Zuomin Zhao

Dr. Zuomin Zhao

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2014 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
PMPetro Moilanen
Petro Moilanen
ZZZuomin Zhao
Zuomin Zhao
PKPasi Karppinen
Pasi Karppinen
TKTimo Karppinen
Timo Karppinen
VKVantte Kilappa
Vantte Kilappa
JTJussi Timonen
Jussi Timonen

24 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PKpriya karthikeyan
priya karthikeyan
SMsadegh moradi
sadegh moradi
HFHany Ferdinando
Hany Ferdinando
ZZZuomin Zhao
Zuomin Zhao
TMTeemu Myllylä
Teemu Myllylä
Functional near-infrared spectroscopy (fNIRS) has been utilized already around three decades for monitoring the brain, in particular, oxygenation changes in the cerebral cortex. In addition, other optical techniques are currently developed for in vivo imaging and in the near future can be potentially used more in human brain research. This paper reviews the most common label-free optical technologies exploited in brain monitoring and their current and potential clinical applications. Label-free tissue monitoring techniques do not require the addition of dyes or molecular contrast agents. The following optical techniques are considered: fNIRS, diffuse correlations spectroscopy (DCS), photoacoustic imaging (PAI) and optical coherence tomography (OCT). Furthermore, wearable optical brain monitoring with the most common applications is discussed.

20 August 2004 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
EAErkki Alarousu
Erkki Alarousu
JHJukka T Hast
Jukka T Hast
MKMatti Kinnunen
Matti Kinnunen
Mikhail KirillinMikhail Kirillin
Mikhail Kirillin
RMRisto Myllyla
Risto Myllyla
ZZZuomin Zhao
Zuomin Zhao
In this paper, optical measurement techniques, which enable non-invasive measurement, are superimposed to glucose sensing in scattering media. Used measurement techniques are Optical Coherence Tomography (OCT), Photoacoustic spectroscopy (PAS) and laser pulse Time-of-Flight (TOF) measurement using a streak camera. In parallel with measurements, a Monte-Carlo (MC) simulation models have been developed. Experimental in vitro measurements were performed using Intralipid fat emulsion as a tissue simulating phantom for OCT and TOF measurements. In PAS measurements, a pork meat was used as a subject but also preliminary in vivo measurements were done. OCT measurement results show that the slope of the OCT signal's envelope changes as a function of glucose content in the scattering media. TOF measurements show that the laser pulse full width of half maximum (FWHM) changes a little as function of glucose content. An agreement with MC-simulations and measurements with Intralipid was also found. Measurement results of PAS technique show that changes in glucose content in the pork meat tissue can be measured. In vivo measurements with a human volunteer show that other factors such as physiological change, blood circulation and body temperature drift may interfere the PA response of glucose.

25 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MOMohammadreza Omidali
Mohammadreza Omidali
AMAli Mardanshahi
Ali Mardanshahi
Mariella SärestöniemiMariella Särestöniemi
Mariella Särestöniemi
ZZZuomin Zhao
Zuomin Zhao
TMTeemu Myllylä
Teemu Myllylä
Development of acousto−optic (AO) techniques has made progress in recent years across a range of medical application fields, especially in improving resolution, detection speed, and imaging depth. This paper presents a comprehensive overview of recent advancements in AO−based techniques that have been presented after the previously published review in 2017. The survey covers a description of theoretical modeling strategies and numerical simulation methods as well as recent applications in medical fields. It also provides a comparison between different techniques in terms of complexity, achieved depth in tissue, and resolution. In addition, a comparison between different numerical simulation methods will be outlined. Additionally, a number of challenges faced by AO techniques are considered, particularly in the context of realistic in vivo imaging. Finally, the paper discusses prospects of AO−based medical diagnosis methods.

10 October 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
PMPetro Moilanen
Petro Moilanen
ASAri Salmi
Ari Salmi
VKVantte Kilappa
Vantte Kilappa
ZZZuomin Zhao
Zuomin Zhao
JTJussi Timonen
Jussi Timonen
EHEdward Hæggström
Edward Hæggström
This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2–3 mm wall thickness) embraced by an opaque soft-tissue mimicking elastomer coating (5 mm thick). A predetermined time delay matching the selected mode and frequency was employed between the outputs of the elements. The generated ultrasound was detected by a 215 kHz piezo receiver. Our results suggest that this array reduces the disturbances caused by the elastomer cover and so pave way to permit non-contacting in vivo guided wave ultrasound assessment of human bones. The implementation is small, inexpensive, and robust in comparison with the conventional pulsed lasers.

20 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZZZuomin Zhao
Zuomin Zhao
TMTeemu Myllylä
Teemu Myllylä
For combining optical and ultrasonic imaging methodologies, photoacoustic imaging (PAI) is the most important and successful hybrid technique, which has greatly contributed to biomedical research and applications. Its theoretical background is based on the photoacoustic effect, whereby a modulated or pulsed light is emitted into tissue, which selectively absorbs the optical energy of the light at optical wavelengths. This energy produces a fast thermal expansion in the illuminated tissue, generating pressure waves (or photoacoustic waves) that can be detected by ultrasonic transducers. Research has shown that optical absorption spectroscopy offers high optical sensitivity and contrast for ingredient determination, for example, while ultrasound has demonstrated good spatial resolution in biomedical imaging. Photoacoustic imaging combines these advantages, i.e., high contrast through optical absorption and high spatial resolution due to the low scattering of ultrasound in tissue. In this review, we focus on advances made in PAI in the last five years and present categories and key devices used in PAI techniques. In particular, we highlight the continuously increasing imaging depth achieved by PAI, particularly when using exogenous reagents. Finally, we discuss the potential of combining PAI with other imaging techniques.