Gabriel Blaj

Gabriel Blaj

Auto-generated profile, based on publicly available information

Gabriel Blaj


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
RBRafael Ballabriga
Rafael Ballabriga
JAJ Alozy
J Alozy
GBG Blaj
G Blaj
MCM Campbell
M Campbell
MFMichael Fiederle
Michael Fiederle
WWW Wong
W Wong

20 July 2004 in Journal of Comparative Physiology A
Verified
Journal Article
Closed access
PDF file
GBG. Blaj
G. Blaj
JHJ. H. van Hateren
J. H. van Hateren

21 April 2015 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
GBGabriel Blaj
Gabriel Blaj
PCPietro Caragiulo
Pietro Caragiulo
GCGabriella Carini
Gabriella Carini
SCSebastian Carron
Sebastian Carron
ADAngelo Dragone
Angelo Dragone
MWMatt Weaver
Matt Weaver
Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

19 May 2016 in The Journal of Physical Chemistry Letters
Verified
Journal Article
Open access
Claudiu StanClaudiu Stan
Claudiu Stan
PWPhilip R. Willmott
Philip R. Willmott
HSHoward A. Stone
Howard A. Stone
JKJason E. Koglin
Jason E. Koglin
MLMengning Liang
Mengning Liang
FDFranz-Josef Decker
Franz-Josef Decker
Most experimental studies of cavitation in liquid water at negative pressures reported cavitation at tensions significantly smaller than those expected for homogeneous nucleation, suggesting that achievable tensions are limited by heterogeneous cavitation. We generated tension pulses with nanosecond rise times in water by reflecting cylindrical shock waves, produced by X-ray laser pulses, at the internal surface of drops of water. Depending on the X-ray pulse energy, a range of cavitation phenomena occurred, including the rupture and detachment, or spallation, of thin liquid layers at the surface of the drop. When spallation occurred, we evaluated that negative pressures below −100 MPa were reached in the drops. We model the negative pressures from shock reflection experiments using a nucleation-and-growth model that explains how rapid decompression could outrun heterogeneous cavitation in water, and enable the study of stretched water close to homogeneous cavitation pressures.

17 April 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
TDTim B. van Driel
Tim B. van Driel
SNSilke Nelson
Silke Nelson
RARebecca Armenta
Rebecca Armenta
GBGabriel Blaj
Gabriel Blaj
SBStephen Boo
Stephen Boo
MWMatt Weaver
Matt Weaver
The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel−1 pulse−1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

1 January 2011 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
RBRafael Ballabriga
Rafael Ballabriga
GBG Blaj
G Blaj
MCM Campbell
M Campbell
MFMichael Fiederle
Michael Fiederle
DGDominic Greiffenberg
Dominic Greiffenberg
WWW Wong
W Wong