Yixuan Gao

Yixuan Gao

Auto-generated profile, based on publicly available information

Yixuan Gao

Computer Science, Cornell Tech, New york, New York, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
AAAlexander Travis Adams
Alexander Travis Adams
IMIlan Mandel
Ilan Mandel
YGYixuan Gao
Yixuan Gao
BHBryan W Heckman
Bryan W Heckman
RNRajalakshmi Nandakumar
Rajalakshmi Nandakumar
TCTanzeem Choudhury
Tanzeem Choudhury
Background: Many commodity pulse oximeters are insufficiently calibrated for patients with darker skin. We demonstrate a quantitative measurement of this disparity in peripheral blood oxygen saturation (SpO2) with a controlled experiment. To mitigate this, we present OptoBeat, an ultra–low-cost smartphone-based optical sensing system that captures SpO2 and heart rate while calibrating for differences in skin tone. Our sensing system can be constructed from commodity components and 3D-printed clips for approximately US $1. In our experiments, we demonstrate the efficacy of the OptoBeat system, which can measure SpO2 within 1% of the ground truth in levels as low as 75%. Objective: The objective of this work is to test the following hypotheses and implement an ultra–low-cost smartphone adapter to measure SpO2: skin tone has a significant effect on pulse oximeter measurements (hypothesis 1), images of skin tone can be used to calibrate pulse oximeter error (hypothesis 2), and SpO2 can be measured with a smartphone camera using the screen as a light source (hypothesis 3). Methods: Synthetic skin with the same optical properties as human skin was used in ex vivo experiments. A skin tone scale was placed in images for calibration and ground truth. To achieve a wide range of SpO2 for measurement, we reoxygenated sheep blood and pumped it through synthetic arteries. A custom optical system was connected from the smartphone screen (flashing red and blue) to the analyte and into the phone’s camera for measurement. Results: The 3 skin tones were accurately classified according to the Fitzpatrick scale as types 2, 3, and 5. Classification was performed using the Euclidean distance between the measured red, green, and blue values. Traditional pulse oximeter measurements (n=2000) showed significant differences between skin tones in both alternating current and direct current measurements using ANOVA (direct current: F2,5997=3.1170 × 105, P<.01; alternating current: F2,5997=8.07 × 106, P<.01). Continuous SpO2 measurements (n=400; 10-second samples, 67 minutes total) from 95% to 75% were captured using OptoBeat in an ex vivo experiment. The accuracy was measured to be within 1% of the ground truth via quadratic support vector machine regression and 10-fold cross-validation (R2=0.97, root mean square error=0.7, mean square error=0.49, and mean absolute error=0.5). In the human-participant proof-of-concept experiment (N=3; samples=3 × N, duration=20-30 seconds per sample), SpO2 measurements were accurate to within 0.5% of the ground truth, and pulse rate measurements were accurate to within 1.7% of the ground truth. Conclusions: In this work, we demonstrate that skin tone has a significant effect on SpO2 measurements and the design and evaluation of OptoBeat. The ultra-low-cost OptoBeat system enables smartphones to classify skin tone for calibration, reliably measure SpO2 as low as 75%, and normalize to avoid skin tone–based bias.

19 November 2025
Verified
Conference Paper
Open access
ZCZekun Chang
Zekun Chang
YGYixuan Gao
Yixuan Gao
YNYuta Noma
Yuta Noma
SFShuo Feng
Shuo Feng
XYXinyi Yang
Xinyi Yang
TRThijs Roumen
Thijs Roumen

