H.P. Kok

Dr. H.P. Kok

Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam,Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CLC. M. van Leeuwen
C. M. van Leeuwen
AOArlene L. Oei
Arlene L. Oei
Johannes Hans CrezeeJohannes Hans Crezee
Johannes Hans Crezee
ABA. Bel
A. Bel
NFNicolaas Franken
Nicolaas Franken
H.P. KokH.P. Kok
H.P. Kok
Prediction of radiobiological response is a major challenge in radiotherapy. Of several radiobiological models, the linear-quadratic (LQ) model has been best validated by experimental and clinical data. Clinically, the LQ model is mainly used to estimate equivalent radiotherapy schedules (e.g. calculate the equivalent dose in 2 Gy fractions, EQD2), but increasingly also to predict tumour control probability (TCP) and normal tissue complication probability (NTCP) using logistic models. The selection of accurate LQ parameters α, β and α/β is pivotal for a reliable estimate of radiation response. The aim of this review is to provide an overview of published values for the LQ parameters of human tumours as a guideline for radiation oncologists and radiation researchers to select appropriate radiobiological parameter values for LQ modelling in clinical radiotherapy. We performed a systematic literature search and found sixty-four clinical studies reporting α, β and α/β for tumours. Tumour site, histology, stage, number of patients, type of LQ model, radiation type, TCP model, clinical endpoint and radiobiological parameter estimates were extracted. Next, we stratified by tumour site and by tumour histology. Study heterogeneity was expressed by the I2 statistic, i.e. the percentage of variance in reported values not explained by chance. A large heterogeneity in LQ parameters was found within and between studies (I2 > 75%). For the same tumour site, differences in histology partially explain differences in the LQ parameters: epithelial tumours have higher α/β values than adenocarcinomas. For tumour sites with different histologies, such as in oesophageal cancer, the α/β estimates correlate well with histology. However, many other factors contribute to the study heterogeneity of LQ parameters, e.g. tumour stage, type of LQ model, TCP model and clinical endpoint (i.e. survival, tumour control and biochemical control). The value of LQ parameters for tumours as published in clinical radiotherapy studies depends on many clinical and methodological factors. Therefore, for clinical use of the LQ model, LQ parameters for tumour should be selected carefully, based on tumour site, histology and the applied LQ model. To account for uncertainties in LQ parameter estimates, exploring a range of values is recommended.

1 January 2020 in International Journal of Hyperthermia
Verified
Journal Article
Open access
H.P. KokH.P. Kok
H.P. Kok
ECErik N. K. Cressman
Erik N. K. Cressman
Wim CeelenWim Ceelen
Wim Ceelen
CBChristopher Brace
Christopher Brace
Robert IvkovRobert Ivkov
Robert Ivkov
Johannes Hans CrezeeJohannes Hans Crezee
Johannes Hans Crezee
The therapeutic application of heat is very effective in cancer treatment. Both hyperthermia, i.e., heating to 39–45 °C to induce sensitization to radiotherapy and chemotherapy, and thermal ablation, where temperatures beyond 50 °C destroy tumor cells directly are frequently applied in the clinic. Achievement of an effective treatment requires high quality heating equipment, precise thermal dosimetry, and adequate quality assurance. Several types of devices, antennas and heating or power delivery systems have been proposed and developed in recent decades. These vary considerably in technique, heating depth, ability to focus, and in the size of the heating focus. Clinically used heating techniques involve electromagnetic and ultrasonic heating, hyperthermic perfusion and conductive heating. Depending on clinical objectives and available technology, thermal therapies can be subdivided into three broad categories: local, locoregional, or whole body heating. Clinically used local heating techniques include interstitial hyperthermia and ablation, high intensity focused ultrasound (HIFU), scanned focused ultrasound (SFUS), electroporation, nanoparticle heating, intraluminal heating and superficial heating. Locoregional heating techniques include phased array systems, capacitive systems and isolated perfusion. Whole body techniques focus on prevention of heat loss supplemented with energy deposition in the body, e.g., by infrared radiation. This review presents an overview of clinical hyperthermia and ablation devices used for local, locoregional, and whole body therapy. Proven and experimental clinical applications of thermal ablation and hyperthermia are listed. Methods for temperature measurement and the role of treatment planning to control treatments are discussed briefly, as well as future perspectives for heating technology for the treatment of tumors. Graphical Abstract Schematic overview of clinically proven heating techniques used for various indications and tumor locations.

