Lotta Hamari

Dr. Lotta Hamari

University of Turku, Finland
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
KGKirsi Grym
Kirsi Grym
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
EEEeva Ekholm
Eeva Ekholm
LHLotta Hamari
Lotta Hamari
IAIman Azimi
Iman Azimi
AAAnna Axelin
Anna Axelin
Smart wristbands enable the continuous monitoring of health parameters, for example, in maternity care. Understanding the feasibility and acceptability of these devices in an authentic context is essential. The aim of this study was to evaluate the feasibility of using a smart wristband to collect continuous activity, sleep and heart rate data from the beginning of the second trimester until one month postpartum. The feasibility of a smart wristband was tested prospectively through pregnancy in nulliparous women (n = 20). The outcomes measured were the wear time of the device and the participants’ experiences with the smart wristband. The data were collected from the wristbands, phone interviews, questionnaires, and electronic patient records. The quantitative data were analyzed with hierarchical linear mixed models for repeated measures, and qualitative data were analyzed using content analysis. Participants (n = 20) were recruited at a median of 12.9 weeks of gestation. They used the smart wristbands for an average of 182 days during the seven-month study period. The daily use of the devices was similar during the second (17.9 h, 95% CI 15.2 to 20.7) and third trimesters (16.7 h, 95% CI 13.8 to 19.5) but decreased during the postpartum period (14.4 h, 95% CI 11.4 to 17.4, p = 0.0079). Participants who could not wear smart wristbands at work used the device 300 min less per day than did those with no use limitations. Eight of the participants did not wear the devices or wore them only occasionally after giving birth. Nineteen participants reported that the smart wristband did not have any permanent effects on their behavior. Problems with charging and synchronizing the devices, perceiving the devices as uncomfortable, or viewing the data as unreliable, and the fear of scratching their babies with the devices were the main reasons for not using the smart wristbands. A smart wristband is a feasible tool for continuous monitoring during pregnancy. However, the daily use decreased after birth. The results of this study may support the planning of future studies and help with overcoming barriers related to the use of smart wristbands on pregnant women.

20 April 2017 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
LHLotta Hamari
Lotta Hamari
TKTiina Kullberg
Tiina Kullberg
JRJukka Ruohonen
Jukka Ruohonen
OHOlli Heinonen
Olli Heinonen
Natalia Diaz RodriguezNatalia Diaz Rodriguez
Natalia Diaz Rodriguez
SSSanna Salanterä
Sanna Salanterä
Self-quantification of health parameters is becoming more popular; thus, the validity of the devices requires assessments. The aim of this study was to evaluate the validity of Fitbit One step counts (Fitbit Inc., San Francisco, CA, USA) against Actigraph wActisleep-BT step counts (ActiGraph, LLC, Pensacola, FL, USA) for measuring habitual physical activity among children. The study was implemented as a cross-sectional experimental design in which participants carried two waist-worn activity monitors for five consecutive days. The participants were chosen with a purposive sampling from three fourth grade classes (9–10 year olds) in two comprehensive schools. Altogether, there were 34 participants in the study. From these, eight participants were excluded from the analysis due to erroneous data. Primary outcome measures for step counts were Fitbit One and Actigraph wActisleep-BT. The supporting outcome measures were based on activity diaries and initial information sheets. Classical Bland–Altman plots were used for reporting the results. The average per-participant daily difference between the step counts from the two devices was 1937. The range was [116, 5052]. Fitbit One gave higher step counts for all but the least active participant. According to a Bland–Altman plot, the hourly step counts had a relative large mean bias across participants (161 step counts). The differences were partially explained by activity intensity: higher intensity denoted higher differences, and light intensity denoted lower differences. Fitbit One step counts are comparable to Actigraph step counts in a sample of 9–10-year-old children engaged in habitual physical activity in sedentary and light physical activity intensities. However, in moderate-to-vigorous physical activity, Fitbit One gives higher step counts when compared to Actigraph.

