Environmental cleaning practice plays an important role in reducing microbial contamination in hospital surfaces and contributes to prevent Healthcare Associated Infections. Adenosine Triphosphate (ATP) bioluminescence assay is a commonly used method for assessing environmental cleanliness on healthcare surfaces. This study tested the feasibility of using ATP-bioluminescence assay for evaluating the efficiency of cleaning procedures in the operating theatre settings, comparing the ATP-bioluminescence test with the traditional culture method. The surfaces of 10 operating rooms of two public hospitals (140 samples in total) were examined “at rest”, in two moments of the same daily session: before the first scheduled operation (Pre), and before the second, after a clean environment was re-established (Post). Surface contamination was assessed using the cultural method to detect Total Viable Counts (TVC36°C) and ATP-bioluminescence assay (RLU). The examined surfaces presented very low TVCs (geometric means: 1.8 CFU/plate; IC95%: 1.6–2.0), always compliant with the relative reference standards. No statistical correlation was found between ATP values and TVCs. However, considering the results in terms of general evaluation of hygienic quality of surfaces, the two methods were consistent in identifying the most contaminated areas (Hospital A > Hospital B; Pre > Post; most contaminated surfaces: scialytic lamp). Furthermore, the ATP mean values showed a progressive increase from surfaces with TVC = 0 to surfaces with TVC > 15 CFU/plate. Although not an alternative to cultural methods, the ATP-bioluminescence-assay can be a useful tool to measure the efficiency of cleaning procedures also in environments with very low microbial counts. Each health facility should identify appropriate reference values, depending on the devices used and on the basis of the analysis of the data collected through spatial and temporal sampling series. By providing a rapid feedback, the ATP-assay helps to increase the awareness of operators and allows immediate action to be taken in critical situations.
Some laboratory investigations are abnormal during the course of Crohn's disease (CD). We investigated the trend of some of these laboratory tests in a group of patients with CD to study the relationships between an activity index made up of such laboratory parameters only (LCDAI) and the usual Crohn's disease activity index (CDAI). One hundred thirty-one examinations of 63 patients were evaluated. At each investigation, besides calculation of the CDAI, 10 laboratory investigations were carried out. Three gastroenterologists independently gave an overall evaluation of the laboratory activity for each of the 131 examinations on the basis of the results of the blood tests alone. The sum of the evaluations was used as an independent variable on which a laboratory index was developed by multiple regression analysis. C reactive protein, red cell sedimentation rate, acid alpha 1-glycoprotein, alpha 1-antitrypsin, and white blood cells had an important share in the development of this laboratory index. The evaluation of the relationships existing between LCDAI and CDAI showed that in patients with moderate to severe clinical disease activity, LCDAI was constantly altered. The same happened in 55% of cases in clinical remission, which suggests an inflammatory activity that is not clinically evident. These results point to the advisability of supplementing a predominantly clinical index, such as CDAI, with a laboratory index such as LCDAI in the evaluation of CD.
1 September 2013 in International Journal of Infectious Diseases
Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.