Yingjie He

Prof. Yingjie He

Department of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YCYuxi Cai
Yuxi Cai
YHYingjie He
Yingjie He
HZHongwei Zhou
Hongwei Zhou
JLJinjun Liu
Jinjun Liu
The trial and error method is the conventional method for LCL parameter design. Its efficiency is low and it is difficult to obtain the optimal parameter. Furthermore, due to the lack of detailed analysis of the high-frequency harmonics in the inverter output voltage, the designed LCL filter cannot effectively filter them, resulting that the quality of the grid-connected current cannot fully meet IEEE 519 standard. Based on the above-mentioned problems, the high-frequency harmonics of inverter output voltage is analyzed in detail in this article, and the multiobjective optimization function, including five optimization objectives, is constructed. Combined with the particle swarm optimization, a screening method is proposed to realize the multiobjective optimization process. Under the proposed method, the LCL parameter, which happens to meet the requirement of IEEE 519 for the high-frequency harmonic distortion rate of the grid-connected current, can be obtained, and the greatest tradeoff of LCL filtering performance and filter cost is achieved. In addition, the proposed method considers the problem of weak grid and provides a complete engineering solution for LCL parameter design in different degrees of weak grid. Finally, the effectiveness and accuracy of the proposed design method are verified by contrast simulation and experiment.

18 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YCYuxi Cai
Yuxi Cai
YHYingjie He
Yingjie He
HZHongwei Zhou
Hongwei Zhou
JLJinjun Liu
Jinjun Liu
In the medium- and high-power grid-connected photovoltaic system, the controller bandwidth is constrained due to the low switching frequency. This issue limits the resonant frequency of the traditional proportional multiresonant (PMR) controller, and then makes it difficult to suppress the main lowfrequency harmonics in the grid-connected current. In addition, it is difficult for PMR to maintain good performance under the severe operating conditions, such as the grid voltage containing the resonant-frequency harmonic, the grid voltage sagging etc. Based on the above practical problems and on-site requirements, a novel first-order active-disturbance-rejection active-damping control strategy, based on the inverter-side current feedback (ICF-ADRC-AD) for LCL grid-connected inverter is proposed in this paper. The standard form of the system block diagram is deduced, the stability and immunity of the system are analyzed. Finally, the effectiveness and superiority of the proposed control strategy under different operating conditions are verified by simulation and experiment. The control strategy proposed in this paper improves the suppression effect of low-frequency total harmonic and resonance, and also improves the stability and immunity of the system.

31 January 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YCYuxi Cai
Yuxi Cai
YHYingjie He
Yingjie He
HZHaixiao Zhang
Haixiao Zhang
HZHongwei Zhou
Hongwei Zhou
JLJinjun Liu
Jinjun Liu
In high-power grid-connected inverter for new energy power generation system, low switching frequency makes the control loop, LCL -filter resonant peak, and sideband harmonics generated by modulation coupled so that the parameter design of filter and controller affects each other. This increases the difficulty of design of filter parameters and controller parameters. To solve this problem, the accurate current harmonic calculation method based on the harmonic state-space model and considering switching frequency and control delay is proposed in this article first. Second, based on the above model, the parameter optimization process considering current harmonic distortion rate, filter cost, and so on is constructed. The integrated optimization design of filter and controller parameters of low-switching-frequency LCL grid-connected inverter is completed through intelligent algorithm. Thus, the filter cost is minimized on the premise that inverter performances meet the specific requirements. In addition, considering the nonideal characteristic of grid, a scheme of integrated parameter design that can adapt to the large-scale change of grid strength is proposed. Finally, the effectiveness of the proposed method and scheme is verified by simulation and experiment.

20 August 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JQJilang Qiu
Jilang Qiu
YHYingjie He
Yingjie He
CLChao Lei
Chao Lei
QJQianming Jiao
Qianming Jiao
JLJinjun Liu
Jinjun Liu
Transformerless three-level inverters have many advantages over two-level inverters in photovoltaic (PV) systems. However, in transformerless systems, except for the inherent unbalanced neutral voltage of the three-level inverter, the leakage current also needs to be limited strictly. Concerning the defects of the conventional common-mode voltage (CMV) suppression methods, an improved LMSVM (ILMSVM) method is proposed. Unlike the conventional CMV suppression method, the ILMSVM method no longer just abandons the high CMV small vectors to limit the range of CMV to ±1/ $6U_{\mathrm {dc}}$ , but limits CMV variation to $\Delta 1/6U_{\mathrm {dc}}$ in all switching cycles. So, high CMV small vectors also can be used in some sequence to help controlling neutral point (NP) while keeping leakage current well suppressed. Moreover, medium vector sequences are also used as an independent control sequence to help achieving bidirectional control on NP potential. Compared with LMP/NSVM strategy, the ILMSVM method has advantages in regulating NP potential, and leakage current spikes of the LMP/NSVM method are also eliminated. In comparison with the conventional SVPWM (CSVPWM) method, leakage current in the ILMSVM method is also well restrained. Simulations and experiment results verify that the ILMSVM method can well restrain leakage current and maintain good control of NP in comparing with LMP/space vector modulation (SVM) method and CSVPWM method.

25 August 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YCYuxi Cai
Yuxi Cai
YHYingjie He
Yingjie He
HZHaixiao Zhang
Haixiao Zhang
HZHongwei Zhou
Hongwei Zhou
JLJinjun Liu
Jinjun Liu
Under low-switching-frequency condition, there is harmonic coupling in grid-connected inverter. The harmonic state-space (HSS) modeling method is an effective means to analyze the output harmonic characteristics of inverter. When the switching frequency is low, the sampling/holding and control delay make the update of pulsewidth modulation pulses more untimely, which will have a non-negligible impact on system output. However, the current relevant research fails to take these factors into account in the HSS model. In addition, the existing work fails to thoroughly study the calculation and analysis methods of HSS model, and the relevant work is insufficient. Based on this, this article studies the closed-loop HSS model and its calculation and analysis methods of three-level grid-connected inverter considering the digitization impact. First, according to the different calculation and analysis methods of the HSS model of the grid-connected inverter, the methods considering the digitization impact are proposed, respectively. Second, according to the proposed method, the harmonic characteristics of low-switching-frequency grid-connected inverter are analyzed, and the necessity of considering the digitization impact is explained. Finally, the effectiveness and accuracy of the proposed HSS-model calculation and analysis methods considering the digitization impact are verified by simulation and experiment.

4 June 2020 in IEEE Access
Verified
Journal Article
Open access
YHYingjie He
Yingjie He
YLYunfeng Liu
Yunfeng Liu
CLChao Lei
Chao Lei
JLJinjun Liu
Jinjun Liu
The carrier-based PWM method (CBPWM) and the space vector PWM method (SVPWM) are two main modulation methods for diode clamped multilevel converters, and there is a certain relationship between these two modulation strategies. For general 8 segments SVPWM modulation sequence in the multilevel inverter, the inherent relationship between these two modulation methods have been researched, but the relationship between CBPWM and SVPWM in an arbitrary level sequence has not been obtained. To solve this problem, an in-depth study of the relationship between the multilevel SVPWM method and the CBPWM method has been made in this paper. By decomposing the modulation wave, and the SVPWM can be achieved by multi-modulation waves CBPWM. And the relationship between SVPWM and CBPWM in N level with an arbitrary number of segments sequence are obtained. Thus, through simple multi-modulation waves CBPWM strategy, less THD in the spectrum and higher DC voltage utilization switching sequences of multilevel inverters can be obtained. The simulation and experimental results illustrate that the relationship between CBPWM and SVPMM is correct.