The trial and error method is the conventional method for LCL parameter design. Its efficiency is low and it is difficult to obtain the optimal parameter. Furthermore, due to the lack of detailed analysis of the high-frequency harmonics in the inverter output voltage, the designed LCL filter cannot effectively filter them, resulting that the quality of the grid-connected current cannot fully meet IEEE 519 standard. Based on the above-mentioned problems, the high-frequency harmonics of inverter output voltage is analyzed in detail in this article, and the multiobjective optimization function, including five optimization objectives, is constructed. Combined with the particle swarm optimization, a screening method is proposed to realize the multiobjective optimization process. Under the proposed method, the LCL parameter, which happens to meet the requirement of IEEE 519 for the high-frequency harmonic distortion rate of the grid-connected current, can be obtained, and the greatest tradeoff of LCL filtering performance and filter cost is achieved. In addition, the proposed method considers the problem of weak grid and provides a complete engineering solution for LCL parameter design in different degrees of weak grid. Finally, the effectiveness and accuracy of the proposed design method are verified by contrast simulation and experiment.
18 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In the medium- and high-power grid-connected photovoltaic system, the controller bandwidth is constrained due to the low switching frequency. This issue limits the resonant frequency of the traditional proportional multiresonant (PMR) controller, and then makes it difficult to suppress the main lowfrequency harmonics in the grid-connected current. In addition, it is difficult for PMR to maintain good performance under the severe operating conditions, such as the grid voltage containing the resonant-frequency harmonic, the grid voltage sagging etc. Based on the above practical problems and on-site requirements, a novel first-order active-disturbance-rejection active-damping control strategy, based on the inverter-side current feedback (ICF-ADRC-AD) for LCL grid-connected inverter is proposed in this paper. The standard form of the system block diagram is deduced, the stability and immunity of the system are analyzed. Finally, the effectiveness and superiority of the proposed control strategy under different operating conditions are verified by simulation and experiment. The control strategy proposed in this paper improves the suppression effect of low-frequency total harmonic and resonance, and also improves the stability and immunity of the system.
31 January 2023 in IEEE Transactions on Power Electronics
In high-power grid-connected inverter for new energy power generation system, low switching frequency makes the control loop, LCL -filter resonant peak, and sideband harmonics generated by modulation coupled so that the parameter design of filter and controller affects each other. This increases the difficulty of design of filter parameters and controller parameters. To solve this problem, the accurate current harmonic calculation method based on the harmonic state-space model and considering switching frequency and control delay is proposed in this article first. Second, based on the above model, the parameter optimization process considering current harmonic distortion rate, filter cost, and so on is constructed. The integrated optimization design of filter and controller parameters of low-switching-frequency LCL grid-connected inverter is completed through intelligent algorithm. Thus, the filter cost is minimized on the premise that inverter performances meet the specific requirements. In addition, considering the nonideal characteristic of grid, a scheme of integrated parameter design that can adapt to the large-scale change of grid strength is proposed. Finally, the effectiveness of the proposed method and scheme is verified by simulation and experiment.
25 August 2022 in IEEE Transactions on Power Electronics
Under low-switching-frequency condition, there is harmonic coupling in grid-connected inverter. The harmonic state-space (HSS) modeling method is an effective means to analyze the output harmonic characteristics of inverter. When the switching frequency is low, the sampling/holding and control delay make the update of pulsewidth modulation pulses more untimely, which will have a non-negligible impact on system output. However, the current relevant research fails to take these factors into account in the HSS model. In addition, the existing work fails to thoroughly study the calculation and analysis methods of HSS model, and the relevant work is insufficient. Based on this, this article studies the closed-loop HSS model and its calculation and analysis methods of three-level grid-connected inverter considering the digitization impact. First, according to the different calculation and analysis methods of the HSS model of the grid-connected inverter, the methods considering the digitization impact are proposed, respectively. Second, according to the proposed method, the harmonic characteristics of low-switching-frequency grid-connected inverter are analyzed, and the necessity of considering the digitization impact is explained. Finally, the effectiveness and accuracy of the proposed HSS-model calculation and analysis methods considering the digitization impact are verified by simulation and experiment.
11 January 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The modified LCL (MLCL) is commonly applied in photovoltaic (PV) string inverters to suppress the leakage current and enhance the electromagnetic interference (EMI) performance of the grid current. However, the potential risk of resonance appears in the common mode (CM) loop, which was caused by the MLCL filter. In this article, the CM model of the inverter is first built considering the inductance saturation. It is found that the variable inductor brings phase margin decreasing problem and additional resonance points in the CM loop. To suppress the CM resonance (CMR), novel passive and active damping strategies are explored in this article. The improved passive damping (IPD) strategy is realized by introducing a paralleled RC unit, which greatly reduces the damping resistor losses without affecting the damping performance. Besides, a novel active damping (NAD) strategy is proposed to compensate the time delay and to raise the phase margin. Moreover, considering the gradient mutation issue brought by the discontinuous pulsewidth modulation (DPWM) scheme, an antisaturation PWM (ASPWM) scheme is applied to eliminate the oscillation. Finally, experiments are conducted on an 80-kW PV string inverter. After applying the proposed CMR damping strategy with the ASPWM scheme, CMR is fully eliminated in the whole power range despite the grid condition.
7 July 2022 in IEEE Transactions on Industrial Electronics
To study the frequency coupling effect (FCE) of nonlinear inductors in the frequency domain, in this article, a multifrequency small-signal model is developed for the modified LCL -filtered grid-connected inverter. This model is realized by extracting sideband coupling units out of the harmonic state-space (HSS) model and superposing them to the perturbation frequency loop. Compared with the complicated reductant HSS model, the proposed multifrequency model provides an intuitive, efficient, and accurate way to describe the system. Besides, notions in classical control theory can be directly utilized with the multifrequency model. With this model, the current control loop of the inverter is studied. Besides, by introducing a simplified linear time-invariant (LTI) small-signal model (the FCE is ignored), it is found that the FCE effect is nonnegligible, especially in the frequency range around resonance points, which affects the stability of the differential-mode resonance (DMR) and common-mode resonance (CMR). The proposed multifrequency model accurately predicts the DMR and CMR stability, while the simplified LTI model fails. Furthermore, damping strategies are developed to suppress the DMR and CMR. Finally, simulations and experiments based on a 228 kW photovoltaic inverter are conducted to verify the analytical result.