Jing Cao

Dr. Jing Cao

University of Texas Southwestern Medical Center
orcid
Associate Professor at the University of Texas Southwestern ...

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2021 in Vaccines
Verified
Journal Article
Open access
PDF file
MNMadhusudhanan Narasimhan
Madhusudhanan Narasimhan
LMLenin Mahimainathan
Lenin Mahimainathan
ACAndrew Clark
Andrew Clark
AUAmena Usmani
Amena Usmani
JCJing Cao
Jing Cao
AMAlagar R. Muthukumar
Alagar R. Muthukumar
Background: Lung-transplant (LT) recipients are at high risk for COVID-19 due to immunosuppression and respiratory tropism of SARS-CoV-2. The information on the effect of COVID-19 mRNA vaccines to elicit immunogenic responses after a two-dose (2D) regimen in LT recipients is sparse. Thus, we assessed the effect of Pfizer-BioNTech and Moderna mRNA vaccines’ 2D regimen on anti-spike responses in immunocompromised LT recipients. Methods: We utilized serum samples from LT recipients vaccinated for SARS-CoV-2 with 2D of either the Pfizer-BioNTech or Moderna vaccines and 2D-vaccinated naïve (non-transplanted and non-exposed to COVID-19) group. Antibody responses were assessed using the FDA-approved SARS-CoV-2 anti-nucleocapsid protein IgG assay (IgGNC), the SARS-CoV-2 anti-spike protein IgM assay (IgMSP), and the SARS-CoV-2 anti-spike protein IgG II assay (IgGSP). CD4+ T-cell activity was assessed as a marker of immune competence using the ImmuKnow® assay. Results: About 25% (18/73) of SARS-CoV-2 uninfected-LT patients generated a positive spike-IgG response following 2D of vaccines, with 36% (9/25) in the Moderna cohort and only 19% (9/48) in the Pfizer cohort. 2D in LT patients elicited a significantly lesser median IgGSP response (1.7 AU/mL, 95% CI: 0.6–7.5 AU/mL) compared to non-transplanted, uninfected naïve subjects (14,209 AU/mL, 95% CI: 11,261–18,836 AU/mL; p < 0.0001). In LT patients, the Moderna-evoked seropositivity trend was higher than Pfizer. Conclusion: 2D COVID-19 vaccination elicits a dampened serological response in LT patients. Whether assessing other arms of host immunity combined with a higher vaccine dose can better capture and elicit improved immunogenicity in this immunocompromised population warrants investigation.

1 March 2018 in Journal of Clinical Lipidology
Verified
Journal Article
Closed access
JCJing Cao
Jing Cao
BSBrian T. Steffen
Brian T. Steffen
WGWeihua Guan
Weihua Guan
ARAlan T. Remaley
Alan T. Remaley
JMJoseph P. McConnell
Joseph P. McConnell
MTMichael Y. Tsai
Michael Y. Tsai

3 September 2024 in The Journal of Applied Laboratory Medicine
Verified
Journal Article
Open access
PDF file
JCJing Cao
Jing Cao
LDLeslie Donato
Leslie Donato
JEJoe M El-Khoury
Joe M El-Khoury
AGAnne Goldberg
Anne Goldberg
JMJeffrey W Meeusen
Jeffrey W Meeusen
ARAlan T Remaley
Alan T Remaley
Background: The accurate measurement of blood lipids and lipoproteins is crucial for the clinical management of atherosclerotic disease risk. Despite progress in standardization, there are still significant variations in pre-analytical requirements, methods, nomenclature, and reporting work flows. Content: The guidance document aims to improve standardization of clinical lipid testing work flows. It provides recommendations for the components of the lipid panel, fasting requirements, reporting of results, and specific recommendations for non-high-density lipoprotein cholesterol (non-HDL-C), low-density lipoprotein cholesterol (LDL-C), lipoprotein(a) [Lp(a)], apolipoprotein B (apo B), point-of-care lipid testing, and LDL subfraction testing. Summary: Lipid panels should always report non-HDL-C and LDL-C calculations if possible. Fasting is not routinely required except in specific cases. Modern equations should be utilized for LDL-C calculation. These equations allow for LDL-C reporting at elevated concentrations of triglycerides and obviate the need for direct measured LDL-C in most cases.

1 December 2017 in Practical Laboratory Medicine
Verified
Journal Article
Open access
JCJing Cao
Jing Cao
RERachel Edwards
Rachel Edwards
JCJanette Chairez
Janette Chairez
SDSridevi Devaraj
Sridevi Devaraj
Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

3 September 2025 in Clinical Chemistry
Verified
Journal Article
Closed access
JMJeffrey W Meeusen
Jeffrey W Meeusen
XYXin Yi
Xin Yi
SCSteven W Cotten
Steven W Cotten
JNJacob B Nielsen
Jacob B Nielsen
LDLeslie J Donato
Leslie J Donato
JCJing Cao
Jing Cao
Background: Direct measurement of low-density lipoprotein cholesterol (LDL-C) is widely used and recommended by professional society guidelines despite its potential limitations in patients with hypertriglyceridemia and low LDL-C. This study evaluated the performance of 3 direct LDL-C (LDL-CD) assays, 2 modern LDL-C calculation methods [LDL-C Martin (LDL-CM), LDL-C modified Sampson (LDL-CS)] and the conventional Friedewald (LDL-CF) method against the reference method, beta-quantification (LDL-CBQ). Methods: A total of 181 remnant sera from patients with standard lipid panel orders or from patients with LDL-CBQ orders with triglycerides (TG) ≥ 400 mg/dL (4.5 mmol/L), or with TG ≥ 150 mg/dL (1.69 mmol/L) and LDL-C < 70 mg/dL (1.8 mmol/L) were included. LDL-CD and lipid panel data were gathered from Abbott Alinity, Roche Cobas, and Siemens Atellica platforms. Results: LDL-CD among the 3 platforms showed a median CV of 11.2%. In patients with TG <400 mg/dL, LDL-CM and LDL-CS demonstrated less bias and less misclassification at the clinical decision LDL-C levels than LDL-CF or LDL-CD. In the 400 to 800 mg/dL (9.0 mmol/L) TG group, LDL-CS was superior to LDL-CD or LDL-CM in accuracy. When TG is ≥ 800 mg/dL, LDL-CD (Roche) showed substantial bias from LDL-CBQ while LDL-CS (Roche) showed smaller but significant bias. Conclusions: In summary, LDL-CD or LDL-CF showed little advantage over the 2 modern LDL-C calculation methods. LDL-CS showed the best overall correlation with LDL-CBQ and therefore is recommended to replace LDL-CF and potentially LDL-CD when making clinical decisions in patients with low LDL-C and hypertriglyceridemia.

1 June 2021 in Atherosclerosis
Verified
Journal Article
Closed access
JCJing Cao
Jing Cao
ARAlan T. Remaley
Alan T. Remaley
WGWeihua Guan
Weihua Guan
SDSridevi Devaraj
Sridevi Devaraj
MTMichael Y. Tsai
Michael Y. Tsai