Background: A validity and reliability assessment of inertial measurement unit (IMU)-derived joint angular kinematics during walking is a necessary step for motion analysis in the lower extremity prosthesis user population. This study aimed to assess the accuracy and reliability of an inertial measurement unit (IMU) system compared to an optical motion capture (OMC) system in transtibial prosthesis (TTP) users. Methods: Thirty TTP users were recruited and underwent simultaneous motion capture from IMU and OMC systems during walking. Reliability and validity were assessed using intra- and inter-subject variability with standard deviation (S.D.), average S.D., and intraclass correlation coefficient (ICC). Results: The intra-subject S.D. for all rotations of the lower limb joints were less than 1° for both systems. The IMU system had a lower mean S.D. (o), as seen in inter-subject variability. The ICC revealed good to excellent agreement between the two systems for all sagittal kinematic parameters. Conclusion: All joint angular kinematic comparisons supported the IMU system’s results as comparable to OMC. The IMU was capable of precise sagittal plane motion data and demonstrated validity and reliability to OMC. These findings evidence that when compared to OMC, an IMU system may serve well in evaluating the gait of lower limb prosthesis users.
Purpose The purpose of this study was to evaluate function and performance of unilateral trans-tibial prosthesis users wearing an affordable liner in three types of socket designs. Methods Five unilateral trans-tibial amputees participated, were provided an Affordable Ethyl-Vinyl-Acetate Roll-On liner (AERO) roll-on liner with patella tendon bearing (PTB) prosthesis, PE-Lite liner with PTB prosthesis, and an (AERO) liner with total-surface bearing (TSB) prosthesis. A battery of outcome measures; step-counts, socket comfort score (SCS), orthotics prosthetics user survey (OPUS) and socket pressure measurement during walking were administered. Results Comparisons of step-counts indicated that PTB-AERO (3604 +/- 815) was not significantly different than PTB-PE-Lite (3386 +/- 942). Mean SCS was 9.2 +/- .83 and 7.2 +/- 2.1 for PTB-AERO and PTB-PE-Lite. A 6.6% decrease in mean peak pressure was observed between PTB-PE-Lite and TSB-AERO, and 3.2% difference between PTB-PE-Lite and PTB-AERO. Conclusion An affordable ($20 USD) and sustainably fabricated prosthesis liner was created and evaluated in trans-tibial prosthesis users. These initial results garner preliminary support for use of the AERO prosthetic liner and continued research.
Step counts and oxygen consumption have yet to be reported during the 2-min walk test (2MWT) test in persons with lower-limb amputations (LLA). The purpose of this study was to determine step counts and oxygen consumption during the 2MWT in LLA. Thirty-five men and women walked for two minutes as quickly as possible while wearing activity monitors (ActiGraph Link on the wrist (LW) and ankle (LA), Garmin vivofit®3 on the wrist (VW) and ankle (VA), and a modus StepWatch on the ankle (SA), and a portable oxygen analyzer. The StepWatch on the ankle (SA) and the vivofit3 on the wrist (VW) had the least error and best accuracy of the activity monitors studied. While there were no significant differences in distance walked, oxygen consumption (VO2) or heart rate (HR) between sexes or level of amputation (p > 0.05), females took significantly more steps than males (p = 0.034), and those with unilateral transfemoral amputations took significantly fewer steps than those with unilateral transtibial amputations (p = 0.023). The VW and SA provided the most accurate step counts among the activity monitors and were not significantly different than hand counts. Oxygen consumption for all participants during the 2MWT was 8.9 ± 2.9 mL/kg/min, which is lower than moderate-intensity activity. While some may argue that steady-state activity has not yet been reached in the 2MWT, it may also be possible participants are not walking as fast as they can, thereby misclassifying their performance to a lower standard.
