Czesław Bywalski

Dr. Czesław Bywalski

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
CBCzesław Bywalski
Czesław Bywalski
MDMichal Drzazga
Michal Drzazga
MKMaciej Kaźmierowski
Maciej Kaźmierowski
MKMieczysław Kamiński
Mieczysław Kamiński
The article presents experimental tests of a new type of composite bar that has been used as shear reinforcement for concrete beams. In the case of shearing concrete beams reinforced with steel stirrups, according to the theory of plasticity, the plastic deformation of stirrups and stress redistribution in stirrups cut by a diagonal crack are permitted. Tensile composite reinforcement is characterized by linear-elastic behavior throughout the entire strength range. The most popular type of shear reinforcement is closed frame stirrups, and this type of Fiber Reinforced Polymer (FRP) shear reinforcement was the subject of research by other authors. In the case of FRP stirrups, rupture occurs rapidly without the shear reinforcement being able to redistribute stress. An attempt was made to introduce a quasi-plastic character into the mechanisms transferring shear by appropriately shaping the shear reinforcement. Experimental material tests covered the determination of the strength and deformability of straight Glass Fiber Reinforced Polymer (GFRP) bars and GFRP headed bars. Experimental studies of shear reinforced beams with GFRP stirrups and GFRP headed bars were carried out. This allowed a direct comparison of the shear behavior of beams reinforced with standard GFRP stirrups and a new type of shear reinforcement: GFRP headed bars. Experimental studies demonstrated that GFRP headed bars could be used as shear reinforcement in concrete beams. Unlike GFRP stirrups, these bars allow stress redistribution in bars cut by a diagonal crack.

1 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
CBCzesław Bywalski
Czesław Bywalski
MKMaciej Kaźmierowski
Maciej Kaźmierowski
MKMieczysław Kamiński
Mieczysław Kamiński
MDMichal Drzazga
Michal Drzazga
The paper presents the results of tests for flexural tensile strength (fct,fl) and fracture energy (Gf) in a three-point bending test of prismatic beams with notches, which were made of steel fibre reinforced high-strength concrete (SFRHSC). The registration of the conventional force–displacement (F–δ) relationship and unconventional force-crack tip opening displacement (CTOD) relationship was made. On the basis of the obtained test results, estimations of parameters fct,fl and Gf in the function of fibre reinforcement ratio were carried out. The obtained results were applied to building and validating a numerical model with the use of the finite element method (FEM). A non-linear concrete damaged plasticity model CDP was used for the description of the concrete. The obtained FEM results were compared with the experimental ones that were based on the assumed criteria. The usefulness of the flexural tensile strength and fracture energy parameters for defining the linear form of weakening of the SFRHSC material under tension, was confirmed. Own equations for estimating the flexural tensile strength and fracture energy of SFRHSC, as well as for approximating deflections (δ) of SFRHSC beams as the function of crack tip opening displacement (CTOD) instead of crack mouth opening displacement (CMOD), were proposed.

3 May 2020 in Buildings
Verified
Journal Article
Open access
PDF file
CBCzesław Bywalski
Czesław Bywalski
MDMichal Drzazga
Michal Drzazga
MKMieczysław Kamiński
Mieczysław Kamiński
MKMaciej Kaźmierowski
Maciej Kaźmierowski
This paper investigates composite reinforcement with regard to its use as longitudinal reinforcement. The methods used to calculate the shear strength of concrete members reinforced with fibre-reinforced polymer (FRP) bars are analysed. The main parameters having a bearing on the shear strength of beams reinforced with composite bars are defined. A comparative analysis of the shear strength calculating algorithms provided in the available design recommendations concerning FRP reinforcement and formulas derived by others researchers is carried out. A synthesis of the research to date on sheared concrete members reinforced longitudinally with FRP bars is made. The results of the studies relating to shear strength are compared with the theoretical results yielded by the considered algorithms. A new approach for estimating the shear capacity of support zones reinforced longitudinally with FRP bars without shear reinforcement was proposed and verified. A satisfactory level of model fit was obtained—the best among the available proposals. Taking into account the extended base of destructive testing results, the estimation of the shear strength in accordance with the proposed model can be used as an accompanying (non-destructive) method for the empirical determination of shear resistance of longitudinally reinforced FRP bars.

