RENATO AMBROSIO

Prof. RENATO AMBROSIO

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
BLBernardo T Lopes
Bernardo T Lopes
IRIsaac C. Ramos
Isaac C. Ramos
MSMarcella Q. Salomão
Marcella Q. Salomão
FGFrederico P. Guerra
Frederico P. Guerra
SSSteve C. Schallhorn
Steve C. Schallhorn
RARENATO AMBROSIO
RENATO AMBROSIO

1 April 2013 in Revista Brasileira de Oftalmologia
Verified
Journal Article
Open access
PDF file
RARENATO AMBROSIO
RENATO AMBROSIO
IRIsaac Ramos
Isaac Ramos
ALAllan Luz
Allan Luz
FFFernando Correa Faria
Fernando Correa Faria
ASAndreas Steinmueller
Andreas Steinmueller
CRCynthia Jane Roberts
Cynthia Jane Roberts
OBJECTIVE: To describe a novel technique for clinical characterization of corneal biomechanics using non-invasive dynamic imaging. METHODS: Corneal deformation response during non contact tonometry (NCT) is monitored by ultra-high-speed (UHS) photography. The Oculus Corvis ST (Scheimpflug Technology; Wetzlar, Germany) has a UHS Scheimpflug camera, taking over 4,300 frames per second and of a single 8mm horizontal slit, for monitoring corneal deformation response to NCT. The metered collimated air pulse or puff has a symmetrical configuration and fixed maximal internal pump pressure of 25 kPa. The bidirectional movement of the cornea in response to the air puff is monitored. RESULTS: Measurement time is 30ms, with 140 frames acquired. Advanced algorithms for edge detection of the front and back corneal contours are applied for every frame. IOP is calculated based on the first applanation moment. Deformation amplitude (DA) is determined as the highest displacement of the apex in the highest concavity (HC) moment. Applanation length (AL) and corneal velocity (CVel) are recorded during ingoing and outgoing phases. CONCLUSION: Corneal deformation can be monitored during non contact tonometry. The parameters generated provide clinical in vivo characterization of corneal biomechanical properties in two dimensions, which is relevant for different applications in Ophthalmology

5 February 2020 in Eye and Vision
Verified
Journal Article
Open access
PDF file
LELouise Pellegrino Gomes Esporcatte
Louise Pellegrino Gomes Esporcatte
MSMarcella Q. Salomão
Marcella Q. Salomão
BLBernardo T. Lopes
Bernardo T. Lopes
PVPaolo Vinciguerra
Paolo Vinciguerra
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
RARENATO AMBROSIO
RENATO AMBROSIO
Corneal biomechanics has been a hot topic for research in contemporary ophthalmology due to its prospective applications in diagnosis, management, and treatment of several clinical conditions, including glaucoma, elective keratorefractive surgery, and different corneal diseases. The clinical biomechanical investigation has become of great importance in the setting of refractive surgery to identify patients at higher risk of developing iatrogenic ectasia after laser vision correction. This review discusses the latest developments in the detection of corneal ectatic diseases. These developments should be considered in conjunction with multimodal corneal and refractive imaging, including Placido-disk based corneal topography, Scheimpflug corneal tomography, anterior segment tomography, spectral-domain optical coherence tomography (SD-OCT), very-high-frequency ultrasound (VHF-US), ocular biometry, and ocular wavefront measurements. The ocular response analyzer (ORA) and the Corvis ST are non-contact tonometry systems that provide a clinical corneal biomechanical assessment. More recently, Brillouin optical microscopy has been demonstrated to provide in vivo biomechanical measurements. The integration of tomographic and biomechanical data into artificial intelligence techniques has demonstrated the ability to increase the accuracy to detect ectatic disease and characterize the inherent susceptibility for biomechanical failure and ectasia progression, which is a severe complication after laser vision correction.

