Vasile Danut Cojocaru

Prof. Dr. Vasile Danut Cojocaru

Polytechnic University of Bucharest, Bucharest, Bucureşti, Romania
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2011 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DRD. Raducanu
D. Raducanu
EVE. Vasilescu
E. Vasilescu
VCVasile Danut Cojocaru
Vasile Danut Cojocaru
ICI. Cinca
I. Cinca
PDP. Drob
P. Drob
SDS.I. Drob
S.I. Drob

1 December 2013 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
VCVasile Danut Cojocaru
Vasile Danut Cojocaru
DRD. Raducanu
D. Raducanu
TGT. Gloriant
T. Gloriant
DGD.M. Gordin
D.M. Gordin
ICI. Cinca
I. Cinca

22 June 2017 in Materials
Verified
Journal Article
Open access
PDF file
PNPatricia Neacsu
Patricia Neacsu
ASAdela Ioana Staras
Adela Ioana Staras
Stefan Ioan VoicuStefan Ioan Voicu
Stefan Ioan Voicu
IIIuliana Ionascu
Iuliana Ionascu
TSTeodoru Soare
Teodoru Soare
Anisoara CimpeanAnisoara Cimpean
Anisoara Cimpean
Despite their good biocompatibility and adequate mechanical behavior, the main limitation of Mg alloys might be their high degradation rates in a physiological environment. In this study, a novel Mg-based alloy exhibiting an elastic modulus E = 42 GPa, Mg-1Ca-0.2Mn-0.6Zr, was synthesized and thermo-mechanically processed. In order to improve its performance as a temporary bone implant, a coating based on cellulose acetate (CA) was realized by using the dipping method. The formation of the polymer coating was demonstrated by FT-IR, XPS, SEM and corrosion behavior comparative analyses of both uncoated and CA-coated alloys. The potentiodynamic polarization test revealed that the CA coating significantly improved the corrosion resistance of the Mg alloy. Using a series of in vitro and in vivo experiments, the biocompatibility of both groups of biomaterials was assessed. In vitro experiments demonstrated that the media containing their extracts showed good cytocompatibility on MC3T3-E1 pre-osteoblasts in terms of cell adhesion and spreading, viability, proliferation and osteogenic differentiation. In vivo studies conducted in rats revealed that the intramedullary coated implant for fixation of femur fracture was more efficient in inducing bone regeneration than the uncoated one. In this manner, the present study suggests that the CA-coated Mg-based alloy holds promise for orthopedic aplications.


1 October 2007 in Journal of Non-Crystalline Solids
Verified
Journal Article
Closed access
FTF. Turquier
F. Turquier
VCVasile Danut Cojocaru
Vasile Danut Cojocaru
MSM. Stir
M. Stir
RNR. Nicula
R. Nicula
EBE. Burkel
E. Burkel

22 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
ANANNA NOCIVIN
ANNA NOCIVIN
DRDoina Rǎducanu
Doina Rǎducanu
Bogdan Stefan VasileBogdan Stefan Vasile
Bogdan Stefan Vasile
CTCorneliu Trisca-Rusu
Corneliu Trisca-Rusu
ECElisabeta Mirela Cojocaru
Elisabeta Mirela Cojocaru
VCVasile Danut Cojocaru
Vasile Danut Cojocaru
The present paper analyzed the microstructural characteristics and the mechanical properties of a Ti–Nb–Zr–Fe–O alloy of β-Ti type obtained by combining severe plastic deformation (SPD), for which the total reduction was of εtot = 90%, with two variants of super-transus solution treatment (ST). The objective was to obtain a low Young’s modulus with sufficient high strength in purpose to use the alloy as a biomaterial for orthopedic implants. The microstructure analysis was conducted through X-ray diffraction (XRD), scanning electron microscopy (SEM), and high-resolution transmission electron microscopy (HRTEM) investigations. The analyzed mechanical properties reveal promising values for yield strength (YS) and ultimate tensile strength (UTS) of about 770 and 1100 MPa, respectively, with a low value of Young’s modulus of about 48–49 GPa. The conclusion is that satisfactory mechanical properties for this type of alloy can be obtained if considering a proper combination of SPD + ST parameters and a suitable content of β-stabilizing alloying elements, especially the Zr/Nb ratio.