Petro Moilanen

Petro Moilanen

Auto-generated profile, based on publicly available information

Petro Moilanen

Altum Technologies, Helsinki, Finland

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2009 in Clinical Rehabilitation
Verified
Journal Article
Closed access
AZA. Zheng
A. Zheng
RSR. Sakari
R. Sakari
SCSm Cheng
Sm Cheng
AHA. Hietikko
A. Hietikko
PMP. Moilanen
P. Moilanen
MAM. Alèn
M. Alèn
Objective: To evaluate the effects of a low-frequency sound wave therapy programme on functional capacity, blood circulation and bone metabolism of the frail elderly. Design: Single-blind, randomized, controlled trial. Setting: Two senior service centres. Subjects: Forty-nine volunteers (14 males and 35 females) aged 62—93 years with up to 12 diagnosed diseases were allocated in either the intervention group (n = 30) or control group (n = 19). Intervention: The intervention group underwent sound wave therapy, 3—5 times a week for 30 minutes per session over a period of 6 months. The control group received no intervention. Main measurements: Blood pressure, functional capacity, mobility, bone density, biochemical markers, isometric muscle strength, balance, and skin surface temperature. Results: Compared with the control group, the intervention group’s mobility and the amount of self-reported kilometres walked per week increased by 3 km (P<0.05), while levels of cholesterol (4.97 (0.72) to 4.52 (0.65) mmol/L, P =0.019), low-density lipoprotein (2.82 (0.72) to 2.45 (0.61) mmol/L, P =0.022), bone markers of total osteocalcin (11.0 (6.5) to 10.3 (5.9) ng/mL, P =0.048)) and tartrate-resistant acid phosphatase isoform 5b (2.50 (1.0) to 2.41 (1.1) IU/L, P =0.021)) decreased. The average skin surface temperature was significantly higher during active sessions at the end of the intervention than in the beginning (P = 0.004). No change was found during placebo sessions. Conclusions: Low-frequency sound wave therapy may have the potential to promote well-being of frail elderly subjects via improved functional capacity, especially in subjects who are too frail to undertake exercise.

10 October 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
PMPetro Moilanen
Petro Moilanen
ASAri Salmi
Ari Salmi
VKVantte Kilappa
Vantte Kilappa
ZZZuomin Zhao
Zuomin Zhao
JTJussi Timonen
Jussi Timonen
EHEdward Hæggström
Edward Hæggström
This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2–3 mm wall thickness) embraced by an opaque soft-tissue mimicking elastomer coating (5 mm thick). A predetermined time delay matching the selected mode and frequency was employed between the outputs of the elements. The generated ultrasound was detected by a 215 kHz piezo receiver. Our results suggest that this array reduces the disturbances caused by the elastomer cover and so pave way to permit non-contacting in vivo guided wave ultrasound assessment of human bones. The implementation is small, inexpensive, and robust in comparison with the conventional pulsed lasers.

1 October 2019
Verified
Conference Paper
Closed access
OTOskari Tommiska
Oskari Tommiska
PMPetro Moilanen
Petro Moilanen
JMJoonas Mustonen
Joonas Mustonen
TRTimo Rauhala
Timo Rauhala
MGMaria Gritsevich
Maria Gritsevich
EHEdward Haggstrom
Edward Haggstrom
Time reversal (TR) is a technique based on the reciprocity principle of the wave equation that can be used to focus waves. In an enclosed system, comprising homogenous medium that includes no reflecting targets, it normally is impossible to use time reversal to focus ultrasound into the medium. Our proposed solution to this problem is to use simulations to produce signals that are subsequently time reversed and used for focusing. We show that one can model the forward propagation with finite-element method (FEM), then time-reverse it, and finally transmit it back to generate a time reversed focus in an experimental setup. The results show that accurate TR focusing can be achieved using simulated signals both in homogenous media and in media including distinct inclusions.

26 June 2023 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
PMP. Moilanen
P. Moilanen
TRT. Rauhala
T. Rauhala
SAS. Ahmadzai
S. Ahmadzai

1 October 2019
Verified
Conference Paper
Closed access
JMJoonas Mustonen
Joonas Mustonen
OTOskari Tommiska
Oskari Tommiska
TRTimo Rauhala
Timo Rauhala
PMPetro Moilanen
Petro Moilanen
MGMaria Gritsevich
Maria Gritsevich
EHEdward Haggstrom
Edward Haggstrom
Time-reversal (TR) is method to focus acoustic energy inside complex media. TR focusing to a predefined target point requires either an echo from a target point with acoustic impedance contrast or direct impulse actuation at the target point. Here, we used FEM to simulate the direct impulse actuation and focused ultrasound successfully to different locations in homogenous media with only four narrowband Langevin transducers. Measured intensities indicate that the focal point of the acoustic field was translated and the pressure scan shows that our TR technique works both in simulation and in experimental domain.