19 December 2022 in American Journal of Ophthalmology
Verified
Journal Article
Open access
RARENATO AMBROSIO
RENATO AMBROSIO
AMAydano P. Machado
Aydano P. Machado
ELEdileuza Leão
Edileuza Leão
JLJoão Marcelo G. Lyra
João Marcelo G. Lyra
MSMarcella Q. Salomão
Marcella Q. Salomão
BLBernardo T. Lopes
Bernardo T. Lopes
To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection. Multicenter cross-sectional case-control retrospective study. A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations. The database included 1 eye randomly selected from 1680 normal patients (N) and from 1181 "bilateral" keratoconus (KC) patients, along with 551 normal topography eyes from patients with very asymmetric ectasia (VAE-NT), and their 474 unoperated ectatic (VAE-E) eyes. The current TBIv1 (tomographic-biomechanical index) was tested, and an optimized AI algorithm was developed for augmenting accuracy. The area under the receiver operating characteristic curve (AUC) of the TBIv1 for discriminating clinical ectasia (KC and VAE-E) was 0.999 (98.5% sensitivity; 98.6% specificity [cutoff: 0.5]), and for VAE-NT, 0.899 (76% sensitivity; 89.1% specificity [cutoff: 0.29]). A novel random forest algorithm (TBIv2), developed with 18 features in 156 trees using 10-fold cross-validation, had a significantly higher AUC (0.945; DeLong, P < .0001) for detecting VAE-NT (84.4% sensitivity and 90.1% specificity; cutoff: 0.43; DeLong, P < .0001) and a similar AUC for clinical ectasia (0.999; DeLong, P = .818; 98.7% sensitivity; 99.2% specificity [cutoff: 0.8]). Considering all cases, the TBIv2 had a higher AUC (0.985) than TBIv1 (0.974; DeLong, P < .0001). AI optimization to integrate Scheimpflug-based corneal tomography and biomechanical assessments augments accuracy for ectasia detection, characterizing ectasia susceptibility in the diverse VAE-NT group. Some patients with VAE may have true unilateral ectasia. Machine learning considering additional data, including epithelial thickness or other parameters from multimodal refractive imaging, will continuously enhance accuracy. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

1 July 2013 in Current Opinion in Ophthalmology
Verified
Journal Article
Closed access
RARENATO AMBROSIO
RENATO AMBROSIO
BVBruno F. Valbon
Bruno F. Valbon
FFFernando Faria-Correia
Fernando Faria-Correia
IRIsaac Ramos
Isaac Ramos
ALAllan Luz
Allan Luz
To review the principles and clinical applications of Scheimpflug corneal and anterior segment imaging with special relevance for laser refractive surgery. Computerized Scheimpflug imaging has been used for corneal and anterior segment tomography (CASTm) in different commercially available instruments. Such approach computes the three-dimensional image of the cornea and anterior segment, enabling the characterization of elevation and curvature of the front and back surfaces of the cornea, pachymetric mapping, calculation of the total corneal refractive power and anterior segment biometry. CASTm represents a major evolution for corneal and anterior segment analysis, beyond front surface corneal topography and single point central corneal thickness measurements. This approach enhances the diagnostic abilities for screening ectasia risk as well as for planning, evaluating the results, managing complications of refractive procedures, and selecting intraocular lens power, type, and design. In addition, dynamic Scheimpflug imaging has been recently introduced for in-vivo corneal biomechanical measurements and has also been used for anterior segment imaging of femtocataract surgery. Scheimpflug imaging has an important role for laser refractive surgery with different applications, which continuously improve due to advances in technology.

1 January 2019 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
JFJosé Ferreira-Mendes
José Ferreira-Mendes
BLBernardo T Lopes
Bernardo T Lopes
FFFernando Faria-Correia
Fernando Faria-Correia
MSMarcella Q. Salomão
Marcella Q. Salomão
SRSandra Rodrigues-Barros
Sandra Rodrigues-Barros
RARENATO AMBROSIO
RENATO AMBROSIO