Gianluigi Giuliani

Dr. Gianluigi Giuliani

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ANAlfredo Niro
Alfredo Niro
GSGiancarlo Sborgia
Giancarlo Sborgia
LLLuisa Lampignano
Luisa Lampignano
GGGianluigi Giuliani
Gianluigi Giuliani
Fabio Stefano CastellanaFabio Stefano Castellana
Fabio Stefano Castellana
FBFrancesco Boscia
Francesco Boscia
Background: Retinal microvasculature assessment at capillary level may potentially aid the evaluation of early microvascular changes due to hypertension. We aimed to investigate associations between the measures obtained using optical coherence tomography (OCT) and OCT-angiography (OCT-A) and hypertension, in a southern Italian older population. Methods: We performed a cross-sectional analysis from a population-based study on 731 participants aged 65 years+ subdivided into two groups according to the presence or absence of blood hypertension without hypertensive retinopathy. The average thickness of the ganglion cell complex (GCC) and the retinal nerve fiber layer (RNFL) were measured. The foveal avascular zone area, vascular density (VD) at the macular site and of the optic nerve head (ONH) and radial peripapillary capillary (RPC) plexi were evaluated. Logistic regression was applied to assess the association of ocular measurements with hypertension. Results: GCC thickness was inversely associated with hypertension (odds ratio (OR): 0.98, 95% confidence interval (CI): 0.97–1). A rarefaction of VD of the ONH plexus at the inferior temporal sector (OR: 0.95, 95% CI: 0.91–0.99) and, conversely, a higher VD of the ONH and RPC plexi inside optic disc (OR: 1.07, 95% CI: 1.04–1.10; OR: 1.04, 95% CI: 1.02–1.06, respectively) were significantly associated with hypertension. Conclusion: A neuroretinal thinning involving GCC and a change in capillary density at the peripapillary network were related to the hypertension in older patients without hypertensive retinopathy. Assessing peripapillary retinal microvasculature using OCT-A may be a useful non-invasive approach to detect early microvascular changes due to hypertension.

18 February 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GSGiancarlo Sborgia
Giancarlo Sborgia
ANAlfredo Niro
Alfredo Niro
TTTiziana Tritto
Tiziana Tritto
Valeria AlbanoValeria Albano
Valeria Albano
LSLuigi Sborgia
Luigi Sborgia
Giovanni AlessioGiovanni Alessio
Giovanni Alessio
Background: Despite the high closure rate of large macular hole (LMH) after surgery, visual recovery is often worse than expected. Microperimetric biofeedback can improve visual function in macular pathologies. We evaluated the efficacy of biofeedback on macular function after successful inverted flap technique for LMH. Methods: In this prospective comparative study, 26 patients after LMH surgical closure were enrolled. The whole sample was equally divided into two groups. In Group 1 (trained), patients underwent a double cycle of microperimetric biofeedback, using structured light stimulus plus acoustic tone; in Group 2 (control), patients underwent scheduled visits. We analyzed visual acuity, retinal sensitivity at central 12° (macular sensitivity, MS) and 4° (central macular sensitivity, CMS), and fixation stability over twelve months. Results: Visual acuity improved mainly in the trained group, without any significant differences between the groups (p > 0.05). Only after training did MS significantly improve (p = 0.01). CMS more significantly improved in the trained (p < 0.001) than the control group (p < 0.01) (Group 1 vs. 2, p = 0.004). Only in the trained group did fixation significantly improve (3 months, p ≤ 0.03; 12 months, p ≤ 0.01). An equality test on matched data confirmed a greater significant improvement of CMS (p ≤ 0.02) at all follow-up and fixation (p ≤ 0.02) at last follow-up after training. Conclusions: Microperimetric biofeedback consolidates and increases the improvement of retinal sensitivity and fixation gained after successful inverted flap technique.

1 February 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
SGSamuele Gigliola
Samuele Gigliola
GSGiancarlo Sborgia
Giancarlo Sborgia
ANAlfredo Niro
Alfredo Niro
CPCarmela Palmisano
Carmela Palmisano
PPPasquale Puzo
Pasquale Puzo
Giovanni AlessioGiovanni Alessio
Giovanni Alessio
Introduction: We described a one-handed rotational phacoemulsification technique to decrease phaco time and power, and surgical stress on the cornea in eyes with different types of cataract. Methods: In this technique a single sutureless corneal incision was made without any side-port incision. After hydrodissection and hydrodelamination were performed, a phaco tip was positioned in contact with the nucleus beside the capsulorhexis edge. By using a peristaltic pump, phacoemulsification was started with high levels of vacuum to keep the probe tip on the edge of the lens and to ensure the rotation of the nucleus, and with low ultrasound energy. The torsional mode used required less occlusion time and volume of fluid. The inclination of the tip was modified to 45-degree, directing it toward the lens center. So the nucleus was aspirated from the periphery toward the center by a rotational movement. Results: The eye in the technical video had a NC4-NO4 cataract. The preoperative vision in this eye was 20/100 with no improvement with refraction. On postoperative day 1, visual acuity had improved to 20/20. We recorded low intraoperative parameters including ultrasound time (21.4 sec), phacoemulsification power (73%), balanced salt solution used (31 mL) and cumulative dissipated energy (7.27) at the conclusion of the case. After 1 month, Central Corneal Thickness changed from 504 μm to 516 μm, and Endothelial Cell Loss was 1.15%. Conclusion: This technique uses a single clear corneal incision, high vacuum and low ultrasound power to reduce the exposition to excessive surgical maneuvers, fluid turbulence and ultrasound energy.