Diabetes is highly prevalent throughout the world and imposes a high economic cost on countries at all income levels. Foot ulceration is one devastating consequence of diabetes, which can lead to amputation and mortality. Clinical assessment of diabetic foot ulcer (DFU) is currently subjective and limited, impeding effective diagnosis, treatment and prevention. Studies have shown that pressure and shear stress at the plantar surface of the foot plays an important role in the development of DFUs. Quantification of these could provide an improved means of assessment of the risk of developing DFUs. However, commercially-available sensing technology can only measure plantar pressures, neglecting shear stresses and thus limiting their clinical utility. Research into new sensor systems which can measure both plantar pressure and shear stresses are thus critical. Our aim in this paper is to provide the reader with an overview of recent advances in plantar pressure and stress sensing and offer insights into future needs in this critical area of healthcare. Firstly, we use current clinical understanding as the basis to define requirements for wearable sensor systems capable of assessing DFU. Secondly, we review the fundamental sensing technologies employed in this field and investigate the capabilities of the resultant wearable systems, including both commercial and research-grade equipment. Finally, we discuss research trends, ongoing challenges and future opportunities for improved sensing technologies to monitor plantar loading in the diabetic foot.
Objective: This work aims to develop an integrated in-shoe measurement system to fully record plantar loading, including both pressure and shear stresses, across the full contact surface. These data are vital to help understand and prevent the development of complex conditions such as Diabetic Foot Ulcers (DFUs), a worldwide healthcare challenge. Currently no systems exist to reliably record these data. Methods: In this paper we report development of the SLIPS (‘Shear Load Inductive Plantar Sensing’) system which integrates 64 tri-axial force sensors into a flexible insole to measure plantar loading. SLIPS translates our multi-axis inductive load sensing technology into a full sensory array embedded within an insole and complete with communication and power bus. A pilot study evaluates the system in three healthy participants during walking. Results: Testing shows that the SLIPS system is well tolerated by participants and can operate under dynamic gait loading regimes. The pilot study reveals the complex nature of plantar loading. Regions of peak pressure loading align with anatomical landmarks and shear loading forms a significant component of the overall load. Notably, regions of peak shear and pressure are not necessarily collocated or present in unison. Conclusion: This work highlights the need for in-shoe plantar measurement systems like SLIPS capable of mapping both pressure and shear load, and their use to improve understanding of how these factors relate to clinical conditions like DFU. Significance: SLIPS represents the first in-shoe measurement system capable of measuring both pressure and shear across the whole plantar surface in unison.
Diabetic foot ulcers (DFUs) are a severe global public health issue. Plantar normal and shear load are believed to play an important role in the development of foot ulcers and could be a valuable indicator to improve assessment of DFUs. However, despite their promise, plantar load measurements currently have limited clinical application, primarily due to the lack of reliable measurement techniques particularly for shear load measurements. In this paper we report on the design and evaluation of a novel tri-axis force sensor to measure both normal and shear load on the foot’s plantar surface simultaneously. The sensor consists of a group of inductive sensing coils above which a conductive target is placed on a hyperelastic elastomer. Movement of the target under load affects the coil inductances which are measured and digitized by an embedded system. Using a computational finite element model, we investigated the influence of sensing coil form and configuration on sensor performance. A sensor configured with four-square coils and maximal turns provided the best performance for plantar load measurements. A prototype was fabricated and calibrated using a neural network to map the non-linear relationship between the sensor output and the applied tri-axis load. Experimental evaluation indicates that the tri-axis sensor can effectively detect shear load of ±16 N and normal load up to 105 N (RMS errors: 1.05 N and 1.73 N respectively) with a high performance. Overall, this sensor provides a promising basis for plantar normal and shear load measurement which are crucial for improved assessment of DFU.
Splinting techniques are widely used in medicine to inhibit the movement of arthritic joints. Studies into the effectiveness of splinting as a method of pain reduction have generally yielded positive results, however, no significant difference has been found in clinical outcomes between splinting types. Tactile sensing has shown great promise for the integration into splinting devices and may offer further information into applied forces to find the most effective methods of splinting. Hall effect-based tactile sensors are of particular interest in this application owing to their low-cost, small size, and high robustness. One complexity of the sensors is the relationship between the elastomer geometry and the measurement range. This paper investigates the design parameters of Hall effect tactile sensors for use in hand splinting. Finite element simulations are used to locate the areas in which sensitivity is high in order to optimise the deflection range of the sensor. Further simulations then investigate the mechanical response and force ranges of the elastomer layer under loading which are validated with experimental data. A 4 mm radius, 3 mm-thick sensor is identified as meeting defined sensing requirements for range and sensitivity. A prototype sensor is produced which exhibits a pressure range of 45 kPa normal and 6 kPa shear. A proof of principle prototype demonstrates how this can be integrated to form an instrumented splint with multi-axis sensing capability and has the potential to inform clinical practice for improved splinting.
The study of finger kinematics has developed into an important research area. Various hand tracking systems are currently available; however, they all have limited functionality. Generally, the most commonly adopted sensors are limited to measurements with one degree of freedom, i.e., flexion/extension of fingers. More advanced measurements including finger abduction, adduction, and circumduction are much more difficult to achieve. To overcome these limitations, we propose a two-axis 3D printed optical sensor with a compact configuration for tracking finger motion. Based on Malus’ law, this sensor detects the angular changes by analyzing the attenuation of light transmitted through polarizing film. The sensor consists of two orthogonal axes each containing two pathways. The two readings from each axis are fused using a weighted average approach, enabling a measurement range up to 180 and an improvement in sensitivity. The sensor demonstrates high accuracy (±0.3 ), high repeatability, and low hysteresis error. Attaching the sensor to the index finger’s metacarpophalangeal joint, real-time movements consisting of flexion/extension, abduction/adduction and circumduction have been successfully recorded. The proposed two-axis sensor has demonstrated its capability for measuring finger movements with two degrees of freedom and can be potentially used to monitor other types of body motion.
The limited grasping control available in Robot Assisted Surgery is considered a significant limitation of the technology. Traditionally the integration of haptic feedback has been proposed to resolve this issue but has found limited adoption. Here we investigate an alternate approach based on the concept of detecting localised slips caused by the intrinsic elastic properties of soft tissues. This method allows for the early detection of slip so that mitigating actions can be taken before gross slip can occur, allowing the grasper to minimise the force required to maintain stable grasp control. In this paper we detail the design of a sensor developed to detect incipient slip by monitoring the relative difference in tissue movement at the front and back of the grasper, caused by tissue slip. We then demonstrate the sensor’s efficacy for the early detection of slip, as well as its ability to automate grasping under representative surgical conditions, with the automated case providing comparable performance to one which uses the maximum allowable grasp force. This work provides evidence that the slip detection methodology developed is consistently able to detect incipient slip before macro slip occurs, thus offering a strong basis for its use in automating surgical grasping tasks to avoid tissue trauma and slip.