26 February 2025
Verified
Conference Paper
Open access
YGYixuan Gao
Yixuan Gao
TATanvir Ahmed
Tanvir Ahmed
ZCZekun Chang
Zekun Chang
TRThijs Roumen
Thijs Roumen
RNRajalakshmi Nandakumar
Rajalakshmi Nandakumar
Wireless sensing technologies leveraging the acoustic and RF sensors in smart devices have advanced to enable accurate contactless monitoring of vital signs such as breathing and heartbeat. Wireless signal monitoring can enable important health applications, such as determining emotional states, detecting critical health conditions, and providing suitable interventions. While offering non-invasiveness and privacy advantages over wearables and cameras, these technologies pose serious privacy risks. The improved sensing accuracy allows any unauthorized sensor to detect sensitive health data without consent. This paper proposes VitalHide, a novel approach to protect vital signs from unauthorized sensing while still enabling wireless sensing for authorized devices. The key idea of VitalHide is to obfuscate the user's vital signs by generating a deceiving vital sign motion using a wearable mechanical device. The obfuscated signal can then only be decoded at authorized devices, while unauthorized devices receive deceiving vital signs. We show the feasibility of VitalHide by generating motion using a vibration sensor and shape memory alloy (SMA)-based smart textile, and the successful decoding of the obfuscated vital sign signal at the authorized receiver. This work advances privacy-preserving wireless sensing by securing personal health information against unauthorized access without affecting the utility of authorized devices.

13 November 2021 in JMIR Preprints
Verified
Preprint
Open access
AAAlexander Travis Adams
Alexander Travis Adams
IMIlan Mandel
Ilan Mandel
YGYixuan Gao
Yixuan Gao
BHBryan W Heckman
Bryan W Heckman
RNRajalakshmi Nandakumar
Rajalakshmi Nandakumar
TCTanzeem Choudhury
Tanzeem Choudhury
BACKGROUND Many commodity pulse oximeters are insufficiently calibrated for patients with darker skin. We demonstrate a quantitative measurement of this disparity in peripheral blood oxygen saturation (SpO2) with a controlled experiment. To mitigate this, we present OptoBeat, an ultra–low-cost smartphone-based optical sensing system that captures SpO2 and heart rate while calibrating for differences in skin tone. Our sensing system can be constructed from commodity components and 3D-printed clips for approximately US $1. In our experiments, we demonstrate the efficacy of the OptoBeat system, which can measure SpO2 within 1% of the ground truth in levels as low as 75%. OBJECTIVE The objective of this work is to test the following hypotheses and implement an ultra–low-cost smartphone adapter to measure SpO2: skin tone has a significant effect on pulse oximeter measurements (hypothesis 1), images of skin tone can be used to calibrate pulse oximeter error (hypothesis 2), and SpO2 can be measured with a smartphone camera using the screen as a light source (hypothesis 3). METHODS Synthetic skin with the same optical properties as human skin was used in ex vivo experiments. A skin tone scale was placed in images for calibration and ground truth. To achieve a wide range of SpO2 for measurement, we reoxygenated sheep blood and pumped it through synthetic arteries. A custom optical system was connected from the smartphone screen (flashing red and blue) to the analyte and into the phone’s camera for measurement. RESULTS The 3 skin tones were accurately classified according to the Fitzpatrick scale as types 2, 3, and 5. Classification was performed using the Euclidean distance between the measured red, green, and blue values. Traditional pulse oximeter measurements (n=2000) showed significant differences between skin tones in both alternating current and direct current measurements using ANOVA (direct current: F2,5997=3.1170 × 105, P<.01; alternating current: F2,5997=8.07 × 106, P<.01). Continuous SpO2 measurements (n=400; 10-second samples, 67 minutes total) from 95% to 75% were captured using OptoBeat in an ex vivo experiment. The accuracy was measured to be within 1% of the ground truth via quadratic support vector machine regression and 10-fold cross-validation (R2=0.97, root mean square error=0.7, mean square error=0.49, and mean absolute error=0.5). In the human-participant proof-of-concept experiment (N=3; samples=3 × N, duration=20-30 seconds per sample), SpO2 measurements were accurate to within 0.5% of the ground truth, and pulse rate measurements were accurate to within 1.7% of the ground truth. CONCLUSIONS In this work, we demonstrate that skin tone has a significant effect on SpO2 measurements and the design and evaluation of OptoBeat. The ultra-low-cost OptoBeat system enables smartphones to classify skin tone for calibration, reliably measure SpO2 as low as 75%, and normalize to avoid skin tone–based bias.


26 October 2026
Verified
Conference Paper
Open access
TATanvir Ahmed
Tanvir Ahmed
YGYixuan Gao
Yixuan Gao
AAAdnan Armouti
Adnan Armouti
RNRajalakshmi Nandakumar
Rajalakshmi Nandakumar