 2050, reflecting a balance between urbanization and ecological conservation. Agricultural fields are expected to increase from 2597.4 km2 in 1990 to 2859.6 km2 in 2020 before stabilizing at 2898.4 km2 in 2050. Water landscapes are expected to shrink from 13.4 km2 in 1990 to 5.6 km2 in 2050, providing possible issues for water resources. Wetland regions are expected to decrease, thus complicating irrigation and groundwater reservoir sustainability. These findings are confirmed by strong statistical indices, with this study’s high kappa coefficients of Kno (0.97), Kstandard (0.95), and Klocation (0.97) indicating a reasonable level of accuracy in CA prediction. From the result of the F1 score, a significant issue was found in MLC for segmenting vegetation, and the issue was resolved in SVM classification. The findings of this study can be used to inform land use policy and plans for sustainable development in the region and beyond.
(1) Background: Radon concentrations in the environment are generally very low. However, radon concentrations can be high indoors and can cause some serious health issues. The main source of indoor radon (homes, buildings and other residential objects) can be soil under the house, while other sources can be construction materials, groundwater and natural gas. Radon accumulates mainly in the lower levels of the buildings (especially low-ventilated underground levels and basements). (2) Methods: in this paper, we have measured the indoor radon concentrations at 15 locations in various objects (basements and ground floor/1st floor rooms) in the area of northern Croatia. (3) Results: the results show a higher concentration of radon in the basement area in comparison to values measured in the ground floor and first-floor rooms. The arithmetic mean (AM) and geometric mean (GM) of basement rooms were 70.9 ± 38.8 Bq/m3 and 61.2 ± 2.2 Bq/m3 compared to ground floor and first-floor rooms 42.5 ± 30.8 Bq/m3 and 32.8 ± 2.9 Bq/m3, respectively. (4) Conclusions: results obtained (AM and GM values) are within the maximal allowed values (300 Bq/m3) according to the Euroatom Directive. However, there are periods when maximum radon concentration exceeds 300 Bq/m3. Indoor radon concentrations vary with the occupancy of the rooms and it is evident that the ventilation has significant effect on the reduction of concentration.
Given the concern for maintaining voltage stability in power systems integrated with renewable power systems due to a mismatch in generation and demand, there remains a need to invoke flexible alternating current transmission system (FACTS) devices in the distribution network. The present paper deals with identifying the locations of placement of a static var compensator in an experimental IEEE 14-bus system; the voltage drop in different buses in an IEEE 14-bus system is calculated by the standard formula. The total voltage drop in the network (TVDN) is also calculated as a reference. The ranking of buses in order of decreasing voltage drop is made, and the weak buses are identified as those showing the maximum or near-maximum voltage drop for the installation of a Static Var Compensator (SVC). The optimum usable size is calculated using a Genetic Algorithm approach to optimize the installation cost. After size optimization, installing a 2 MW solar generator is considered for the weak and most potential bus, which suffers from voltage drops or power loss. Based on the generator at the weakest bus, the total power loss in the network is calculated and compared with a similar method to assess the efficiency of the proposed model. Thus, the voltage stability enhancement problem is solved by applying a Genetic algorithm (GA) to optimize SVC size and using the Total Voltage Drop in Network (TVDN) method to identify weak buses in the systems. It is found that the performance of the proposed system is comparable with another existing system. It is further observed that a gain in power loss to 6.56% is achievable by adopting the proposed strategy, and the gain is better than the other system.
Because textile industries are intensely water-consuming and generate a huge quantity of wastewater, the present study examines the scope of using solar thermal technology to treat wastewater from textile industries. A hybrid technology, comprising a compound parabolic concentrator-based solar thermal system in conjunction with a Membrane Distillation (MD) system, is experimented with for wastewater treatment in textile industries. The MD system requires a water temperature of around 90 °C for efficient functioning. The advanced MD technology using waste heat combined with solar heat to meet the system’s thermal load is technologically evaluated for an experimental textile industry in India. Moreover, the present study critically analyses the techno economics of the proposed hybrid technology. A detailed financial analysis has revealed that, besides technological superiority, the recommended technology is also financially rewarding for wastewater treatment in the textile industry. To cope with the delayed payback period, financial incentives are recommended so that the system becomes a lucrative technological option.
Intensive agricultural practices lead to a deterioration in soil quality, causing a decline in farm productivity and quality, and disturbing the ecosystem balance in command areas. To achieve sustainable production and implement effective soil management strategies, understanding the state and spatial variability of soil quality is essential. The study aims to enhance the understanding of soil quality variability and provide actionable insights for sustainable soil management. In this regard, principal component analysis (PCA) and digital soil mapping were used to assess and map the spatial variability of the soil quality index (SQI) in the Cauvery command area, Mandya district, Karnataka, India. A total of 145 georeferenced soil samples were drawn at 0–15 cm depth and analyzed for physico-chemical properties. PCA was used to reduce the dataset into a minimum dataset as eight important soil indicators and to determine relative weightage factors, which were used for assessing SQI with linear and non-linear scoring methods. For spatial assessment of SQI, the random forest algorithm with environmental covariates was used to map eight soil indicators selected in the minimum dataset. The soil property maps were subjected to linear and non-linear scoring, followed by multiplying with corresponding weightage factors and summation to produce SQI maps. Results reveal that values of SQI calculated using linear scoring, range from 0.10 to 0.64, with a mean of 0.39, while non-linear scoring exhibits a wider range of 0.12 to 0.78 and a mean of 0.48. With a slight higher sensitivity index of 6.5, non-linear scoring proved to be the better scoring method compared to linear scoring. Spatial assessment shows that the R2 and LCC between the calculated and predicted SQI were higher for non-linear scoring (0.66 and 0.66) compared to linear scoring (0.60 and 0.65). The SQI maps reveal high spatial variability with more than 40 percent of soils classified as moderate-to-low index. The soils with low SQI were distributed in eastern parts, whereas western parts exhibited high-to-very-high soil quality. To achieve production goals and improve soil quality in the eastern region, sustainable soil and crop management strategies must be developed, and their effects on soil quality should be assessed.
The present study focuses on finding potential sites for ecotourism development using GIS and remote-sensing-based weightage sum overlay techniques in Western Rajasthan, India. Ecotourism is one of the fastest growing and revenue-making sectors incorporating a sustainable future. Western Rajasthan has a broad scope to develop tourism-based activity in various ways, mainly through cultural heritage, historical and archaeological wonders, and rare wildlife. Weightage sum overlay analysis is a useful and simple tool to compare each thematic layer. These values are based on various factors and understanding taken during the study. For this purpose, different data types have been taken from the USGS website. Arc GIS 10.8 and ERDAS Imagine software 2015 have been utilized to process the data. This research incorporates seven thematic layers, i.e., elevation, proximity to streams, land use/cover, population density, road connectivity, proximity to protected areas, and heritage hotspots. Based on the physical and cultural characteristics of Western Rajasthan, the weightage of each thematic layer has been decided, which is finally overlaid using Arc GIS software. After processing all the thematic layers, we finally get an outcome in the form of a suitability map. The final suitability map represents five suitability classes that divide the total area into the following categories, very high (37.31%), high (26.85%), moderate (7.89%), low (0.83%), and very low (27.12%), which represents the potential of ecotourism in Western Rajasthan.