Purpose: To investigate the accuracy of consumer-grade wrist-worn activity monitors during over ground walking in persons using lower-limb prosthetics. Method: Thirty-two participants using lower-limb prosthetics (age = 49.7 ± 14.0 yrs, height = 176.1 ± 11.6 cm, weight = 87.8 ± 21.1 kg) were fitted with a Polar Loop, Fitbit Flex, MOVEBAND, Garmin Vivofit, and a Fitbit Charge on the right and left wrists as well as an Omron HJ-113 pedometer on the right and left hip, then walked 140 m at a self-selected pace on an indoor flat surface. Results: There were no significant differences between any of the respective right and left monitors, p > 0.05. When comparing step counts with actual step counts, Polar Loop (p = 0.001), Fitbit Flex (p = 0.001), and MOVEBAND (p = 0.001) were significantly lower than actual step counts. No significant differences existed between the remaining monitors and actual step counts (p > 0.05). Omron incurred the least error (0.6%), followed by Garmin Vivofit (1.3%) and Fitbit Charge (3.6%), with greatest error in the MOVEBAND (21.4%) and Polar Loop (13.1%). Bland–Altman plots suggest Garmin Vivofit to have the least error along with tightest agreement among the wrist-worn activity monitors Conclusion: When considering the use of consumer-grade wrist-worn activity monitors for assessing step counts in persons using lower-limb prostheses, the Garmin Vivofit seems to be the best option followed by Fitbit Charge.
1 April 2014 in JPO Journal of Prosthetics and Orthotics
It is important that all individuals obtain sufficient physical activity to increase health and fitness for the reduction of risk factors associated with cardiovascular disease. Pedometers are a means by which one can monitor and assess physical activity levels. The objective of this study was to assess the accuracy of three commercially available pedometers in persons with lower-limb amputations. Thirty-nine participants were fitted with an Omron HJ-112, a New Lifestyles 800, and a Digiwalker SW-701 on the right side of the hip, then walked at a self-selected pace on a carpeted level surface for 200 m. Repeated-measures (RM) analysis of variance (ANOVA) indicated a significant difference between the pedometers and the actual counts (ACs). Whereas the HJ-112 (mean [SD], 312.5 [38.3] steps) and the NL-800 (307.2 [35.1] steps) were not significantly different from AC (314.7 [73.9] steps), the SW-701 (255.57 [8.5] steps) significantly underestimated step counts, p < 0.05. Bland-Altman plots indicated the HJ-112 had the best agreement with AC, followed by the NL-800. Percentage error was lowest in the HJ-112 (0.69%), followed by NL-800 (2.4%), with the SW-701 eliciting the greatest error (18.8%). The HJ-12 and the NL-800 are viable options for persons with lower-limb amputations seeking to assess and/or monitor their physical activity levels.
(1) Background: A sustainable casting system that combines the use of a polystyrene bag, a prosthetic liner and a vacuum system was developed to reduce fabrication time while maintaining comfort for the trans-tibial prosthesis user. (2) Methods: Eight prosthetists (28.7 ± 8.25 years old) fit ten trans-tibial prosthesis wearers (46 ± 12.4 years old) with two types of total surface bearing (TSB) prostheses; a polystyrene bead (PS) prosthesis and a plaster of paris (POP) prosthesis. Duration of casting and combined mean peak pressure was measured at six locations on the residual limb using Force Sensing Resistors (FSR). A pressure uniformity score (%) was determined. Socket Comfort Scale (SCS) was also measured. (3) Results: Duration of casting for the POP method was 64.8 ± 9.53 min and 7.8 ± 2 min for the PS method, (p = 0.006). Pressure uniformity in the POP prosthesis was 79.3 ± 6.54 and 81.7 ± 5.83 in the PS prosthesis (p = 0.027). SCS in both prosthesis types were equivalent. (4) Conclusion: A rapid fit PS prosthesis was developed, with significantly shorter duration than the traditional POP method. Socket pressure uniformity was confirmed and improved in the PS method. Socket comfort was equal between the two prothesis types.