Alagar R. Muthukumar

Dr. Alagar R. Muthukumar

Department of Pathology, university of Texas Southwestern Medical Center, Dallas, TX, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2021 in Circulation
Verified
Journal Article
Closed access
PDF file
CRCarolyn M. Rosner
Carolyn M. Rosner
LGLeonard Genovese
Leonard Genovese
BTBehnam N. Tehrani
Behnam N. Tehrani
MAMelany Atkins
Melany Atkins
HBHooman Bakhshi
Hooman Bakhshi
CDChristopher R. Defilippi
Christopher R. Defilippi
Supplemental Digital Content is available in the text.

10 August 2021 in Circulation
Verified
Journal Article
Closed access
PDF file
AMAlagar R. Muthukumar
Alagar R. Muthukumar
MNMadhusudhanan Narasimhan
Madhusudhanan Narasimhan
QLQuan-Zhen Li
Quan-Zhen Li
LMLenin Mahimainathan
Lenin Mahimainathan
IHImran Hitto
Imran Hitto
JLJames A. de Lemos
James A. de Lemos
Supplemental Digital Content is available in the text.

18 June 2021 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
PDF file
MNMadhusudhanan Narasimhan
Madhusudhanan Narasimhan
LMLenin Mahimainathan
Lenin Mahimainathan
EAEllen Araj
Ellen Araj
ACAndrew E. Clark
Andrew E. Clark
JMJohn Markantonis
John Markantonis
AMAlagar R. Muthukumar
Alagar R. Muthukumar
The COVID-19 pandemic continues to impose a significant burden on global health infrastructure. While identification and containment of new cases remains important, laboratories must now pivot and consider an assessment of SARS-CoV-2 immunity in the setting of the recent availability of multiple COVID-19 vaccines. Here we have utilized the latest Abbott Alinity semi-quantitative IgM and quantitative IgG spike protein (SP) serology assays (IgMSP and IgGSP) in combination with Abbott Alinity IgG nucleocapsid (NC) antibody test (IgGNC) to assess antibody responses in a cohort of 1236 unique participants comprised of naïve, SARS-CoV-2 infected, and vaccinated (including both naïve and recovered) individuals. The IgMSP and IgGSP assays were highly specific (100%) with no cross-reactivity to archived samples collected prior to the emergence of SARS-CoV-2, including those from individuals with seasonal coronavirus infections. Clinical sensitivity was 96% after 15 days for both IgMSP and IgGSP assays individually. When considered together, the sensitivity was 100%. A combination of NC- and SP-specific serologic assays clearly differentiated naïve, SARS-CoV-2-infected, and vaccine-related immune responses. Vaccination resulted in a significant increase in IgGSP and IgMSP values, with a major rise in IgGSP following the booster (second) dose in the naïve group. In contrast, SARS-CoV-2 recovered individuals had several fold higher IgGSP responses than naïve following the primary dose, with a comparatively dampened response following the booster. This work illustrates the strong clinical performance of these new serological assays and their utility in evaluating and distinguishing serological responses to infection and vaccination.

15 July 2020 in American Journal of Clinical Pathology
Verified
Journal Article
Open access
PDF file
WPWilliam S Phipps
William S Phipps
JSJeffrey SoRelle
Jeffrey SoRelle
QLQuan-Zhen Li
Quan-Zhen Li
LMLenin Mahimainathan
Lenin Mahimainathan
EAEllen Araj
Ellen Araj
AMAlagar R. Muthukumar
Alagar R. Muthukumar
Objectives: Initial reports indicate adequate performance of some serology-based severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) assays. However, additional studies are required to facilitate interpretation of results, including how antibody levels impact immunity and disease course. Methods: A total of 967 subjects were tested for IgG antibodies reactive to SARS-CoV-2, including 172 suspected cases of SARS-CoV-2, 656 plasma samples from healthy donors, 49 sera from patients with rheumatic disease, and 90 specimens from individuals positive for polymerase chain reaction (PCR)–based respiratory viral panel. A subgroup of SARS-CoV-2 PCR-positive cases was tested for IgM antibodies by proteome array method. Results: All specificity and cross-reactivity specimens were negative for SARS-CoV-2 IgG antibodies (0/795, 0%). Positive agreement of IgG with PCR was 83% of samples confirmed to be more than 14 days from symptom onset, with less than 100% sensitivity attributable to a case with severe immunosuppression. Virus-specific IgM was positive in a higher proportion of cases less than 3 days from symptom onset. No association was observed between mild and severe disease course with respect to IgG and IgM levels. Conclusions: The studied SARS-CoV-2 IgG assay had 100% specificity and no adverse cross-reactivity. Measures of IgG and IgM antibodies did not predict disease severity in our patient population.

