TZU-CHING SHIH

Prof. TZU-CHING SHIH

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
THTzung-Chi Huang
Tzung-Chi Huang
CHChien-Yi Hsiao
Chien-Yi Hsiao
CCChun-Ru Chien
Chun-Ru Chien
JLJi-An Liang
Ji-An Liang
TSTZU-CHING SHIH
TZU-CHING SHIH
GZGeoffrey G Zhang
Geoffrey G Zhang
Currently, the inhomogeneity of the pulmonary function is not considered when treatment plans are generated in thoracic cancer radiotherapy. This study evaluates the dose of treatment plans on highly-functional volumes and performs functional treatment planning by incorporation of ventilation data from 4D-CT. Eleven patients were included in this retrospective study. Ventilation was calculated using 4D-CT. Two treatment plans were generated for each case, the first one without the incorporation of the ventilation and the second with it. The dose of the first plans was overlapped with the ventilation and analyzed. Highly-functional regions were avoided in the second treatment plans. For small targets in the first plans (PTV < 400 cc, 6 cases), all V5, V20 and the mean lung dose values for the highly-functional regions were lower than that of the total lung. For large targets, two out of five cases had higher V5 and V20 values for the highly-functional regions. All the second plans were within constraints. Radiation treatments affect functional lung more seriously in large tumor cases. With compromise of dose to other critical organs, functional treatment planning to reduce dose in highly-functional lung volumes can be achieved.

5 July 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TSTZU-CHING SHIH
TZU-CHING SHIH
JCJeon-Hor Chen
Jeon-Hor Chen
DLDongxu Liu
Dongxu Liu
KNKe Nie
Ke Nie
LSLizhi Sun
Lizhi Sun
MSMin-Ying Su
Min-Ying Su
This study presents a finite element-based computational model to simulate the three-dimensional deformation of a breast and fibroglandular tissues under compression. The simulation was based on 3D MR images of the breast, and craniocaudal and mediolateral oblique compression, as used in mammography, was applied. The geometry of the whole breast and the segmented fibroglandular tissues within the breast were reconstructed using triangular meshes by using the Avizo 6.0 software package. Due to the large deformation in breast compression, a finite element model was used to simulate the nonlinear elastic tissue deformation under compression, using the MSC.Marc software package. The model was tested in four cases. The results showed a higher displacement along the compression direction compared to the other two directions. The compressed breast thickness in these four cases at a compression ratio of 60% was in the range of 5-7 cm, which is a typical range of thickness in mammography. The projection of the fibroglandular tissue mesh at a compression ratio of 60% was compared to the corresponding mammograms of two women, and they demonstrated spatially matched distributions. However, since the compression was based on magnetic resonance imaging (MRI), which has much coarser spatial resolution than the in-plane resolution of mammography, this method is unlikely to generate a synthetic mammogram close to the clinical quality. Whether this model may be used to understand the technical factors that may impact the variations in breast density needs further investigation. Since this method can be applied to simulate compression of the breast at different views and different compression levels, another possible application is to provide a tool for comparing breast images acquired using different imaging modalities--such as MRI, mammography, whole breast ultrasound and molecular imaging--that are performed using different body positions and under different compression conditions.

27 August 2012 in Experimental Hematology & Oncology
Verified
Journal Article
Open access
PDF file
CHChien-Yi Ho
Chien-Yi Ho
HLHsiu-Mei Liao
Hsiu-Mei Liao
CTCHIH-YEN TU
CHIH-YEN TU
CHChih-Yang Huang
Chih-Yang Huang
CSChuen-Ming Shih
Chuen-Ming Shih
TSTZU-CHING SHIH
TZU-CHING SHIH
The computational fluid dynamics method, which provides an estimation of the pressure drop in the airway before and after the stent implantation, is proposed in this study. This method is based on the finite volume model. The pressure field was solved by the Navier-Stokes equations. The proposed methodology was evaluated in seven health people (control group) and in fourteen patients who were assigned in two groups, in which one was tracheal stenosis and the other was bronchial stenosis. The results showed that the pressure drop after tracheal stent implantation became significantly smaller. For bronchial stent implantation cases, the airway resistance improved insignificantly.

