Pasquale Puzo

Pasquale Puzo

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ANAlfredo Niro
Alfredo Niro
GSGiancarlo Sborgia
Giancarlo Sborgia
LLLuisa Lampignano
Luisa Lampignano
GGGianluigi Giuliani
Gianluigi Giuliani
Fabio Stefano CastellanaFabio Stefano Castellana
Fabio Stefano Castellana
FBFrancesco Boscia
Francesco Boscia
Background: Retinal microvasculature assessment at capillary level may potentially aid the evaluation of early microvascular changes due to hypertension. We aimed to investigate associations between the measures obtained using optical coherence tomography (OCT) and OCT-angiography (OCT-A) and hypertension, in a southern Italian older population. Methods: We performed a cross-sectional analysis from a population-based study on 731 participants aged 65 years+ subdivided into two groups according to the presence or absence of blood hypertension without hypertensive retinopathy. The average thickness of the ganglion cell complex (GCC) and the retinal nerve fiber layer (RNFL) were measured. The foveal avascular zone area, vascular density (VD) at the macular site and of the optic nerve head (ONH) and radial peripapillary capillary (RPC) plexi were evaluated. Logistic regression was applied to assess the association of ocular measurements with hypertension. Results: GCC thickness was inversely associated with hypertension (odds ratio (OR): 0.98, 95% confidence interval (CI): 0.97–1). A rarefaction of VD of the ONH plexus at the inferior temporal sector (OR: 0.95, 95% CI: 0.91–0.99) and, conversely, a higher VD of the ONH and RPC plexi inside optic disc (OR: 1.07, 95% CI: 1.04–1.10; OR: 1.04, 95% CI: 1.02–1.06, respectively) were significantly associated with hypertension. Conclusion: A neuroretinal thinning involving GCC and a change in capillary density at the peripapillary network were related to the hypertension in older patients without hypertensive retinopathy. Assessing peripapillary retinal microvasculature using OCT-A may be a useful non-invasive approach to detect early microvascular changes due to hypertension.

1 July 2023 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
GBGiacomo Boscia
Giacomo Boscia
PVPasquale Viggiano
Pasquale Viggiano
FMFederica Marzulli
Federica Marzulli
MGMaria Oliva Grassi
Maria Oliva Grassi
PPPasquale Puzo
Pasquale Puzo
FBFrancesco Boscia
Francesco Boscia
Purpose: To assess the long-term morpho-functional retinal and choroidal changes in chronic central serous chorioretinopathy (cCSC) pachychoroid eyes in response to continuous oral eplerenone (EPL) treatment. Methods: This pilot study was conducted on patients with unilateral exudative cCSC. We enrolled a total of 17 exudative cCSC and 17 non-exudative fellow eyes of 17 patients. Baseline best-corrected visual acuity (BCVA) and anatomical (structural optical coherence tomography [OCT] and OCT angiography) parameters in both eyes were collected at baseline. Follow-up data were collected at 6, 12, and 48 months after initiation of EPL treatment. Results: (i) Exudative cCSC eyes: Compared with baseline (0.34± 0.13 LogMAR), BCVA significantly improved at follow-up examinations (6 months: 0.28± 0.13 LogMAR, p=0.039; 12 months: 0.22± 0.11 LogMAR, p=0.025; 48 months: 0.21± 0.08 LogMAR, p=0.028). Furthermore, there was a significant reduction from baseline in all structural OCT parameters (subretinal fluid and subfoveal choroidal thickness [SFCT]; p< 0.05). (ii) Non-exudative fellow eyes: There was no significant change in BCVA. There was a significant reduction from baseline in SFCT and choriocapillaris flow deficit percentage (p< 0.05). Conclusion: In this pilot study, continuous oral EPL therapy in cCSC pachychoroid eyes resulted in long-term morpho-functional improvement. The beneficial effect of EPL occurred within the first year and was maintained after four years. Based on these preliminary observations, EPL may be effective in the exudative forms of CSC.

1 August 2022 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Open access
PDF file
EPElisabetta Pallara
Elisabetta Pallara
SCSergio Cotugno
Sergio Cotugno
GGGiacomo Guido
Giacomo Guido
GVGelsomino De Vita
Gelsomino De Vita
ARAurelia Ricciardi
Aurelia Ricciardi
Francesco Di GennaroFrancesco Di Gennaro
Francesco Di Gennaro
: Loa loa is a filarial nematode responsible for loiasis, endemic to West–Central Africa south of the Sahara and transmitted by flies. This study reports a case of L. loa in the vitreous cavity of the eye of a young patient, along with an in-depth literature review. A 22-year-old woman from Cameroon who migrated from Cameroon to Italy was referred to the Emergency Ophthalmology Department at Policlinico di Bari in July 2021 with the presence of a moving parasite in the subconjunctiva of the left eye. A recent onset of a papular lesion on the dorsal surface of the right wrist and a nodular lesion in the scapular region were detected. L. loa filariasis was diagnosed based on anamnestic data, clinical and paraclinical signs, and a parasitological test confirming the presence of microfilariae in two blood samples collected in the morning of two different days. Because of the unavailability of diethylcarbamazine (DEC), albendazole (ALB) 200 mg twice daily was administered for 21 days. A mild exacerbation of pruritus occurred during treatment, but resolved with the use of an antihistamine. A single dose of 12 mg ivermectin was prescribed at the end of the treatment with albendazole. Unlike other endemic parasite infections, L. loa is not included in the Global Program to Eliminate Lymphatic Filariasis, because it is not mentioned in the WHO and CDC list of neglected tropical diseases. This can result in an overall risk of lack of attention and studies on loiasis, with lack of data on global burden of the disease.

