Erica Leoni

Prof. Erica Leoni

Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna 40126, Italy
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2004 in Journal of Applied Microbiology
Verified
Journal Article
Open access
PDF file
ELErica Leoni
Erica Leoni
GLG. De Luca
G. De Luca
PLP.P. Legnani
P.P. Legnani
RSR. Sacchetti
R. Sacchetti
SSS. Stampi
S. Stampi
FZF. Zanetti
F. Zanetti
Aims: An evaluation was made of the prevalence of Legionella species in hot water distribution systems in the city of Bologna (Italy) and their possible association with bacterial contamination (total counts and Pseudomonadaceae) and the chemical characteristics of the water (pH, Ca, Mg, Fe, Mn, Cu, Zn and Total Organic Carbon, TOC). Methods and Results: A total of 137 hot water samples were analysed: 59 from the same number of private apartments, 46 from 11 hotels and 32 from five hospitals, all using the same water supply. Legionella species were detected in 40·0% of the distribution systems, L. pneumophila in 33·3%. The highest colonization was found in the hot water systems of hospitals (93·7% of samples positive for L. pneumophila, geometric mean: 2·4 × 103 CFU l−1), followed by the hotels (60·9%, geometric mean: 127·3 CFU l−1) and the apartments with centralized heating (41·9%, geometric mean: 30·5 CFU l−1). The apartments with independent heating systems showed a lower level of colonization (3·6% for Legionella species), with no evidence of L. pneumophila. Correlation analysis suggests that copper exerts an inhibiting action, while the TOC tends to favour the development of L. pneumophila. No statistically significant association was seen with Pseudomonadaceae, which were found at lower water temperatures than legionellae and in individual distribution points rather than in the whole network. Conclusions: The water recirculation system used by centralized boilers enhances the spreading of legionellae throughout the whole network, both in terms of the number of colonized sites and in terms of CFU count. Significance and Impact of the Study: Differences in Legionella colonization between types of buildings are not due to a variation in water supply but to other factors. Besides the importance of water recirculation, the study demonstrates the inhibiting action of copper and the favourable action of TOC on the development of L. pneumophila.

19 November 2018 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
TSTiziana Sanna
Tiziana Sanna
Laura DallolioLaura Dallolio
Laura Dallolio
ARAlessandra Raggi
Alessandra Raggi
MMMagda Mazzetti
Magda Mazzetti
GLGiovanni Lorusso
Giovanni Lorusso
ELErica Leoni
Erica Leoni
Environmental cleaning practice plays an important role in reducing microbial contamination in hospital surfaces and contributes to prevent Healthcare Associated Infections. Adenosine Triphosphate (ATP) bioluminescence assay is a commonly used method for assessing environmental cleanliness on healthcare surfaces. This study tested the feasibility of using ATP-bioluminescence assay for evaluating the efficiency of cleaning procedures in the operating theatre settings, comparing the ATP-bioluminescence test with the traditional culture method. The surfaces of 10 operating rooms of two public hospitals (140 samples in total) were examined “at rest”, in two moments of the same daily session: before the first scheduled operation (Pre), and before the second, after a clean environment was re-established (Post). Surface contamination was assessed using the cultural method to detect Total Viable Counts (TVC36°C) and ATP-bioluminescence assay (RLU). The examined surfaces presented very low TVCs (geometric means: 1.8 CFU/plate; IC95%: 1.6–2.0), always compliant with the relative reference standards. No statistical correlation was found between ATP values and TVCs. However, considering the results in terms of general evaluation of hygienic quality of surfaces, the two methods were consistent in identifying the most contaminated areas (Hospital A > Hospital B; Pre > Post; most contaminated surfaces: scialytic lamp). Furthermore, the ATP mean values showed a progressive increase from surfaces with TVC = 0 to surfaces with TVC > 15 CFU/plate. Although not an alternative to cultural methods, the ATP-bioluminescence-assay can be a useful tool to measure the efficiency of cleaning procedures also in environments with very low microbial counts. Each health facility should identify appropriate reference values, depending on the devices used and on the basis of the analysis of the data collected through spatial and temporal sampling series. By providing a rapid feedback, the ATP-assay helps to increase the awareness of operators and allows immediate action to be taken in critical situations.

ELErica Leoni
Erica Leoni
FCFederica Catalani
Federica Catalani
Sofia MariniSofia Marini
Sofia Marini
Laura DallolioLaura Dallolio
Laura Dallolio
Legionella spp. is widespread in many natural and artificial water systems, such as hot water distribution networks, cooling towers, and spas. A particular risk factor has been identified in the use of whirlpools and hot tubs in spa facilities and public baths. However, there has been no systematic synthesis of the published literature reporting legionellosis cases or outbreaks related to swimming/spa pools or similar environments used for recreational purposes (hot springs, hot tubs, whirlpools, natural spas). This study presents the results of a systematic review of the literature on cases and outbreaks associated with these environments. Data were extracted from 47 articles, including 42 events (17 sporadic cases and 25 outbreaks) and 1079 cases, 57.5% of which were diagnosed as Pontiac fever, without any deaths, and 42.5% were of Legionnaires’ disease, with a fatality rate of 6.3%. The results are presented in relation to the distribution of Legionella species involved in the events, clinical manifestations and diagnosis, predisposing conditions in the patients, favourable environmental factors, and quality of the epidemiological investigation, as well as in relation to the different types of recreational water sources involved. Based on the epidemiological and microbiological criteria, the strength of evidence linking a case/outbreak of legionellosis with a recreational water system was classified as strong, probable, and possible; in more than half of the events the resulting association was strong.

23 July 2013 in Journal of School Health
Verified
Journal Article
Closed access
PDF file
Rossella SacchettiRossella Sacchetti
Rossella Sacchetti
ACAndrea Ceciliani
Andrea Ceciliani
AGAndrea Garulli
Andrea Garulli
Laura DallolioLaura Dallolio
Laura Dallolio
PBPatrizia Beltrami
Patrizia Beltrami
ELErica Leoni
Erica Leoni

Laura DallolioLaura Dallolio
Laura Dallolio
ASAmalia Scuderi
Amalia Scuderi
MRMaria S. Rini
Maria S. Rini
SABRINA VALENTESABRINA VALENTE
SABRINA VALENTE
PFpatrizia farruggia
patrizia farruggia
ELErica Leoni
Erica Leoni
Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

Laura DallolioLaura Dallolio
Laura Dallolio
ARAlessandra Raggi
Alessandra Raggi
TSTiziana Sanna
Tiziana Sanna
MMMagda Mazzetti
Magda Mazzetti
AOAlessandra Orsi
Alessandra Orsi
ELErica Leoni
Erica Leoni
The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols.