3 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Jutima RattanakochJutima Rattanakoch
Jutima Rattanakoch
MSManunchaya Samala
Manunchaya Samala
WLWeerawat Limroongreungrat
Weerawat Limroongreungrat
Gary GuerraGary Guerra
Gary Guerra
KTKittichai Tharawadeepimuk
Kittichai Tharawadeepimuk
SSSarit Suwanmana Suwanmana
Sarit Suwanmana Suwanmana
Background: A validity and reliability assessment of inertial measurement unit (IMU)-derived joint angular kinematics during walking is a necessary step for motion analysis in the lower extremity prosthesis user population. This study aimed to assess the accuracy and reliability of an inertial measurement unit (IMU) system compared to an optical motion capture (OMC) system in transtibial prosthesis (TTP) users. Methods: Thirty TTP users were recruited and underwent simultaneous motion capture from IMU and OMC systems during walking. Reliability and validity were assessed using intra- and inter-subject variability with standard deviation (S.D.), average S.D., and intraclass correlation coefficient (ICC). Results: The intra-subject S.D. for all rotations of the lower limb joints were less than 1° for both systems. The IMU system had a lower mean S.D. (o), as seen in inter-subject variability. The ICC revealed good to excellent agreement between the two systems for all sagittal kinematic parameters. Conclusion: All joint angular kinematic comparisons supported the IMU system’s results as comparable to OMC. The IMU was capable of precise sagittal plane motion data and demonstrated validity and reliability to OMC. These findings evidence that when compared to OMC, an IMU system may serve well in evaluating the gait of lower limb prosthesis users.

5 June 2022 in Disability and Rehabilitation
Verified
Journal Article
Closed access
YMYusuke Miyata
Yusuke Miyata
KSKazuhiko Sasaki
Kazuhiko Sasaki
Gary GuerraGary Guerra
Gary Guerra
Jutima RattanakochJutima Rattanakoch
Jutima Rattanakoch
Purpose The purpose of this study was to evaluate function and performance of unilateral trans-tibial prosthesis users wearing an affordable liner in three types of socket designs. Methods Five unilateral trans-tibial amputees participated, were provided an Affordable Ethyl-Vinyl-Acetate Roll-On liner (AERO) roll-on liner with patella tendon bearing (PTB) prosthesis, PE-Lite liner with PTB prosthesis, and an (AERO) liner with total-surface bearing (TSB) prosthesis. A battery of outcome measures; step-counts, socket comfort score (SCS), orthotics prosthetics user survey (OPUS) and socket pressure measurement during walking were administered. Results Comparisons of step-counts indicated that PTB-AERO (3604 +/- 815) was not significantly different than PTB-PE-Lite (3386 +/- 942). Mean SCS was 9.2 +/- .83 and 7.2 +/- 2.1 for PTB-AERO and PTB-PE-Lite. A 6.6% decrease in mean peak pressure was observed between PTB-PE-Lite and TSB-AERO, and 3.2% difference between PTB-PE-Lite and PTB-AERO. Conclusion An affordable ($20 USD) and sustainably fabricated prosthesis liner was created and evaluated in trans-tibial prosthesis users. These initial results garner preliminary support for use of the AERO prosthetic liner and continued research.

31 January 2020 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
KSKazuhiko Sasaki
Kazuhiko Sasaki
Gary GuerraGary Guerra
Gary Guerra
Jutima RattanakochJutima Rattanakoch
Jutima Rattanakoch
YMYusuke Miyata
Yusuke Miyata
SSSharmila Suntharalingam
Sharmila Suntharalingam
This research sought to develop a fabricable prosthetic liner that could be fabricable, intuitive, and a cost-effective means of providing advanced prosthetics in developing settings. An affordable ethyl-vinyl-acetate roll-on (AERO) liner for permitting a total surface bearing suction socket design was created and provided to a single participant for in vivo outcome measurements. The liner was fabricated from locally produced low-density ethyl-vinyl-acetate (EVA) foam. A liner fabrication process was developed and described, and one participant was provided 3 mm and 6 mm AERO liner variants for outcome evaluations. Six-minute walk test, residual limb temperature, and socket comfort score (SCS) while in AERO liner were collected. Thirty-day step counts of AERO liner with prosthesis and thermoplastic elastomer (TPE) liner with prosthesis were collected. The results of in vivo evaluations indicate increased speed, slightly higher residuum temperature, and increased comfort of the 6 mm AERO liner. Pedometer tallied step counts for the AERO liner and TPE liner prostheses were similar. The 6 mm AERO liner provided the best comfort and function of the two thicknesses in liners, and step count data indicated that the volume of patient activity was similar to when wearing the TPE liner prosthesis. Roll-on fabricable low-cost liners offer an affordable means of providing total surface bearing suction prostheses for resource limited environments (RLE). A prosthetist or technician can use the existing skills and lab to create liners.