24 March 2022 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PPPasquale Puzo
Pasquale Puzo
Francesco D'OriaFrancesco D'Oria
Francesco D'Oria
AIAurelio Imburgia
Aurelio Imburgia
CICosimo Incandela
Cosimo Incandela
ASAlessandra Sborgia
Alessandra Sborgia
GAGiovanni Alessio
Giovanni Alessio
Purpose: To evaluate and compare the outcomes of live surgery (LS) and no-live surgery (NLS) on cataract surgery with implantation of different types of intraocular lenses (IOLs). Methods: Retrospective, contralateral eye, case series of patients that underwent cataract surgery in live or non-live view during two consecutive editions of national meetings. Both eyes of the same patients were implanted with the same IOL, one in LS and the other in NLS. Results: 108 eyes of 54 patients, aged between 50 and 82 (72 ± 8.2) and implanted with different types of IOLs, were reviewed. Both eyes in each patient were well matched at baseline in terms of intraocular biometric characteristics, corneal curvature and endothelial cell density (ECD) (p > 0.05). There are no statistically significant differences between the biometric and topographic parameters, aberrometric data and the loss of ECD in the post-operative outcomes (p > 0.05). However, comparing the different types of IOLs, there is a significant loss of ECD in eyes implanted with a toric IOL during LS (p = 0.0014 and p = 0.04, in 2017 and 2018 edition respectively). Conclusions: In this series of live cataract surgery, eyes operated in LS or NLS have comparable outcomes, underlying the importance and the benefits of live view in terms of medical education and the low-risk of complications. Nevertheless, we have found a significant increase in ECD loss in patients implanted with toric IOLs during LS.

1 February 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
SGSamuele Gigliola
Samuele Gigliola
GSGiancarlo Sborgia
Giancarlo Sborgia
ANAlfredo Niro
Alfredo Niro
CPCarmela Palmisano
Carmela Palmisano
PPPasquale Puzo
Pasquale Puzo
Giovanni AlessioGiovanni Alessio
Giovanni Alessio
Introduction: We described a one-handed rotational phacoemulsification technique to decrease phaco time and power, and surgical stress on the cornea in eyes with different types of cataract. Methods: In this technique a single sutureless corneal incision was made without any side-port incision. After hydrodissection and hydrodelamination were performed, a phaco tip was positioned in contact with the nucleus beside the capsulorhexis edge. By using a peristaltic pump, phacoemulsification was started with high levels of vacuum to keep the probe tip on the edge of the lens and to ensure the rotation of the nucleus, and with low ultrasound energy. The torsional mode used required less occlusion time and volume of fluid. The inclination of the tip was modified to 45-degree, directing it toward the lens center. So the nucleus was aspirated from the periphery toward the center by a rotational movement. Results: The eye in the technical video had a NC4-NO4 cataract. The preoperative vision in this eye was 20/100 with no improvement with refraction. On postoperative day 1, visual acuity had improved to 20/20. We recorded low intraoperative parameters including ultrasound time (21.4 sec), phacoemulsification power (73%), balanced salt solution used (31 mL) and cumulative dissipated energy (7.27) at the conclusion of the case. After 1 month, Central Corneal Thickness changed from 504 μm to 516 μm, and Endothelial Cell Loss was 1.15%. Conclusion: This technique uses a single clear corneal incision, high vacuum and low ultrasound power to reduce the exposition to excessive surgical maneuvers, fluid turbulence and ultrasound energy.

Verified
Journal Article
Open access
PDF file
Francesco D'OriaFrancesco D'Oria
Francesco D'Oria
PPPasquale Puzo
Pasquale Puzo
CICosimo Incandela
Cosimo Incandela
ASAlessandra Sborgia
Alessandra Sborgia
SGsamuele gigliola
samuele gigliola
Giovanni AlessioGiovanni Alessio
Giovanni Alessio
The aim of the study was to visualize and evaluate the characteristics and depth of the demarcation line with anterior segment optical coherence tomography (AS-OCT) after epithelium-off iontophoresis corneal collagen cross-linking (epi-off I-CXL). In this prospective, consecutive, single center study 18 eyes of 18 patients with keratoconus were involved. One month after epi-off I-CXL, all the patients underwent an AS-OCT scan to search for a demarcation line and its characteristics. The corneal stromal demarcation line was identified in all the eyes. Mean depth of the corneal stromal demarcation line was 261.8 ± 46.7 μm (range: 184 to 362 μm), at 56.7 ± 12% corneal depth. In conclusion, epi-off I-CXL determines a demarcation line that can be visualized with AS-OCT, which seems clearly distinguishable and similar to that created in standard CXL.