29 August 2024 in Przegląd Budowlany
Verified
Journal Article
Closed access
DZDawid Zmyślony
Dawid Zmyślony
CBCzesław Bywalski
Czesław Bywalski
Aktualna norma PN-EN 1992-1-1 nie określa ograniczeńdotyczących smukłości słupów, umożliwiając projektowaniebardzo smukłych słupów, w których efekty II rzędu odgrywająistotną rolę. Można je wyznaczać metodami uproszczonymi (nominalnejsztywności i nominalnej krzywizny) lub metodą ogólnąopartą na nieliniowej analizie geometrycznej. Chociaż metodaogólna jest rzadko stosowana ze względu na swoją pracochłonność,pozwala na dokładniejsze oszacowanie efektów II rzędu,które są mniejsze w przypadku bardzo smukłych słupów niżwyniki metod uproszczonych. Artykuł porównuje efekty II rzęduuzyskane metodami uproszczonymi i metodą ogólną, wykazując,że metoda ogólna pozwala na optymalne zwymiarowaniezbrojenia w bardzo smukłych słupach oraz w słupach wysokichhal magazynowych

29 August 2024 in Przegląd Budowlany
Verified
Journal Article
Closed access
RARyszard Antonowicz
Ryszard Antonowicz
CBCzesław Bywalski
Czesław Bywalski
Przedmiotem pracy są pomosty o konstrukcji stalowej,żelbetowej i zespolonej wag samochodowych. Wagi wykonywanesą w różnych konfiguracjach, dostosowanych do obciążeńi możliwości transportowych. Z uwagi na rozmiary ważonych pojazdówciężarowych pomosty scala się w konstrukcję o szerokościwynoszącej najczęściej 3,0 m i długości 12, 14 lub 18 m. Wagio konstrukcji stalowej i zespolonej stalowo-żelbetowej są lżejszeod żelbetowych, jednak są bardziej wrażliwe na negatywne oddziaływanieśrodowiska. Obciążenie wag ma charakter cykliczny.W pracy opisano niektóre aspekty projektowania pomostówwag z uwzględnieniem ich projektowanego okresu użytkowania.Przedstawiono podstawowe założenia w zakresie przyjmowanychdo obliczeń oddziaływań pionowych, poziomych i dynamicznych.W pracy zidentyfikowano też sytuacje obliczeniowei wskazano rodzaje kombinacji, które należy uwzględnić w sprawdzaniustanów granicznych nośności i użytkowalności. Poruszonotematykę ograniczeń transportowych, obciążeń montażowychi liczby cykli obciążeń (obciążenia zmęczeniowe).

29 August 2024 in Przegląd Budowlany
Verified
Journal Article
Closed access
CBCzesław Bywalski
Czesław Bywalski
WPWojciech Pawlak
Wojciech Pawlak
Przedmiotem analizy są strunobetonowe dźwigarydachowe systemu P70 (SBn-I-65/15). Produkowano je w wersjiumożliwiającej wzmocnienie nadbetonem ułożonym międzyprefabrykowanymi płytami dachowymi, dzięki czemu uzyskiwanopełną projektowaną nośność. W trakcie oględzin analizowanegoobiektu stwierdzono, iż nadbeton taki wykonano, jednaknie w obrębie świetlików kalenicowych, gdzie wykonano wyłącznienadbeton spadkowy. Z tego względu odcinek pod świetlikamijest krytyczny z punktu widzenia bezpieczeństwa konstrukcji.Brak nadbetonu jest również powodem znaczących ugięć dźwigarów.W pracy przedstawiono wyniki oceny stanu technicznego,badań, pomiarów geodezyjnych ugięć i sprawdzających obliczeństatyczno-wytrzymałościowych oraz sposób wzmocnienia dźwigarów,umożliwiający jego realizację na czynnym obiekcie