25 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MSManunchaya Samala
Manunchaya Samala
PRPhilip Rowe
Philip Rowe
Jutima RattanakochJutima Rattanakoch
Jutima Rattanakoch
Gary GuerraGary Guerra
Gary Guerra
Validation testing is a necessary step for inertial measurement unit (IMU) motion analysis for research and clinical use. Optical tracking systems utilize marker models which must be precise in measurement and mitigate skin artifacts. Prosthesis wearers present challenges to optical tracking marker model choice. Seven participants were recruited and underwent simultaneous motion capture from two marker sets; Plug in Gait (PiG) and the Strathclyde Cluster Model (SCM). Variability of joint kinematics within and between subjects was evaluated. Variability was higher for PiG than SCM for all parameters. The within-subjects variability as reported by the average standard deviation (SD), was below 5.6° for all rotations of the hip on the prosthesis side for all participants for both methods, with an average of 2.1° for PiG and 2.5° for SCM. Statistically significant differences in joint parameters caused by a change in the protocol were evident in the sagittal plane (p < 0.05) on the amputated side. Trans-tibial gait analysis was best achieved by use of the SCM. The SCM protocol appeared to provide kinematic measurements with a smaller variability than that of the PiG. Validation studies for prosthesis wearer populations must reconsider the marker protocol for gold standard comparisons with IMUs.

24 August 2024 in Scientific Data
Verified
Journal Article
Open access
PDF file
MSManunchaya Samala
Manunchaya Samala
Jutima RattanakochJutima Rattanakoch
Jutima Rattanakoch
GGGary Guerra
Gary Guerra
KTKittichai Tharawadeepimuk
Kittichai Tharawadeepimuk
ANAmpika Nanbancha
Ampika Nanbancha
WLWeerawat Limroongreungrat
Weerawat Limroongreungrat
Motion analysis has played a crucial role in providing gait analysis for prosthetic users. Understanding kinematics in motion analysis allows for the evaluation of the effects of prostheses and the development of a prosthetic component design that aids in walking within the community. However, there are currently limited open datasets available to study the locomotion of individuals using transtibial prostheses, and most research studies involve a limited number of participants. This dataset shows 30 transtibial prosthesis users walking comfortably on a 10-meter walkway inside a laboratory. We offer a set of joint ankles obtained from the inertial measurement unit (IMU) signals in CSV file format. We also provide the optical motion capture (OMC) system’s raw trajectory marker data in C3D file format and joint angle in CSV file format. This open dataset will provide resources for professionals interested in amputee gait for research in amputee gait detection and tracking algorithms. Moreover, the data will be the control data for comparison in developing advanced prosthetic components.

22 June 2026 in Computers in Biology and Medicine
Verified
Journal Article
Open access
WNWisavaporn Niamsang
Wisavaporn Niamsang
Gary GuerraGary Guerra
Gary Guerra
WKWorapan Kusakunniran
Worapan Kusakunniran
HAHarit Apidech
Harit Apidech
PKPattaraporn Kongsatan
Pattaraporn Kongsatan
MSManunchaya Samala
Manunchaya Samala
The 3D marker-based optical system (MBS) is the benchmark for biomechanical measurement, but it is limited by cost, time, and accessibility. OpenCap, a web-based 3D markerless motion capture system, has the potential to address these limitations, although its validity and reliability in transfemoral prosthesis users remain unclear. This study aimed to evaluate the validity and within-session reliability of OpenCap in 31 transfemoral prosthetic users (mean age 44.52 ± 14.90 years). Participants performed walking trials on a dual-belt treadmill at a self-selected comfortable speed, while kinematic data were collected simultaneously using OpenCap and MBS. Statistical analyses included Intraclass Correlation Coefficients (ICC), Statistical Parametric Mapping (SPM1d), and Root Mean Square Error (RMSE). OpenCap showed excellent agreement for spatiotemporal parameters (ICC >0.99 with RMSE 10°). For time-series kinematics, SPM1d analysis identified significant differences (p < 0.05) in joint kinematics across the gait cycle, particularly at the knee and ankle. Within-session reliability was good to excellent (ICC >0.75) for spatiotemporal parameters and several sagittal- and frontal-plane kinematic variables. Lower reliability (ICC = 0.584-0.733) was observed in transverse-plane measures on both sides and in some ankle measures on the prosthetic side, particularly hip rotation ROM on the prosthetic side. OpenCap provides valid spatiotemporal data and may serve as an accessible tool for gait assessment. However, joint kinematic accuracy requires improvement. Future research should focus on optimizing tracking for the complex prosthetic movements.