Bozena Dorota Hrynyszyn

Prof. Bozena Dorota Hrynyszyn

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2019 in Energy Efficiency
Verified
Journal Article
Closed access
PDF file
LFLaurina Felius
Laurina Felius
FDFredrik Dessen
Fredrik Dessen
BHBozena Dorota Hrynyszyn
Bozena Dorota Hrynyszyn

23 April 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
DBDavid Bjelland
David Bjelland
JBJohannes Brozovsky
Johannes Brozovsky
BHBozena Dorota Hrynyszyn
Bozena Dorota Hrynyszyn

3 November 2020 in Buildings
Verified
Journal Article
Open access
PDF file
LFLaurina Felius
Laurina Felius
Mohamed HamdyMohamed Hamdy
Mohamed Hamdy
FDFredrik Dessen
Fredrik Dessen
BHBozena Dorota Hrynyszyn
Bozena Dorota Hrynyszyn
Improving the energy efficiency of existing buildings by implementing building automation control strategies (BACS) besides building envelope and energy system retrofitting has been recommended by the Energy Performance of Buildings Directive (EPBD) 2018. This paper investigated this recommendation by conducting a simulation-based optimization to explore cost-effective retrofitting combinations of building envelope, energy systems and BACS measures in-line with automation standard EN 15232. Two cases (i.e., a typical single-family house and apartment block) were modeled and simulated using IDA Indoor Climate and Energy (IDA-ICE). The built-in optimization tool, GenOpt, was used to minimize energy consumption as the single objective function. The associated difference in life cycle cost, compared to the reference design, was calculated for each optimization iteration. Thermal comfort of the optimized solutions was assessed to verify the thermal comfort acceptability. Installing an air source heat pump had a greater energy-saving potential than reducing heat losses through the building envelope. Implementing BACS achieved cost-effective energy savings up to 24%. Energy savings up to 57% were estimated when BACS was combined with the other retrofitting measures. Particularly for compact buildings, where the potential of reducing heat losses through the envelope is limited, the impact of BACS increased. BACS also improved the thermal comfort.

4 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
Zhiyong TianZhiyong Tian
Zhiyong Tian
Shicong ZhangShicong Zhang
Shicong Zhang
JDJie Deng
Jie Deng
BHBozena Dorota Hrynyszyn
Bozena Dorota Hrynyszyn
As the temperature in the summer period in Norway has been always moderate, little study on the indoor comfort of typical Norwegian residential buildings in summer seasons can be found. Heat waves have attacked Norway in recent years, including in 2018 and 2019. Zero energy buildings, even neighborhoods, have been a hot research topic in Norway. There is overheating risk in typical Norwegian residential buildings without cooling devices installed under these uncommon weather conditions, like the hot summers in 2018 and 2019. Three weather scenarios consisting of present-day weather data, 2050 weather data, and 2080 weather data are investigated in this study. The overheating risk of a typical Norwegian residential building is evaluated under these three weather scenarios. 72 scenarios are simulated in this study, including different orientations, window-to-wall ratios, and infiltration rates. Two different overheating evaluation criteria and guidelines, the Passive House Planning Package (PHPP) and the CIBSE TM 59, are compared in this study.

1 January 2020 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
LFLaurina Felius
Laurina Felius
Mohamed HamdyMohamed Hamdy
Mohamed Hamdy
BHBozena Dorota Hrynyszyn
Bozena Dorota Hrynyszyn
FDF Dessen
F Dessen
In this study, the energy savings and cost-effectiveness of building automation measures in a retrofitting context are evaluated for a Norwegian single-family house. In addition, two methods for calculating savings from implementing building automation control systems (BACS) are compared: energy performance simulation and the BACS factor method proposed in EN 15232. Four retrofitting packages and four automation levels are combined to create 16 model versions. This study shows that BACS can increase energy savings and improve indoor comfort when implemented as a retrofitting measure. However, the relative impact on energy savings of building automation decreases when the delivered energy is lower. In addition, the impact of building automation on the energy savings is low compared to the effect of retrofitting the building envelope. When only BACS are implemented, savings up to 21% can be achieved, but when an integrated solution is implemented savings up to 60% can be achieved. Finally, some directions for future work are suggested.

30 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
TATony-Andreas Arntsen
Tony-Andreas Arntsen
BHBozena Dorota Hrynyszyn
Bozena Dorota Hrynyszyn
Window design affects the overall performance of a building. It is important to include window design during the initial stages of a project since it influences the performance of daylight and thermal comfort as well as the energy demand for heating and cooling. The Norwegian building code facilitates two alternative methods for achieving a sufficient daylight, and only guidelines for adequate indoor thermal comfort. In this study, a typical Norwegian residential building was modeled to investigate whether the criteria and methods facilitate consistent and good performance through different scenario changes and furthermore, how the national regulations compare to European standards. A better insulated and more air-tight building has usually a lower annual heating demand, with only a marginal decrease in the daylight performance when the window design is unchanged. A more air-tight construction increases the risk of overheating, even in cold climates. This study confirms that a revision of the window design improves the overall performance of a building, which highlights the importance of proper window design. The pursuit of lower energy demand should not be at the expense of indoor thermal comfort considering the anticipated future weather conditions. This study indicates that criteria for thermal comfort and daylight, if clearly defined, can affect the energy demand for heating and cooling, as well as the indoor climate positively, and should be taken into account at the national level. A comparison between the national regulations and the European standards was made, and this study found that the results are not consistent.