Lime mud, a kind of industrial waste that produced in paper mill, was proposed as CO2 sorbent in calcium looping process. The carbonation performance of the lime mud was investigated in a dual‐fixed bed reactor (DFR) and a thermogravimetric analyzer (TGA). The carbonation kinetics of the lime mud in the chemical reaction controlled stage was analyzed by a surface reaction‐controlled kinetic model. The results show that the lime mud presents much poorer carbonation performance during the chemical reaction controlled stage compared with the limestone, mainly due to the high content of chlorine in the lime mud. A prewash treatment process was used to decrease the chlorine content to mitigate the sintering of the lime mud when calcined at high temperature. After prewash treatment, the prewashed lime mud shows much higher CO2 capture capacity during the chemical reaction controlled stage compared with the lime mud. A prolonged carbonation process successfully further enhances the microstructure and improves the carbonation performance of the prewashed lime mud in the chemical reaction controlled stage. The lime mud can be effectively used as CO2 sorbent in calcium looping process after prewash treatment and the following prolonged carbonation treatment.
Using polyethylene glycol as the fuel and dispersant, highly reactive MgO-stabilized CaO sorbent was synthesized by solution combustion, with a CO 2 capture capacity of 0.40 g(CO 2 )/g(sorbent) after 20 cycles.
1 January 2021 in Chinese Journal of Chemical Engineering
This study theoretically explored the effects of parameter settings on thermoacoustic oscillations with a low-order model. Three factors were explored—combustor length, inlet gas temperature and thermal power. The research findings indicate that optimizing the parameter settings can yield better thermoacoustic oscillation suppression results. The sound pressure amplitude decreased from 3.2 × 105 Pa to 2.1 × 105 Pa as the combustor length increased from 1.2 m to 6.0 m. The triggering time increased from 0.32 s to 0.91 s when the combustion chamber length increased. The climb rate declined from 23.38 × 105 Pa/s to 3.75 × 105 Pa/s when the combustor length was elongated. The sound pressure amplitude decreased from 3.44 × 105 Pa to 2.4 × 105 Pa as the gas temperature rose from 0 to 100 °C. The triggering time and climb rate variation tendency were similar when the gas temperature increased—both declined as the gas temperature rose. The sound pressure amplitude experienced a slight fluctuation when the thermal power rose. However, the triggering time decreased from 0.26 s to 0.043 s when the thermal power improved. The climb rate increased from 18.72 × 105 Pa/s to 27.65 × 105 Pa/s when the thermal power rose. The oscillation frequency presented was completely different in three cases that had different wavelengths and oscillation intensities. The triggering time and climb rate fluctuated extensively in varying conditions, and the above two factors were interrelated and contradictory to each other when thermoacoustic oscillation was excited. This study explored parameters’ effects on triggering time and climb rate, thereby providing references for constructing a model-based control system for thermoacoustic oscillation feedback control.
Biomass fuels play an important role in the field of fluidized bed combustion, but due to the diversity and uncertainty of fuels, there are usually some problems of high CO emission that cannot be directly solved by combustion adjustment. In this paper, a 75 t/h biomass fluidized bed was taken as the research object. It was observed from the field test that the gas incomplete combustion loss reached 12.13% when mono-combustion of wheat straw was conducted, and the CO concentration in the exhaust gas exceeded 30k ppm. Combined with the CPFD numerical simulation, the combustion characteristics and influence of secondary air layout on CO reduction performance were discussed in detail. The results revealed that the gas temperature gradually increased along furnace height under the initial condition, and the maximum temperature was more than 1000 °C at furnace outlet. The air curtain of the secondary air jets was insufficient, and the wheat straw rose rapidly as it entered into the furnace. By arranging adjacent secondary air ports above each fuel-feeding inlet, the residence time of particles in the furnace could be significantly increased, thus, the furnace temperature distribution was more reasonable and the CO emission was reduced by 58.6%.