Daniel Rosenkranz

Mr. Daniel Rosenkranz


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Analytica Chimica Acta
Verified
Journal Article
Closed access
DRDaniel Rosenkranz
Daniel Rosenkranz
FKFabian Kriegel
Fabian Kriegel
EMEmmanouil Mavrakis
Emmanouil Mavrakis
SPSpiros A. Pergantis
Spiros A. Pergantis
PRPhilipp Reichardt
Philipp Reichardt
ALAndreas Luch
Andreas Luch

22 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
YHYves Uwe Hachenberger
Yves Uwe Hachenberger
DRDaniel Rosenkranz
Daniel Rosenkranz
FKFabian Kriegel
Fabian Kriegel
BKBenjamin Krause
Benjamin Krause
RMRené Matschaß
René Matschaß
ALAndreas Luch
Andreas Luch
Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.

2 March 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YHYves Uwe Hachenberger
Yves Uwe Hachenberger
DRDaniel Rosenkranz
Daniel Rosenkranz
CKCharlotte Kromer
Charlotte Kromer
BKBenjamin Krause
Benjamin Krause
NDNadine Dreiack
Nadine Dreiack
ALAndreas Luch
Andreas Luch
A broad range of inorganic nanoparticles (NPs) and their dissolved ions possess a possible toxicological risk for human health and the environment. Reliable and robust measurements of dissolution effects may be influenced by the sample matrix, which challenges the analytical method of choice. In this study, CuO NPs were investigated in several dissolution experiments. Two analytical techniques (dynamic light scattering (DLS) and inductively-coupled plasma mass spectrometry (ICP-MS)) were used to characterize NPs (size distribution curves) time-dependently in different complex matrices (e.g., artificial lung lining fluids and cell culture media). The advantages and challenges of each analytical approach are evaluated and discussed. Additionally, a direct-injection single particle (DI sp)ICP-MS technique for assessing the size distribution curve of the dissolved particles was developed and evaluated. The DI technique provides a sensitive response even at low concentrations without any dilution of the complex sample matrix. These experiments were further enhanced with an automated data evaluation procedure to objectively distinguish between ionic and NP events. With this approach, a fast and reproducible determination of inorganic NPs and ionic backgrounds can be achieved. This study can serve as guidance when choosing the optimal analytical method for NP characterization and for the determination of the origin of an adverse effect in NP toxicity.

27 May 2025 in Journal of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
MMMartin Muehlbauer
Martin Muehlbauer
GBGunnar Brandhorst
Gunnar Brandhorst
DRDaniel Rosenkranz
Daniel Rosenkranz
KGKaren Friederike Gauß
Karen Friederike Gauß
APAstrid Petersmann
Astrid Petersmann
Objectives: Hemolysis in laboratory samples is a frequent error that may lead to clinical misinterpretation and incorrect patient treatment. Thus, modern laboratory analyzers are able to assess the hemolysis index (HI). To prevent reporting of erroneous results, manufacturers are obliged to provide reliable HI threshold values. The aim of this study was to proof the quality of manufacturer’s given HI thresholds. Methods: Dilution series with defined degrees of hemolysis were prepared by using blood samples from voluntary participants (n=77). In addition to the HI in each dilution, 18 measurands, namely sodium, potassium, chloride, aspartate aminotransferase (ASAT), alanine aminotransferase (ALAT), gamma-glutamyl transferase (GGT), lactate dehydrogenase (LDH), haptoglobin, total bilirubin, direct bilirubin, glutamate dehydrogenase (GLDH), creatine kinase (CK), iron, amylase, phosphate, total protein, enzymatic creatinine and high-sensitive troponin T, were measured on a cobas®pro analyzer. Thresholds for maximum deviation of measurement results of 5 , 10 and 20 % were calculated. Then we determined cut-offs as the 5th percentile and median. Results: Using potassium as an example we found HI thresholds at 57 (5th percentile) and 70 (median) with a corresponding result deviation of 5 % while the manufacturer HI threshold is given at 20. Thus, a higher HI threshold might be tolerated. Conclusions: We established HI thresholds for 18 biochemistry assays. Eight assays showed considerable deviations of which six may have potential clinical relevance like potassium and high-sensitive troponin T. Optimizing thresholds can help to reduce the risk of unnecessary blocking of results and preventing considerably impaired results from being released.

26 August 2024 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
YKYadwinder Kaur
Yadwinder Kaur
DRDaniel Rosenkranz
Daniel Rosenkranz
ABAnna Bloemer
Anna Bloemer
OAOzan Aykurt
Ozan Aykurt
GBGunnar Brandhorst
Gunnar Brandhorst
APAstrid Petersmann
Astrid Petersmann
Objectives: A recent challenge for clinical laboratories is the lack of clear guidelines for handling significant modifications of CE-marked assays. The modifications may involve, for example, extending measurement intervals, changing dilution procedures or using non-validated sample materials. The challenge arises due to the amended Regulation (EU) 2017/746 on in vitro diagnostic medical devices (IVDR), which is now poised for implementation, despite the extended transition periods. The IVDR application imposes challenges not only for diagnostic companies but also for clinical laboratories when using laboratory developed tests (LDTs), often referred to as in-house assays. In this context, a coherent and meticulously structured LDT documentation is highly beneficial. While laboratories are obliged to meet the IVDR requirements, the absence of a streamlined framework or guideline hampers the ability to gain a comprehensive overview on the requirements and possible options for their fulfilment. Methods: To address this issue, we introduce a web based digital tool powered by an R Shiny web application. This tool facilitates a seamless implementation of IVDR requirements for LDTs across diverse laboratory environments in terms of their transparency and validity. Our approach focuses on adequate handling of significant modifications of CE-marked in vitro diagnostic medical devices (IVD). Results: IVDRCheckR is an open-source tool that is easily accessible and free from system dependencies. The tool promotes a seamless process and a guide to enhance transparency, reliability, and validity of laboratory examination results based on LDTs. Additionally, the tool further provides modules for evaluating quality control data and quantitative method comparison data. Conclusions: Our Shiny web application-based platform is a digitised, user-friendly tool that simplifies the documentation for LDTs according to IVDR requirements with special emphasis on solutions for handling modifications to CE-marked assays.

24 September 2020 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
DRDaniel Rosenkranz
Daniel Rosenkranz
FKFabian L. Kriegel
Fabian L. Kriegel
EMEmmanouil Mavrakis
Emmanouil Mavrakis
SPSpiros A. Pergantis
Spiros A. Pergantis
PRPhilipp Reichardt
Philipp Reichardt
ALAndreas Luch
Andreas Luch
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration. Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet generator (µDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of µDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running. Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle. While mode I (counting) and mode III (µDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic standard solutions only. It is independent of NP reference materials. The µDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.