1 March 2014 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
FCFong-Lin Chen
Fong-Lin Chen
THTzyy-Leng Horng
Tzyy-Leng Horng
TSTZU-CHING SHIH
TZU-CHING SHIH
This study presents a computational fluid dynamics (CFD) model to simulate the three-dimensional airflow in the trachea before and after the vascular ring surgery (VRS). The simulation was based on CT-scan images of the patients with the vascular ring diseases. The surface geometry of the tracheal airway was reconstructed using triangular mesh by the Amira software package. The unstructured tetrahedral volume meshes were generated by the ANSYS ICEM CFD software package. The airflow in the tracheal airway was solved by the ESI CFD-ACE+ software package. Numerical simulation shows that the pressure drops across the tracheal stenosis before and after the surgery were 0.1789 and 0.0967 Pa, respectively, with the inspiratory inlet velocity 0.1 m/s. Meanwhile, the improvement percentage by the surgery was 45.95%. In the expiratory phase, by contrast, the improvement percentage was 40.65%. When the inspiratory velocity reached 1 m/s, the pressure drop became 4.988~Pa and the improvement percentage was 43.32%. Simulation results further show that after treatment the pressure drop in the tracheal airway was significantly decreased, especially for low inspiratory and expiratory velocities. The CFD method can be applied to quantify the airway pressure alteration and to evaluate the treatment outcome of the vascular ring surgery under different respiratory velocities.

22 December 2023 in Otolaryngology–Head and Neck Surgery
Verified
Journal Article
Closed access
TWTang‐Chuan Wang
Tang‐Chuan Wang
TSTZU-CHING SHIH
TZU-CHING SHIH
CCChin-Kuo Chen
Chin-Kuo Chen
Vivian Chia-Rong HsiehVivian Chia-Rong Hsieh
Vivian Chia-Rong Hsieh
DLDan Jae Lin
Dan Jae Lin
CTChon‐Haw Tsai
Chon‐Haw Tsai

1 December 2016 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
KLKuan-Yu Lin
Kuan-Yu Lin
TSTZU-CHING SHIH
TZU-CHING SHIH
SCSzu-Hsien Chou
Szu-Hsien Chou
ZCZhen-Ye Chen
Zhen-Ye Chen
CHChung-Ho Hsu
Chung-Ho Hsu
CHChien-Yi Ho
Chien-Yi Ho
The purpose of this study is to use the coronary computed tomography angiography (CCTA) to simulate the coronary blood flow with different theoretical flow models by using not only the computation fluid dynamics (CFD) method, but also additional patient boundary conditions obtained with echocardiography, and evaluate the feasibility of simulated fractional flow reserve (FFRCTS), compared with the invasive CTA-based FFR. The laminar and three turbulence models (k-ε(k-epsilon), k-ω(k-omega), SST (Menter's shear stress transport)) were implemented to predict coronary blood flow. The study investigates an ideal stenosis model and six patients, with invasive FFR measurements. Three-dimensional reconstructions of coronary arteries of six subjects were performed from CCTA images of 320-detector scanner. The measured velocity profile of the left ventricular outflow tract from the echocardiography was employed for the inlet velocity in simulation. The pressure waveform of the patient aortic blood flow was used as the pressure profile at the outlet. With simulations, we found that the maximum velocity in the stenotic coronary artery reached about 395 cm s−1, which was about 2.4 times faster than the inlet velocity of 165 cm s−1 for the patient with coronary stenosis diagnosed 50%–75% on CTA. The pressure drop across the stenosis was about 28 mmHg. Meanwhile, the value of FFRCTS using the laminar flow pattern was 0.788 closely to its invasive FFR of 0.79. In conclusion, this study demonstrated that the CFD method has moderate more blood flow information to assess the hemodynamic significance of the coronary blood flow and calculate the non-invasive FFRCTS values, which were very close to those measured with invasive FFR.