Yves Uwe Hachenberger

Mr. Yves Uwe Hachenberger

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Trends in Food Science & Technology
Verified
Journal Article
Closed access
APAprajita Tiwari Pandey
Aprajita Tiwari Pandey
IPIshan Pandey
Ishan Pandey
YHYves Uwe Hachenberger
Yves Uwe Hachenberger
BKBenjamin Krause
Benjamin Krause
RHRashad Haidar
Rashad Haidar
Ajay Vikram SinghAjay Vikram Singh
Ajay Vikram Singh

22 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
YHYves Uwe Hachenberger
Yves Uwe Hachenberger
DRDaniel Rosenkranz
Daniel Rosenkranz
FKFabian Kriegel
Fabian Kriegel
BKBenjamin Krause
Benjamin Krause
RMRené Matschaß
René Matschaß
ALAndreas Luch
Andreas Luch
Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.

2 March 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YHYves Uwe Hachenberger
Yves Uwe Hachenberger
DRDaniel Rosenkranz
Daniel Rosenkranz
CKCharlotte Kromer
Charlotte Kromer
BKBenjamin Krause
Benjamin Krause
NDNadine Dreiack
Nadine Dreiack
ALAndreas Luch
Andreas Luch
A broad range of inorganic nanoparticles (NPs) and their dissolved ions possess a possible toxicological risk for human health and the environment. Reliable and robust measurements of dissolution effects may be influenced by the sample matrix, which challenges the analytical method of choice. In this study, CuO NPs were investigated in several dissolution experiments. Two analytical techniques (dynamic light scattering (DLS) and inductively-coupled plasma mass spectrometry (ICP-MS)) were used to characterize NPs (size distribution curves) time-dependently in different complex matrices (e.g., artificial lung lining fluids and cell culture media). The advantages and challenges of each analytical approach are evaluated and discussed. Additionally, a direct-injection single particle (DI sp)ICP-MS technique for assessing the size distribution curve of the dissolved particles was developed and evaluated. The DI technique provides a sensitive response even at low concentrations without any dilution of the complex sample matrix. These experiments were further enhanced with an automated data evaluation procedure to objectively distinguish between ionic and NP events. With this approach, a fast and reproducible determination of inorganic NPs and ionic backgrounds can be achieved. This study can serve as guidance when choosing the optimal analytical method for NP characterization and for the determination of the origin of an adverse effect in NP toxicity.

1 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
RPRuud Peters
Ruud Peters
IEIngrid Elbers
Ingrid Elbers
AUAnna Undas
Anna Undas
ESEelco Sijtsma
Eelco Sijtsma
SBSophie Marie Briffa
Sophie Marie Briffa
Eugenia Valsami-JonesEugenia Valsami-Jones
Eugenia Valsami-Jones
ACEnano is an EU-funded project which aims at developing, optimising and validating methods for the detection and characterisation of nanomaterials (NMs) in increasingly complex matrices to improve confidence in the results and support their use in regulation. Within this project, several interlaboratory comparisons (ILCs) for the determination of particle size and concentration have been organised to benchmark existing analytical methods. In this paper the results of a number of these ILCs for the characterisation of NMs are presented and discussed. The results of the analyses of pristine well-defined particles such as 60 nm Au NMs in a simple aqueous suspension showed that laboratories are well capable of determining the sizes of these particles. The analysis of particles in complex matrices or formulations such as consumer products resulted in larger variations in particle sizes within technologies and clear differences in capability between techniques. Sunscreen lotion sample analysis by laboratories using spICP-MS and TEM/SEM identified and confirmed the TiO2 particles as being nanoscale and compliant with the EU definition of an NM for regulatory purposes. In a toothpaste sample orthogonal results by PTA, spICP-MS and TEM/SEM agreed and stated the TiO2 particles as not fitting the EU definition of an NM. In general, from the results of these ILCs we conclude that laboratories are well capable of determining particle sizes of NM, even in fairly complex formulations.

1 January 2022 in Current Medicinal Chemistry
Verified
Journal Article
Closed access
PDF file
FKFabian Kriegel
Fabian Kriegel
BKBenjamin Krause
Benjamin Krause
YHYves Uwe Hachenberger
Yves Uwe Hachenberger
RFRafael Fister
Rafael Fister
PRPhilipp Reichardt
Philipp Reichardt
ALAndreas Luch
Andreas Luch
: Compared to the classical chemicals, nanoparticles (NPs) exhibit unique properties, which lead to challenges in sample preparation and analysis. Fractionation techniques and, in particular, hollow fiber flow field flow fractionation (HF5) have recently become popular in the characterization and quantification of nanomaterials, because of their fine fractionation capability in the nanoscale-range. When dealing with NPs, a great drawback during fractionation is the loss of particles in the fractionation devices, tubing and connectors. There is a need for studies to systematically explore and assess the quality of the fractionation process. A combination of two complementary mass-based setups was used to determine particle loss in HF5. Inductively coupled plasma mass spectrometry (ICP-MS) enabled the estimation of recovery rates for NPs after HF5 separation. Reciprocally, laser ablation ICP-MS (LA-ICP-MS) permitted the evaluation of particles retained on the hollow fiber. 15 nm Au-NPs in different concentrations were evaluated in this study and showed a recovery level for Au-NPs of 50 – 65% based on the applied concentrations after a complete HF5 separation run. Detection of sample deposition on the hollow fiber by LA-ICP-MS indicated a sample loss of about 8%. These findings are important for experiments relying on fractionation of low concentrated nanoparticulate samples.

29 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
RPRuud Peters
Ruud Peters
IEIngrid Elbers
Ingrid Elbers
AUAnna Undas
Anna Undas
ESEelco Sijtsma
Eelco Sijtsma
SBSophie Marie Briffa
Sophie Marie Briffa
Eugenia Valsami-JonesEugenia Valsami-Jones
Eugenia Valsami-Jones
Due to miscommunication a number of potential co-authors were not listed in the original publication