Chaoping  Zhang

Chaoping Zhang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
CZChaoping Zhang
Chaoping Zhang
RGRobert Gallichan
Robert Gallichan
DBDavid Budgett
David Budgett
DMDaniel McCormick
Daniel McCormick
This paper presents a capacitive pressure sensor interface circuit design in 180 nm XH018 CMOS technology for an implantable capacitive pressure sensor, which has a wireless power supply and wireless data transfer function. It integrates full-bridge rectifiers, shorting control switches, low-dropout regulators, bandgap references, analog front end, single slope analog to digital converter (ADC), I2C, and an RC oscillator. The low-dropout regulators regulate the wireless power supply coming from the rectifier and provide a stable and accurate 1.8 V DC voltage to other blocks. The capacitance of the pressure sensor is sampled to a discrete voltage by the analog front end. The single slope ADC converts the discrete voltage into 11 bits of digital data, which is then converted into 1 kbps serial data out by the I2C block. The “1” of serial data is modulated to a 500 kHz digital signal that is used to control the shorting switch for wireless data transfer via inductive back scatter. This capacitive pressure sensor interface IC has a resolution of 0.98 mmHg (1.4 fF), average total power consumption of 7.8 mW, and ±3.2% accuracy at the worst case under a −20 to 80 °C temperature range, which improves to ±0.86% when operated between 20 and 60 °C.

3 March 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CZChaoping Zhang
Chaoping Zhang
RGRobert Gallichan
Robert Gallichan
DLDixon P. Leung
Dixon P. Leung
DBDavid Budgett
David Budgett
DMDaniel McCormick
Daniel McCormick
This paper presents a system-on-a-chip (SoC) for pressure sensors in 180nm CMOS technology. It can interface with a capacitive pressure sensor with an inductive wireless power supply and data transmission via load-shift-keying (LSK). It integrates an analog front end (AFE), bandgap references, delta-sigma ADC, I2C, RC oscillator, low-dropout regulators (LDOs), shorting control switches and full-bridge rectifier. An external coil receives wireless power which is rectified and regulated to 1.8V by the full-bridge rectifier and LDOs. The AFE samples the capacitance change of the pressure sensor to a voltage that is converted into 19-bit digital data by the delta-sigma ADC, which is then converted into 43Hz per sample serial data by the I2C block. A temperature sensor is included, and 19-bit measurements are transmitted in serial with capacitance data. Serial data is transmitted wirelessly using LSK. This SoC has a measured accuracy of 1mmHg between 575mmHg to 900mmHg absolute with a wireless power supply and wireless data transfer.

13 June 2019 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CZChaoping Zhang
Chaoping Zhang
SHS. M. Rezaul Hasan
S. M. Rezaul Hasan
This paper describes a new dosimeter, which is composed of a Floating-Gate-Radiation-Field-Effect-Transistor (FGRADFET) sensor and novel absorbed-dose and dose-rate readout circuit. It is a single-chip implementation employing a standard single-poly 130nm CMOS technology. The FGRADFET extends the floating-gate as an extra silicon-area (60µm × 200µm) of poly-over-field-oxide that acts as a catchment to sense the radiation from the environment. There is also a parallel array of 16 PMOS transistors (1µm × 2µm each) at the edge of the field-oxide catchment-area to charge the floating-gate by the Fowler-Nordheim tunneling effect prior to the sensor deployment. Thus, no bias voltage is needed for the floating-gate (FG) transistors during the irradiation. A cascode current-mirror, a reference FGRADFET and 16 reference PMOS transistors are employed to compensate temperature effects and read the FG voltage of the FGRADFET sensor, which is proportional to the total absorbed dose. A further processing circuit for the FG voltage output is also designed to extract the slope of the FG voltage (the dose-rate). These circuits include differentiator, pre-amplify buffer, chopper-amplifier, low-pass filter and double-ended-to-single-ended output amplifier. A measured average sensitivity of around 3.86 mV/rad was achieved for x-ray irradiation. It consumes 320 µW in detecting the dose-rate with a 1 rad/min. 10 rad/min measurement range corresponding to the single-ended output ranging from 220 mV to 960 mV.

1 January 2020 in Integration
Verified
Journal Article
Closed access
CZChaoping Zhang
Chaoping Zhang
RGRobert Gallichan
Robert Gallichan
DBDavid M. Budgett
David M. Budgett
DMDaniel McCormick
Daniel McCormick

11 December 2018 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
CZChaoping Zhang
Chaoping Zhang
SHS. M. Rezaul Hasan
S. M. Rezaul Hasan

1 October 2019
Verified
Conference Paper
Closed access
CZChaoping Zhang
Chaoping Zhang
RGR. Gallichan
R. Gallichan
SLS. Lapshev
S. Lapshev
DBD. M. Budgett
D. M. Budgett
DMD. McCormick
D. McCormick