24 July 2020 in JMIR Formative Research
Verified
Journal Article
Open access
JSJohanna Saarikko
Johanna Saarikko
HNHannakaisa Niela-Vilen
Hannakaisa Niela-Vilen
EEEeva Ekholm
Eeva Ekholm
LHLotta Hamari
Lotta Hamari
IAIman Azimi
Iman Azimi
AAAnna Axelin
Anna Axelin
Background: Monitoring during pregnancy is vital to ensure the mother’s and infant’s health. Remote continuous monitoring provides health care professionals with significant opportunities to observe health-related parameters in their patients and to detect any pathological signs at an early stage of pregnancy, and may thus partially replace traditional appointments. Objective: This study aimed to evaluate the feasibility of continuously monitoring the health parameters (physical activity, sleep, and heart rate) of nulliparous women throughout pregnancy and until 1 month postpartum, with a smart wristband and an Internet of Things (IoT)–based monitoring system. Methods: This prospective observational feasibility study used a convenience sample of 20 nulliparous women from the Hospital District of Southwest Finland. Continuous monitoring of physical activity/step counts, sleep, and heart rate was performed with a smart wristband for 24 hours a day, 7 days a week over 7 months (6 months during pregnancy and 1 month postpartum). The smart wristband was connected to a cloud server. The total number of possible monitoring days during pregnancy weeks 13 to 42 was 203 days and 28 days in the postpartum period. Results: Valid physical activity data were available for a median of 144 (range 13-188) days (75% of possible monitoring days), and valid sleep data were available for a median of 137 (range 0-184) days (72% of possible monitoring days) per participant during pregnancy. During the postpartum period, a median of 15 (range 0-25) days (54% of possible monitoring days) of valid physical activity data and 16 (range 0-27) days (57% of possible monitoring days) of valid sleep data were available. Physical activity decreased from the second trimester to the third trimester by a mean of 1793 (95% CI 1039-2548) steps per day (P<.001). The decrease continued by a mean of 1339 (95% CI 474-2205) steps to the postpartum period (P=.004). Sleep during pregnancy also decreased from the second trimester to the third trimester by a mean of 20 minutes (95% CI –0.7 to 42 minutes; P=.06) and sleep time shortened an additional 1 hour (95% CI 39 minutes to 1.5 hours) after delivery (P<.001). The mean resting heart rate increased toward the third trimester and returned to the early pregnancy level during the postpartum period. Conclusions: The smart wristband with IoT technology was a feasible system for collecting representative data on continuous variables of health parameters during pregnancy. Continuous monitoring provides real-time information between scheduled appointments and thus may help target and tailor pregnancy follow-up.

26 March 2021 in Journal of Immigrant and Minority Health
Verified
Journal Article
Open access
PDF file
LHLotta Hamari
Lotta Hamari
JKJenni Konttila
Jenni Konttila
MMMarko Merikukka
Marko Merikukka
ATAnna-Maria Tuomikoski
Anna-Maria Tuomikoski
PKPetra Kouvonen
Petra Kouvonen
MKMarjo Kurki
Marjo Kurki
Parental support is of paramount importance in the promotion of positive parenting, strengthening parenthood and protecting children from disadvantages due to immigration experiences. The aim was to describe what is known about parent support programmes targeted to families who are immigrants. Electronic databases and the grey literature were systematically and comprehensively searched with no time/language restrictions. JBI approach and PRISMA-ScR were used to guide the review. N = 88 articles were sourced. Interventions were targeted to improve parental practices, skills and family wellbeing, usually through group-based methods. Most interventions included components of positive parenting and family communication. Identifying the needs of the target group and cultural tailoring were reported to be highly important in gaining acceptability, promoting engagement and producing benefits. Parent support programmes for families who are immigrants potentially improve positive parental practices and families’ wellbeing. There are many applicable and effective interventions to be exploited.

29 November 2019 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
LHLotta Hamari
Lotta Hamari
LJLiisa S. Järvelä
Liisa S. Järvelä
PLPäivi M. Lähteenmäki
Päivi M. Lähteenmäki
MAMikko Arola
Mikko Arola
AAAnna Axelin
Anna Axelin
SSSanna Salanterä
Sanna Salanterä
Objective: To evaluate the effect of active video games in promoting physical activity and motor performance, and reducing fatigue in children with cancer. A randomized controlled trial was conducted. The intervention included playing Nintendo Wii™Fit (Nintendo Co., Ltd., Kyoto, Japan) for 30 min/day for 8 weeks. Physical activity was estimated with accelerometers, physical activity diaries and questionnaires. Movement-ABC2 and PedsQL™ were used to examine motor performance and fatigue. Intervention experiences and fidelity were examined with an interview.Results: Participants (n = 36 children with cancer, 3–16 years-old) were randomly assigned to the intervention and control groups. The median [min–max] accelerometer counts/h (500 [131–1130] vs 385 [116–1012], p = 0.63) and physical activity min/day (34 [0–150] vs 23 [0–260], p = 0.95) did not differ between the groups. Change between the pre-test and post-test regarding motor performance and fatigue was similar in both groups (motor performance p = 0.77; fatigue p = 1.00). Participants experienced playing active video games meaningful, but the intervention was not followed completely as instructed. Overall, the physical activity levels were low and one fourth of the children had or were at risk of having movement difficulties.Trial registration: ClinicalTrials.gov identifier: NCT01748058 (October 15, 2012)

20 January 2021 in Current Oncology
Verified
Journal Article
Open access
PDF file
AWAmanda Wurz
Amanda Wurz
EMEmma McLaughlin
Emma McLaughlin
CVCarolina Chamorro Chamorro Vina
Carolina Chamorro Chamorro Vina
SGSarah L. Grimshaw
Sarah L. Grimshaw
LHLotta Hamari
Lotta Hamari
S.Nicole Culos-ReedS.Nicole Culos-Reed
S.Nicole Culos-Reed
The field of pediatric exercise oncology explores the relationships between physical activity (PA), including exercise, and a range of outcomes among children and adolescents affected by cancer. Although PA is safe and beneficial for this population, several important gaps in knowledge and practice remain. In this article, we describe research and innovation needs that were developed with a team of international experts and relevant literature, a series of online surveys, and an in-person meeting. Addressing these needs will contribute valuable knowledge and practice outputs to advance this field, ultimately enabling a greater number of children and adolescents affected by cancer to realize the benefits of moving more.