1 January 2009 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
PDF file
Johannes Hans CrezeeJohannes Hans Crezee
Johannes Hans Crezee
PHP.M.A. Van Haaren
P.M.A. Van Haaren
HWH. Westendorp
H. Westendorp
MGM. De Greef
M. De Greef
H.P. KokH.P. Kok
H.P. Kok
ABA. Bel
A. Bel
Background: The aim of this study is preclinical evaluation of our newly developed regional hyperthermia system providing 3-D SAR control: the AMC-8 phased array consisting of two rings, each with four 70 MHz waveguides. It was designed to achieve higher tumour temperatures and improve the clinical effectiveness of locoregional hyperthermia. Methods: The performance of the AMC-8 system was evaluated with simulations and measurements aiming at heating a centrally located target region in rectangular (30 × 30 × 110 cm) and elliptical (36 × 24 × 80 cm) homogeneous tissue equivalent phantoms. Three properties were evaluated and compared to its predecessor, the 2-D AMC-4 single ring four waveguide array: (1) spatial control and (2) size of the SAR focus, (3) the ratio between maximum SAR outside the target region and SAR in the focus. Distance and phase difference between the two rings were varied. Results: (1) Phase steering provides 3-D SAR control for the AMC-8 system. (2) The SAR focus is more elongated compared to the AMC-4 system, yielding a lower SAR level in the focus when using the same total power. This is counter-balanced by (3) a superficial SAR deposition which is half of that in the AMC-4 system, yielding a more favourable ratio between normal tissue and target SAR and allowing higher total power and up to 30% more SAR in the focus for 3 cm ring distance. Conclusion: The AMC-8 system is capable of 3-D SAR control and its SAR distribution is more favourable than for the 2-D AMC-4 system. This result promises improvement in clinical tumour temperatures.

1 January 2020 in Advanced Drug Delivery Reviews
Verified
Journal Article
Closed access
Arlene L. OeiArlene L. Oei
Arlene L. Oei
H.P. KokH.P. Kok
H.P. Kok
SOS.B. Oei
S.B. Oei
MHM.R. Horsman
M.R. Horsman
LSL.J.A. Stalpers
L.J.A. Stalpers
Johannes Hans CrezeeJohannes Hans Crezee
Johannes Hans Crezee

17 September 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
H.P. KokH.P. Kok
H.P. Kok
PWPeter Wust
Peter Wust
PSPaul R. Stauffer
Paul R. Stauffer
FBF Bardati
F Bardati
Gerard van RhoonGerard van Rhoon
Gerard van Rhoon
Johannes Hans CrezeeJohannes Hans Crezee
Johannes Hans Crezee
Locoregional hyperthermia, i.e. increasing the tumor temperature to 40–45 °C using an external heating device, is a very effective radio and chemosensitizer, which significantly improves clinical outcome. There is a clear thermal dose-effect relation, but the pursued optimal thermal dose of 43 °C for 1 h can often not be realized due to treatment limiting hot spots in normal tissue. Modern heating devices have a large number of independent antennas, which provides flexible power steering to optimize tumor heating and minimize hot spots, but manual selection of optimal settings is difficult. Treatment planning is a very valuable tool to improve locoregional heating. This paper reviews the developments in treatment planning software for tissue segmentation, electromagnetic field calculations, thermal modeling and optimization techniques. Over the last decade, simulation tools have become more advanced. On-line use has become possible by implementing algorithms on the graphical processing unit, which allows real-time computations. The number of applications using treatment planning is increasing rapidly and moving on from retrospective analyses towards assisting prospective clinical treatment strategies. Some clinically relevant applications will be discussed.

13 March 2013 in International Journal of Oncology
Verified
Journal Article
Closed access
NFNicolaas Franken
Nicolaas Franken
AOArlene L. Oei
Arlene L. Oei
H.P. KokH.P. Kok
H.P. Kok
HRHans M. Rodermond
Hans M. Rodermond
PSPeter Sminia
Peter Sminia
GBGerrit W. Barendsen
Gerrit W. Barendsen
Spandidos Publications is a scientific publisher with a long-standing international reputation for excellent standards and high quality science publications