Nowadays, patients with mild and moderate upper limb paralysis caused by cerebral apoplexy are uncomfortable with autonomous rehabilitation. In this paper, according to the “rope + toothed belt” generalized rope drive design scheme, we design a utility model for a wearable upper limb rehabilitation robot with a tension mechanism. Owing to study of the human upper extremity anatomy, movement mechanisms, and the ranges of motion, it can determine the range of motion angles of the human arm joints, and design the shoulder joint, elbow joint, and wrist joint separately under the principle of ensuring the minimum driving torque. Then, the kinematics, workspace and dynamics analysis of each structure are performed. Finally, the control system of the rehabilitation robot is designed. The experimental results show that the structure is convenient to wear on the human body, and the robot’s freedom of movement matches well with the freedom of movement of the human body. It can effectively support and traction the front and rear arms of the affected limb, and accurately transmit the applied traction force to the upper limb of the joints. The rationality of the wearable upper limb rehabilitation robot design is verified, which can help patients achieve rehabilitation training and provide an effective rehabilitation equipment for patients with hemiplegia caused by stroke.
29 August 2024 in Agricultural and Forest Meteorology
Due to insufficient muscle strength, a novel rehabilitation mechanism of the shoulder joint exoskeleton is proposed and analyzed based on gear and rack transmission, which solves the problem that stroke patients need repetitive exercise rehabilitation training. First, the range of motion angle of the shoulder joint is determined, and the mechanical structure of shoulder joint rehabilitation is designed. The arc rack is engaged with the output shaft gear of the reducer, and the servo motor is utilized as the driving force to realize the internal/external rotation movement of the shoulder joint. The motor connects the horizontal connecting rod and the rotating rod through the cross roller bearing to realize the abduction/adduction and flexion/extension movement of the shoulder joint. Second, the kinematics and dynamics of the shoulder joint exoskeleton are analyzed, investigated, and verified for the rehabilitation mechanism. The simulation analysis of the mechanism is completed in the virtual prototype. The changes in the joint angle and end trajectory and joint moment with time and angular velocity under the given working conditions are obtained, which directly reflect the movement of each joint of the rehabilitation mechanism. Finally, aiming at the nonlinear disturbance in the trajectory tracking control of the rehabilitation mechanism of the shoulder joint exoskeleton, the trajectory tracking approach of the mechanism is achieved aided with the closed-loop PD iterative learning control method. The results demonstrate that the actual trajectories are in good agreement with the desired trajectories, which can achieve effective tracking and improve the control quality of the system.
12 November 2020 in Applied Bionics and Biomechanics
This paper proposes a bionic flexible wrist parallel mechanism to simulate human wrist joints, which is characterized by a rope-driven, compression spring-supported hybrid mechanism. Specifically, to realize the movement of the wrist mechanism, a parallel structure is adopted to support the mobile platform and is controlled by a cable, which plays the role of wrist muscles. Because the compression spring is elastic, it is difficult to directly solve inverse kinematics. To address this problem, the external force acting on the moving platform is firstly equivalent to the vector force and torque at the center of the moving platform. Then, based on inverse kinematic and static analyses, the inverse motion of the robot model can be solved according to the force and torque balance conditions and the lateral spring bending equation of the compression spring. In order to verify the proposed method, kinematics, statics, and parallel mechanism workspace are further analyzed by the software MATLAB. The obtained results demonstrate the effectiveness and feasibility of the designed parallel mechanism. This work offers new insights into the parallel mechanism with flexible joints in replicating the movements of the human wrist, thus promoting the development of rehabilitation robots and rope-driven technology to some extent.
Instead of conventional proportional integral (PI) controller, non-linear fuzzy proportional integral (NLFPI) controller is proposed to control an inertially stabilized platform. The strategy is to start with a tuned, conventional PI controller that achieve a certain desired performance, replace it with an equivalent linear fuzzy proportional integral (LFPI) controller, and finally convert the linear fuzzy controller to nonlinear fuzzy controller. The system performance and robustness are investigated. Simulation results demonstrate the effectiveness of the designed controller, which offers an excellent performance and robustness in the presence of uncertainty and nonlinearity.
A new flexible contact structure using the principle of air pressure amplification is proposed to enable better access to information for the blind. First, the structure and working principle of piezoelectric flexible Braille contacts were designed and analyzed, and the theoretical model of air pressure amplification and theoretical expressions were established. Then the gas–solid coupling simulation analysis was carried out using COMSOL Multiphysics software to derive the influencing factors of the system flexible contact amplification and the degree of influence of different gases on the contact output displacement, and the structure of flexible Braille contacts was tested experimentally. The experimental results show that when the diameter of the air cavity is 24 mm, the height of the cavity is 6 mm, the thickness of the flexible film is 0.1 mm, the contact height is 2 mm, the input voltage is 135 V, the resonance frequency reaches 196.5 Hz, the maximum output displacement of the piezoelectric flexible Braille contact is 0.286 mm, and the point display effect of the Braille contact is more significant, which verifies the feasibility of the device.