Magnetically manipulated microrobots are demonstrated for targeted cell transportation. Full three‐dimensional (3D) porous structures are fabricated with an SU‐8 photoresist using a 3D laser lithography system. Nickel and titanium are deposited as a magnetic material and biocompatible material, respectively. The fabricated microrobots are controlled in the fluid by external magnetic fields. Human embryonic kidney 239 (HEK 239) cells are cultivated in the microrobot to show the possibility for targeted cell transportation.
Splinting techniques are widely used in medicine to inhibit the movement of arthritic joints. Studies into the effectiveness of splinting as a method of pain reduction have generally yielded positive results, however, no significant difference has been found in clinical outcomes between splinting types. Tactile sensing has shown great promise for the integration into splinting devices and may offer further information into applied forces to find the most effective methods of splinting. Hall effect-based tactile sensors are of particular interest in this application owing to their low-cost, small size, and high robustness. One complexity of the sensors is the relationship between the elastomer geometry and the measurement range. This paper investigates the design parameters of Hall effect tactile sensors for use in hand splinting. Finite element simulations are used to locate the areas in which sensitivity is high in order to optimise the deflection range of the sensor. Further simulations then investigate the mechanical response and force ranges of the elastomer layer under loading which are validated with experimental data. A 4 mm radius, 3 mm-thick sensor is identified as meeting defined sensing requirements for range and sensitivity. A prototype sensor is produced which exhibits a pressure range of 45 kPa normal and 6 kPa shear. A proof of principle prototype demonstrates how this can be integrated to form an instrumented splint with multi-axis sensing capability and has the potential to inform clinical practice for improved splinting.
22 March 2011 in Journal of Intelligent & Robotic Systems
Control of small magnetic machines in viscous fluids may enable new medical applications of microrobots. Small-scale viscous environments lead to low Reynolds numbers, and although the flow is linear and steady, the magnetic actuation introduces a dynamic response that is nonlinear. We account for these nonlinearities, and the uncertainties in the dynamic and magnetic properties of the microrobot, by using time-delay estimation. The microrobot consists of a cylindrical magnet, 1 mm long and 500 µm in diameter, and is tracked using a visual feedback system. The microrobot was placed in silicone oil with a dynamic viscosity of 1 Pa.s, and followed step inputs with rise times of 0.45 s, 0.51 s, and 1.77 s, and overshoots of 37.5%, 33.3%, and 34.4% in the x, y, and z directions, respectively. In silicone oil with a viscosity of 3 Pa.s, the rise times were 1.04 s, 0.72 s, and 2.19 s, and the overshoots were 47.8%, 48.5%, and 86.8%. This demonstrates that closed-loop control of the magnetic microrobot was better in the less viscous fluid.
14 February 2014 in Smart Materials and Structures