30 June 2021 in Vaccines
Verified
Journal Article
Open access
PDF file
MNMadhusudhanan Narasimhan
Madhusudhanan Narasimhan
LMLenin Mahimainathan
Lenin Mahimainathan
ACAndrew Clark
Andrew Clark
AUAmena Usmani
Amena Usmani
JCJing Cao
Jing Cao
AMAlagar R. Muthukumar
Alagar R. Muthukumar
Background: Lung-transplant (LT) recipients are at high risk for COVID-19 due to immunosuppression and respiratory tropism of SARS-CoV-2. The information on the effect of COVID-19 mRNA vaccines to elicit immunogenic responses after a two-dose (2D) regimen in LT recipients is sparse. Thus, we assessed the effect of Pfizer-BioNTech and Moderna mRNA vaccines’ 2D regimen on anti-spike responses in immunocompromised LT recipients. Methods: We utilized serum samples from LT recipients vaccinated for SARS-CoV-2 with 2D of either the Pfizer-BioNTech or Moderna vaccines and 2D-vaccinated naïve (non-transplanted and non-exposed to COVID-19) group. Antibody responses were assessed using the FDA-approved SARS-CoV-2 anti-nucleocapsid protein IgG assay (IgGNC), the SARS-CoV-2 anti-spike protein IgM assay (IgMSP), and the SARS-CoV-2 anti-spike protein IgG II assay (IgGSP). CD4+ T-cell activity was assessed as a marker of immune competence using the ImmuKnow® assay. Results: About 25% (18/73) of SARS-CoV-2 uninfected-LT patients generated a positive spike-IgG response following 2D of vaccines, with 36% (9/25) in the Moderna cohort and only 19% (9/48) in the Pfizer cohort. 2D in LT patients elicited a significantly lesser median IgGSP response (1.7 AU/mL, 95% CI: 0.6–7.5 AU/mL) compared to non-transplanted, uninfected naïve subjects (14,209 AU/mL, 95% CI: 11,261–18,836 AU/mL; p < 0.0001). In LT patients, the Moderna-evoked seropositivity trend was higher than Pfizer. Conclusion: 2D COVID-19 vaccination elicits a dampened serological response in LT patients. Whether assessing other arms of host immunity combined with a higher vaccine dose can better capture and elicit improved immunogenicity in this immunocompromised population warrants investigation.

25 May 2022 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
ACAndrew E Clark
Andrew E Clark
ZWZhaohui Wang
Zhaohui Wang
EOEmily Ostman
Emily Ostman
HZHui Zheng
Hui Zheng
HYHuiyu Yao
Huiyu Yao
JSJeffrey SoRelle
Jeffrey SoRelle
Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants continue to emerge, and effective tracking requires rapid return of results. Surveillance of variants is typically performed by whole genome sequencing (WGS), which can be financially prohibitive and requires specialized equipment and bioinformatic expertise. Genotyping approaches are rapid methods for monitoring SARS-CoV-2 variants but require continuous adaptation. Fragment analysis may represent an approach for improved SARS-CoV-2 variant detection. Methods: A multiplex fragment analysis approach (CoVarScan) was validated using PCR targeting variants by size and fluorescent color. Eight SARS-CoV-2 mutational hot spots in variants of concern (VOCs) were targeted. Three primer pairs (recurrently deleted region [RDR] 1, RDR2, and RDR3–4) flank RDRs in the S-gene. Three allele-specific primers target recurrent spike receptor binding domain mutants. Lastly, 2 primer pairs target recurrent deletions or insertions in ORF1A and ORF8. Fragments were resolved and analyzed by capillary electrophoresis (ABI 3730XL), and mutational signatures were compared to WGS results. Results: We validated CoVarScan using 3544 clinical respiratory specimens. The assay exhibited 96% sensitivity and 99% specificity compared to WGS. The limit of detection for the core targets (RDR1, RDR2, and ORF1A) was 5 copies/reaction. Variants were identified in 95% of samples with cycle threshold (CT) <30 and 75% of samples with a CT 34 to 35. Assay design was frozen April 2021, but all subsequent VOCs have been detected including Delta (n = 2820), Mu, (n = 6), Lambda (n = 6), and Omicron (n = 309). Genotyping results are available in as little as 4 h. Conclusions: Multiplex fragment analysis is adaptable and rapid and has similar accuracy to WGS to classify SARS-CoV-2 variants.