Syed Ali

Dr. Syed Ali


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2009 in Sensors
Verified
Journal Article
Open access
PDF file
AFAlimujiang Fulati
Alimujiang Fulati
SASyed Ali
Syed Ali
MRMuhammad Riaz
Muhammad Riaz
GAGul Amin
Gul Amin
ONOmer Nour
Omer Nour
Magnus  WillanderMagnus Willander
Magnus Willander
ZnO nanotubes and nanorods grown on gold thin film were used to create pH sensor devices. The developed ZnO nanotube and nanorod pH sensors display good reproducibility, repeatability and long-term stability and exhibit a pH-dependent electrochemical potential difference versus an Ag/AgCl reference electrode over a large dynamic pH range. We found the ZnO nanotubes provide sensitivity as high as twice that of the ZnO nanorods, which can be ascribed to the fact that small dimensional ZnO nanotubes have a higher level of surface and subsurface oxygen vacancies and provide a larger effective surface area with higher surface-to-volume ratio as compared to ZnO nanorods, thus affording the ZnO nanotube pH sensor a higher sensitivity. Experimental results indicate ZnO nanotubes can be used in pH sensor applications with improved performance. Moreover, the ZnO nanotube arrays may find potential application as a novel material for measurements of intracellular biochemical species within single living cells.

1 March 2012 in Sensors
Verified
Journal Article
Open access
PDF file
SASyed Ali
Syed Ali
ZIZafar Ibupoto
Zafar Ibupoto
MKMuhammad Kashif
Muhammad Kashif
UHUda Hashim
Uda Hashim
Magnus  WillanderMagnus Willander
Magnus Willander
In the present work zinc oxide nanoflakes (ZnO-NF) structures with a wall thickness around 50 to 100 nm were synthesized on a gold coated glass substrate using a low temperature hydrothermal method. The enzyme uricase was electrostatically immobilized in conjunction with Nafion membrane on the surface of well oriented ZnO-NFs, resulting in a sensitive, selective, stable and reproducible uric acid sensor. The electrochemical response of the ZnO-NF-based sensor vs. a Ag/AgCl reference electrode was found to be linear over a relatively wide logarithmic concentration range (500 nM to 1.5 mM). In addition, the ZnO-NF structures demonstrate vast surface area that allow high enzyme loading which results provided a higher sensitivity. The proposed ZnO-NF array-based sensor exhibited a high sensitivity of ~66 mV/ decade in test electrolyte solutions of uric acid, with fast response time. The sensor response was unaffected by normal concentrations of common interferents such as ascorbic acid, glucose, and urea.

22 September 2011 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
MKMuhammad Kashif
Muhammad Kashif
SASyed Ali
Syed Ali
MAMd. Eaqub Ali
Md. Eaqub Ali
HAH. I. Abdulgafour
H. I. Abdulgafour
UHU. Hashim
U. Hashim
ZHZ. Hassan
Z. Hassan

27 October 2011 in Biosensors
Verified
Journal Article
Open access
PDF file
ZIZafar Ibupoto
Zafar Ibupoto
SASyed Ali
Syed Ali
KKKimleang Khun
Kimleang Khun
CCChan Oeurn Chey
Chan Oeurn Chey
ONOmer Nour
Omer Nour
MWMagnus Willander
Magnus Willander
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed.

1 October 2011 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
MFMuhammad Fakhar-e-Alam
Muhammad Fakhar-e-Alam
SASyed Ali
Syed Ali
ZIZafar Ibupoto
Zafar Ibupoto
KKKhun Kimleang
Khun Kimleang
MAM. Atif
M. Atif
MWMagnus Willander
Magnus Willander

29 August 2011 in Sensors
Verified
Journal Article
Open access
PDF file
SASyed Ali
Syed Ali
TATasuif Aijazi
Tasuif Aijazi
KAKent Axelsson
Kent Axelsson
ONOmer Nour
Omer Nour
Magnus  WillanderMagnus Willander
Magnus Willander
This paper presents a prototype wireless remote glucose monitoring system interfaced with a ZnO nanowire arrays-based glucose sensor, glucose oxidase enzyme immobilized onto ZnO nanowires in conjunction with a Nafion® membrane coating, which can be effectively applied for the monitoring of glucose levels in diabetics. Global System for Mobile Communications (GSM) services like General Packet Radio Service (GPRS) and Short Message Service (SMS) have been proven to be logical and cost effective methods for gathering data from remote locations. A communication protocol that facilitates remote data collection using SMS has been utilized for monitoring a patient’s sugar levels. In this study, we demonstrate the remote monitoring of the glucose levels with existing GPRS/GSM network infra-structures using our proposed functionalized ZnO nanowire arrays sensors integrated with standard readily available mobile phones. The data can be used for centralized monitoring and other purposes. Such applications can reduce health care costs and allow caregivers to monitor and support to their patients remotely, especially those located in rural areas.